Engineering PapersSearch

NASA NTRS · 19820039498

Partial discharge testing under direct voltage conditions

Abstract

DC partial discharge (PD) (corona) testing is performed using a multichannel analyzer for pulse storing, and data is collected during increase of voltage and at quiescent voltage levels. Thus high voltage ceramic disk capacitors were evaluated by obtaining PD data interspersed during an accelerated life test. Increased PD activity was found early in samples that later failed catastrophically. By this technique, trends of insulation behavior are revealed sensitively and nondestructively in high voltage dc components.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bever, R. S., Westrom, J. L.. 1982-01-01. Partial discharge testing under direct voltage conditions. https://ntrs.nasa.gov/citations/19820039498