Abstract

Test results for full scale simulated surface insulation tiles on both the tunnel wall and in the free stream, for in-line and staggered tile orientations, are summarized as follows: (1) The staggered tile orientation has heating on the forward face which is a factor of 4.5 times higher than the heating to the forward face of the in-line tile orientation; (2) the longitudinal gap heating was the highest for the 0.3175 cm gap and the lowest for the 0.1587 cm gap; and (3) there was an order of magnitude decrease in the heating on the forward face of a spanwise gap when the gap size was decreased from 0.3175 cm to 0.1587 cm.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Johnson, C. B.. 1973-09-01. Interference Heating to Cavities Between Simulated RSI Tiles. https://ntrs.nasa.gov/citations/19730024766