NASA NTRS · 19910061172
High-power hydrogen arcjet performance
Abstract
A hydrogen arcjet was operated at power levels ranging from 5 to 30 kW with three different nozzle geometries. Test results using all three nozzle geometries are reported and include variations of specific impulse with flow rate, and thrust with power. Geometric variables investigated included constrictor diameter, length, and diverging exit angle. The nozzle with a constrictor diameter of 1.78 mm and divergence angle of 20 deg was found to give the highest performance. A specific impulse of 1460 s was attained with this nozzle at a thrust efficiency of 29.8 percent. The best efficiency measured was 34.4 percent at a specific impulse of 1045 s. Post test examination of the cathode showed erosion after 28 hours of operation to be small, and limited to the conical tip where steady state arc attachment occurred. Each nozzle was tested to destruction.
Keep this discovery
Explore connections, maps & timelines
Haag, Thomas W., Curran, Francis M.. 1991-06-01. High-power hydrogen arcjet performance. https://ntrs.nasa.gov/citations/19910061172
Cite the original work for its findings. Save a collection to share your selection of sources.