DOE OSTI · 972366
MIPP Plastic Ball electronics upgrade
Abstract
An upgrade electronics design for Plastic Ball detector is described. The Plastic Ball detector was a part of several experiments in the past and its back portion (proposed to be used in MIPP) consists of 340 photomultipliers equipped with a sandwich scintillator. The scintillator sandwich has fast and slow signal component with decay times 10 ns and 1 {micro}s respectively. The upgraded MIPP experiment will collect up to 12,000 events during each 4 second spill and read them out in {approx}50 seconds between spills. The MIPP data acquisition system will employ deadtime-less concept successfully implemented in Muon Electronics of Dzero experiment at Fermilab. An 8-channel prototype design of the Plastic Ball Front End (PBFE) implementing these requirements is discussed. Details of the schematic design, simulation and prototype test results are discussed.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Baldin, Boris. 2009-01-01. MIPP Plastic Ball electronics upgrade. https://doi.org/10.1016/j.nima.2009.05.096. https://engineeringpapers.com/record/osti%3A972366/mipp-plastic-ball-electronics-upgrade