NASA NTRS · 19740044690
The M.I.T. Blowdown compressor facility
Abstract
A blowdown compressor test facility has been developed which allows time-resolved aerodynamic testing of full-scale transonic compressor rotors at low cost. The rotor is brought to speed in vacuum, a diaphragm is opened, and the test gas is allowed to flow for a time of the order of 0.1 sec, during which the rotor is driven by its own inertia. Both 'steady-state' performance evaluation and detailed time resolution of the flow on the blade-passing time scale have been demonstrated for a two-ft-diam transonic rotor with a tangential Mach number of 1.2 and a nominal pressure ratio of 1.6. The steady-state performance as determined in the experiments includes an efficiency of 0.92 and a pressure ratio of 1.55 at design speed. The time-resolved measurements include the combination tone structure in the upstream flow field, resolved both axially and radially, and the wake structure downstream of the rotor, also resolved both radially and axially.
Keep this discovery
Explore connections, maps & timelines
Kerrebrock, J. L., Epstein, A. H., Haines, D. M., Thompkins, W. T.. 1974-03-01. The M.I.T. Blowdown compressor facility. https://ntrs.nasa.gov/citations/19740044690
Cite the original work for its findings. Save a collection to share your selection of sources.