Stable hydraulic pressure regulator

Abstract

Neither sensing line restrictors nor frictional dampers are required for stability. Analysis presents method by which stability margin, response, and droop magnitude can be incorporated during design of direct-acting hydraulic pressure regulators.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gold, H.. 1979-01-01. Stable hydraulic pressure regulator. https://ntrs.nasa.gov/citations/19780000417