NASA NTRS ยท 19730024766
Interference Heating to Cavities Between Simulated RSI Tiles
Abstract
Test results for full scale simulated surface insulation tiles on both the tunnel wall and in the free stream, for in-line and staggered tile orientations, are summarized as follows: (1) The staggered tile orientation has heating on the forward face which is a factor of 4.5 times higher than the heating to the forward face of the in-line tile orientation; (2) the longitudinal gap heating was the highest for the 0.3175 cm gap and the lowest for the 0.1587 cm gap; and (3) there was an order of magnitude decrease in the heating on the forward face of a spanwise gap when the gap size was decreased from 0.3175 cm to 0.1587 cm.
Keep this discovery
Explore connections, maps & timelines
Johnson, C. B.. 1973-09-01. Interference Heating to Cavities Between Simulated RSI Tiles. https://ntrs.nasa.gov/citations/19730024766
Cite the original work for its findings. Save a collection to share your selection of sources.