Abstract

As proposed, the main effort in this project is the development of software capable of performing real-time monitoring of micro-seismic activity recorded by an array of sensors deployed around an EGS. The main milestones are defined by the development of software to perform the following tasks: • Real-time micro-earthquake detection and location • Real-time detection of shear-wave splitting • Delayed-time inversion of shear-wave splitting These algorithms, which are discussed in detail in this report, make possible the automatic and real-time monitoring of subsurface fracture systems in geothermal fields from data collected by an array of seismic sensors. Shear wave splitting (SWS) is parameterized in terms of the polarization of the fast shear wave and the time delay between the fast and slow shear waves, which are automatically measured and stored. The measured parameters are then combined with previously measured SWS parameters at the same station and used to invert for the orientation (strike and dip) and intensity of cracks under that station. In addition, this grant allowed the collection of seismic data from several geothermal regions in the US (Coso) and Iceland (Hengill) to use in the development and testing of the software.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rial, J A, Lees, J. 2009-03-31. Final technical report. https://doi.org/10.2172/982094

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY↗