Washington River Protection Solutions, LLC (WRPS) is planning to conduct repairs in the Liquid Effluent Retention Facility (LERF), and prior to conducting this work they will re-evaluate the hazard category designation for LERF. As part of this evaluation, WRPS needs estimates of the release fraction of potential accidental sprays, because a spray release is a potential bounding accident. Pacific Northwest National Laboratory previously developed a conservative correlation for the cumulative generation rate (volume per time) of aerosol droplets less than or equal to specific sizes from spray releases as a function of the spray pressure, orifice area, and droplet diameter. To obtain release fraction estimates from the conservative generation rate correlation, the correlation needs to be recast by dividing the aerosol generation rate by the flow rate of a spray. In the current study, a conservative release fraction correlation was developed from the conservative aerosol generation rate correlation developed previously by dividing the generation rate correlation by the flow rate of a spray using an orifice flow rate equation and then this correlation was adjusted to be conservative. Test data were also extrapolated to a lower pressure than the lowest pressure tested (100 psig) for the spray data used for developing the previous conservative generation rate correlation. The new conservative release fraction correlation was then used to predict release fractions of respirable droplets (droplets = 10 µm) for four specific pipes that are part of LERF.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gauglitz, Phillip A., Daniel, Richard C.. 2020-02-14. Conservative Release Fraction Correlation for Spray Releases. https://doi.org/10.2172/1765889

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2025

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2025. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of the DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, the evaluation of data collected in 2025 continued to indicate that WVDP activities posed no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗