Holographic gratings for spectrographic applications: Study of abberations
A computer program was developed that determines the optimum holographic grating recording parameters as a function of optical instrumental parameters and desired wavelength range for Seya-Namioka monochromator mountings. The theory and basic equations for designing holographic concave gratings such that minimization of aberrations of astigmatism or coma over a desired wavelength range may be achieved are presented. The computer program is described, including all of the subroutines. The input data, definitions of terms, and data card description are presented. An example is summarized for using the program and the output data is described in detail.