Engineering Papers⌕ Search

Engineering topics

Daniel, Richard C.

Publications and source records attributed to Daniel, Richard C..

At least 19 records

Simulant Development of Potential 200 West Area Waste Feeds

Preliminary planning for retrieval, qualification, and pretreatment of waste in Hanford’s 200 West Area (200W) has begun as part of the West Area Risk Management project. Experimental studies to technically mature pretreatment process operations will likely be needed because of the uniqueness of 200W waste. Pacific Northwest National Laboratory formulated five simulants to represent 200W-qualified feed based on the preliminary flowsheet provided by Washington River Protection Solutions, LLC. The simulant recipes were devised using applicable historical information as a reference point to support the use of the flowsheet waste vectors, which were combined into five distinct groups. These five groups formed the basis for the liquid composition targets that were adapted into recipes using charged-balanced salt species. The liquid phase recipes were batched in 1-L quantities and analyzed at Pacific Northwest National Laboratory. Once confirmed to be stable, the liquid solutions were tested for compatibility with candidate solid components. Specific solid components were recommended based on cross-examining the proposed solid phases in the flowsheet with relevant data from the literature. Mixtures of solid components were added to aliquots of the liquid batches and sub-sampled to measure particle size distribution. The measured distribution was compared to independently created benchmark distributions appropriate for each simulant. This process was iterated until a solid phase composition that resulted in a representative particle size distribution was found. After the final compositions were confirmed, a suite of chemical and physical characterization data was collected. This report describes the simulant basis, formulation methodology, laboratory measurements, and data collected for the recipes recommended to represent 200W waste feeds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗

Filtration of Hanford Tank 241-AN-107 Supernatant at 16 °C

Approximately 9 liters of supernatant from Hanford waste tank 241-AN-107 was delivered by Washington River Protection Solutions to the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory. The thirty-six AN-107 sample bottles consisted of six sets of six samples, with each set pulled from a unique tank sampling level. Prior to testing, samples from each level were composited to provide nominally level-independent feed for dead end filtration and ion exchange testing. The composited 241-AN-107 supernatant was chilled to 16 °C for 1 week prior to testing. Filtration testing was then conducted using a backpulse dead-end filter (BDEF) system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the RPL. The purpose of this testing is to a) demonstrate dead-end filtration (DEF) of AN-107 feed at reduced temperature to obtain prototypic tank side cesium removal (TSCR) flux rates and identify issues that may impact filtration after dilution to 5.5M Na, and b) provide feed for a follow on ion exchange unit operation. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 . During filtration the differential pressure required to effect filtration at 0.065 gpm/ft 2 was slow to increase for most of the filtration campaign. After all the feed bottles had been pumped into the slurry reservoir, the bottoms of the bottles were added to the reservoir and transmembrane pressure (TMP) reached 2.0 psid (the TSCR action limit). The prototypic filter cleaning process was unable to effectively restore filter performance, and cleaning with oxalic acid was required before flow through the filter could be restored. This indicates that the Media Grade 5 filter may require an alternative cleaning protocol when processing AN-107 supernatant. After completing filtration of the AN-107 feed, the filter was cleaned. Solids concentrated from the backpulse solutions were composed of natrophosphate, Mn-Fe phases, and fluoro-natrophosphate that occurred as particle agglomerates. The individual particles were in some cases 100s of micrometers across which is consistent with prior observations from AN-107 supernate waste characterizations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated SEM analysis of particles in Hanford tank waste

Multiple bench-scale filtration campaigns of Hanford tank waste supernatant on a backpulseable dead-end filtration skid have provided greater insight into the solids that cause fouling and reduce filter performance. The solids collected during each campaign were concentrated from the backpulse solutions and examined using automated particle analysis (APA) methods with scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDS), to categorize particle types and their morphological characteristics. Finally, we show that with APA, thousands of particles can be analyzed that can provide accurate insight into the phases that may be impacting filter performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation (Rev.1)

The Hanford Tank Waste Treatment and Immobilization Plant Low Activity Waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of discovering that sampling locations do not meet the qualification criteria on the full-scale stacks. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. For this analysis, the range of qualified flow rates listed is conservatively based on the average DV through 6 DV for LV-S1, LV-S2, and LV-C2, and 1/3 DV to 3 DV for LV-S3. Table S1 lists the operating flow rates along with the conservative lower and upper qualified stack flow rates for each of the LAW facility stacks. For each stack, the operating flow is below the upper qualified stack.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of the immobilized low-activity waste glass corrosion model to the static dissolution of 24 statistically-designed alkali-borosilicate waste glasses

Glass corrosion models that capture the complex mechanisms of the glass-water reaction enable the prediction of nuclear waste glass durability in disposal scenarios. Parameterization of such models is challenging because of the need to capture changes in corrosion behavior with time, reaction conditions, and glass composition. In this report we describe and employ the immobilized low activity waste (ILAW) glass corrosion model (IGCM) in geochemical simulations of static dissolution tests, at two temperatures (40 °C and 90 °C), for a matrix of 24 enhanced low activity waste (eLAW) glasses statistically designed to cover a processable composition space defined by 8 major glass components (Al 2 O 3 , B 2 O 3 , CaO, Na 2 O, SiO 2 , SnO 2 , ZrO 2 , and Others as defined in the text). The IGCM includes a first-order chemical affinity term and an ion-exchange term that represents the net exchange of Na+ ions in the pristine glass with protons in aqueous solution. Constant, time-dependent, and time- and pH-dependent functional forms of the ion-exchange term are evaluated to reproduce the change in corrosion behavior with time in saturated, static dissolution tests. The agreement with measured aqueous concentrations of the main glass components (B, Na, and Si) improved significantly upon addition of a time-dependent term, which therefore constitutes a simple representation of the glass-water reaction progress. Due to the limited changes in pH in the static dissolution tests, past a short initial period of rapid increase, addition of a pH dependent term did not appreciably improve the fits, indicating that comprehensive model parameterization requires more than one type of glass corrosion test to capture a wide range of solution chemistries. IGCM parameters were found to be dependent on glass composition, and the parameter sets generated in this work will enable the development of composition–parameter correlation models that offer the promise of predicting IGCM parameters, and thus glass corrosion behavior, solely based on glass composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY 23 Filtration of Hanford Tank 241-SY-101 Supernatant at 16 °C

Approximately 9 liters of supernatant from Hanford waste tank 241-SY-101 was delivered by Washington River Protection Solutions to the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory. The thirty-six SY-101 sample bottles were comprised of six sets of six samples, with each set pulled from a unique tank sampling level. Prior to testing, samples from each level were composited to provide nominally level-independent feed for dead end filtration and ion exchange testing. The composited 241-SY-101 supernatant was chilled to 16 °C for 1 week prior to testing. Filtration testing was then conducted using a backpulse dead-end filter (BDEF) system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the RPL. This was done to provide waste processing benchmarks for 200 West Area wastes in the West Area Risk Management project. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 . During filtration of the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased little over the filtration campaign and never reached 2 psid (the Tank Side Cesium Removal system action limit). This indicates that the Media Grade 5 filter should perform well when processing SY-101 supernatant. After completing filtration of the SY-101 feed, the filter was cleaned. Solids concentrated from the backpulse solutions displayed calcium phosphate, aluminum oxides, aluminum-chromium nanoparticle agglomerates. Electron diffraction was used to determine the types of phases that were present in the solids. Most of the phases found were only weakly crystalline, possibly owing to their rapid precipitation during the process water treatment. The identifications of the phases therefore are tentative.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiscal Year 2023 Filtration of Hanford Tank 241-AP-105 Supernatant at 16 °C

Approximately 9 liters of supernatant from Hanford waste tank 241-AP-105 was delivered by Washington River Protection Solutions to the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory. The as-received AP-105 waste was diluted with process water (Columbia River water) from approximately 8.7 M sodium (nominal tank concentration) and partitioned into a batch of 7 M sodium and a batch of 5.5 M sodium. Dilution increased the combined volume of the two batches to approximately 7.8 liters of 7 M Na feed and 4.4 liters of 5.5 M Na feed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rheology of a Wet Waste Feedstock

The current study provides rheological characterization of a representative HTL feedstock, Wet Waste Feedstock # 22 (WW22), as a function of HTL-prototypic temperature and shear rates. Feed WW22 is derived from a regionally representative blend of food, waste water sludges, and FOG (fats, oils, and greases). Rheological characterization of WW22 as a function of temperature provides, in part, key information for development and economic assessment of HTL wet waste slurry handling and heating operations, which may facilitate improved design rigor and optimization of HTL unit operations.

09 BIOMASS FUELS↗

PNNL FY 2022 Sibling Pin Testing Results

This report presents the results of testing two rods after heat treatment at 400C for 8 hours and compares to the results from FY 2021 of similar rods that were tested as baseline. The heat treatment resulted in a decrease in yield stress.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fiscal Year 2022. Filtration of Hanford Tank 241-AP-101 Supernatant at 16 °C

Bench-scale filtration testing of ~9 liters of supernatant from Hanford waste tank 241-AP-101, chilled to 16 °C, was conducted using a backpulse dead-end filter (BDEF) filtration system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. This was done to assess the performance of the anticipated third feed to the Tank Side Cesium Removal (TSCR) system. The as-received samples were diluted to the target sodium concentration and transferred to 1.5-liter polyethylene bottles and held at 16 °C for approximately 1 week prior to filtration. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 to match the prototypic operation of the TSCR system. During filtration, the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased little over the filtration campaign and never reached 2 psid (the TSCR action limit). This indicates that the TSCR filter should perform well when processing AP-101 supernatant. After completing filtration of the AP-101 feed, the filter was cleaned. Solids concentrated from the backpulse solutions displayed sodium nitrate-type phases, aluminum and silicon phases reported as cancrinite or nitrate-cancrinite, a mixed chromium-aluminum oxide, iron oxides, and Ca-bearing phases (calcite). Scanning electron microscopy analyses showed that the average particle size was 0.5 micron.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of dilution-induced precipitates on the filtration of Hanford liquid tank wastes

To facilitate its vitrification, a portion of the radioactive wastes currently stored at the Hanford Site will be staged and treated using tank-side operations to render their chemistry compliant with the requirements of Hanford’s low-activity waste vitrification facility. Initial sampling of staged feeds indicates that process-water dilution, used to reduce waste feed sodium content to levels acceptable for vitrification (5–6 M Na), may cause precipitation of fine, difficult to settle solids that could affect downstream tank-side filtration and ion-exchange. However, dilution-induced precipitation has not been demonstrated under controlled, rigorous laboratory conditions. This paper presents a set of qualitative and quantitative assessments of dilution-induced precipitation using a nonradioactive, Hanford Tank AP-105 simulated waste. Further, these studies found that dilution of AP-farm waste simulants induced precipitation of up to 150 ppm solids, regardless of whether dilution was done with process water (which contains, among other analytes, naturally occurring Ca and Mg) or deionized water. Naturally occurring process-water analytes appeared to accelerate the rate (and possibly extent) of precipitation. Filtration of diluted waste simulants also found that the precipitated solids challenged prototypic tank-side filter operations; however, the impact to filtration performance was readily managed through waste staging settle/decant operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of zeolite type, temperature, and pH on Stage III glass alteration behavior for two nuclear waste glasses

We report long-term laboratory scale static alteration tests (up to 1500 d) were conducted on two low-activity waste glasses (LAWA44 and IDF18-A161) at S/V = 2000 m –1 . Tests were seeded with either analcime, clinoptilolite, zeolite P1, or zeolite P2 to induce Stage III glass alteration behavior. The effect of several parameters on glass Stage III behavior was studied with consideration of several variables, including temperature (22 °C – 90 °C) and pH (floating or initially set using KOH at values from 9.5 to 11.5). Temporal solution data and solids characterization at the end of the experiments are reported. Solution data demonstrated the occurrence of a sustained rate acceleration at temperatures down to 40 °C and the activation energy for these Stage III rates was determined for both glasses. Three major secondary phases were identified at the end of the experiments for both glasses: zeolite P1, zeolite P2, and/or analcime (along with minor phases: zeolites, clays, carbonates). The identification of the crystalline phases at the end of the experiment often differed from the zeolite seed phase. In addition, the use of the Avrami equation showed unimpeded zeolite growth (3-dimensional) in certain conditions, suggesting that in certain conditions the glass dissolution rate is controlled by zeolite formation kinetics whereas in other conditions the glass corrosion process impeded zeolite formation kinetics. The morphological evolution of the samples revealed the growth of the zeolites which completely fill the intergranular space in the powder bed. These results are discussed with regards to previous seeded and unseeded Stage III dissolution rate experiments performed on low- and high-activity nuclear waste glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PNNL FY2021 Sibling Pin Testing Results

The post-irradiation examination, axial tensile, burst, and four-point bend testing results of the first two sibling pins, 6U3/L8 and 5K7/P2 are presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗