Engineering Papers⌕ Search

DOE OSTI · 1992841

Charge sharing in pixelated semiconductor sensors

Abstract

The charge sharing between neighboring pixels in pixelated sensors can be used to measure particle or x-ray coordinates with accuracy better than the pixel pitch. The accurate model of the charge distribution shape is essential to achieve ultimate coordinate accuracy. The charge sharing is caused by charge carriers' diffusion on the path from the generation point to pixels. This paper is focused on the diffusion of the initially compact charge cloud in the field free region. The diffusion equation solutions are obtained using separation of variable and Fourier synthesis method for different initial conditions and resulting charge distributions are integrated over pixel areas. In conclusion, the look up table containing pre-calculated values for pixel charge fractions is proposed to speed up numerical calculations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kotov, Ivan V., Li, Jiemin, Pelliciari, Jonathan, Bisogni, Valentina. 2022-11-11. Charge sharing in pixelated semiconductor sensors. https://doi.org/10.1016/j.nima.2022.167718

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗