Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PLSS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

SWME

New Lithium-ion Polymer Battery for the Extravehicular Mobility Unit Suit

The Extravehicular Mobility Unit (EMU) suit currently has a silver-zinc battery that is 20.5 V and 45 Ah capacity. The EMU's portable life support system (PLSS) will draw power from the battery during the entire period of an EVA. Due to the disadvantages of using the silver-zinc battery in terms of cost and performance, a new high energy density battery is being developed for future use, The new battery (Lithium-ion battery or LIB) will consist of Li-ion polymer cells that will provide power to the EMU suit. The battery design consists of five 8 Ah cells in parallel to form a single module of 40 Ah and five such modules will be placed in series to give a 20.5 V, 40 Ah battery. Charging will be accomplished on the Shuttle or Station using the new LIB charger or the existing ALPS (Air Lock Power Supply) charger. The LIB delivers a maximum of 3.8 A on the average, for seven continuous hours, at voltages ranging from 20.5 V to 16.0 V and it should be capable of supporting transient pulses during start up and once every hour to support PLSS fan and pump operation. Figure 1 shows the placement of the battery in the backpack area of the EMU suit. The battery and cells will undergo testing under different conditions to understand its performance and safety characteristics.

Jeevarajan, J. A.

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

Michael Lewandowski

Advanced Materials Testing Plan for the Space Suit Portable Life Support System

The Space Suit Portable Life Support System (PLSS) has a tight mass requirement to meet while also meeting other requirements for supporting a crewmember in space, on the Moon, or on Mars. To meet these requirements, atypical materials must be considered to close the mass budget allocations. However, many of these materials and processes are relatively new and untested. Therefore, initial analysis and testing of some new and advanced processes have been conducted following a roadmap presented last year. This material testing has focused primarily on thermoplastics, both additively manufactured and machined, to assess plating and fastening operations that will be required. These processes will provide additional strength and shielding capability typically only achieved with metallics. This testing has also helped to define a forward plan to certify these materials and processes for critical spaceflight applications. This report will review testing plated thermoplastics both for strength and thermal properties. It will also review fastener and fastening options and look at insert and fastener testing. It will also review state-of-the-art methods being considered elsewhere and some additional testing being conducted. Using the testing results researched here, there will be recommendations on applications for each of these types of methods going forward.

Ryan Ogilvie

Advanced Materials Testing Plan for the Space Suit Portable Life Support System

The Space Suit Portable Life Support System (PLSS) has a tight mass requirement to meet while also meeting other requirements for supporting a crewmember in space, on the Moon, or on Mars. To meet these requirements, atypical materials must be considered to close the mass budget allocations. However, many of these materials and processes are relatively new and untested. Therefore, initial analysis and testing of some new and advanced processes have been conducted following a roadmap presented last year. This material testing has focused primarily on thermoplastics, both additively manufactured and machined, to assess plating and fastening operations that will be required. These processes will provide additional strength and shielding capability typically only achieved with metallics. This testing has also helped to define a forward plan to certify these materials and processes for critical spaceflight applications. This report will review testing plated thermoplastics both for strength and thermal properties. It will also review fastener and fastening options and look at insert and fastener testing. It will also review state-of-the-art methods being considered elsewhere and some additional testing being conducted. Using the testing results researched here, there will be recommendations on applications for each of these types of methods going forward.

Ryan Ogilvie

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell