Engineering PapersSearch

Engineering topics

Johnson, C. B.

Publications and source records attributed to Johnson, C. B..

At least 19 records

Streak camera receiver definition study

Detailed streak camera definition studies were made as a first step toward full flight qualification of a dual channel picosecond resolution streak camera receiver for the Geoscience Laser Altimeter and Ranging System (GLRS). The streak camera receiver requirements are discussed as they pertain specifically to the GLRS system, and estimates of the characteristics of the streak camera are given, based upon existing and near-term technological capabilities. Important problem areas are highlighted, and possible corresponding solutions are discussed.

Johnson, C. B.

Detecting Boundary-Layer Transition In Cold Environments

Transition-detection study conducted in Langley 0.3-Meter Transonic Cryogenic Tunnel, using specialized hot-film system designed specifically for use in cryogenic wind tunnels. Quantitative transition-location data obtained at nearly cryogenic conditions, 360 degree R (200 K) represents first definitive transition Reynolds numbers obtained in cryogenic wind tunnel. Multichannel data-acquisition system processes data from 40 hot-film sensors by use of desktop computer. Concept enables on-line determination of boundary-layer transition in such cryogenic wind tunnels as National Transonic Facility.

Johnson, C. B.

High Reynolds number tests of the CAST-10-2/DOA 2 transonic airfoil at ambient and cryogenic temper ature conditions

The transonic airfoil CAST 10-2/DOA 2 was investigated in several major transonic wind tunnels at Reynolds numbers ranging from Re=1.3 x 10(exp 6) to 45 x 10(exp 6) at ambient and cryogenic temperature conditions. The main objective was to study the degree and extent of the effects of Reynolds number on both the airfoil aerodynamic characteristics and the interference effects of various model-wind-tunnel systems. The initial analysis of the CAST 10-2 airfoil results revealed appreciable real Reynolds number effects on this airfoil and showed that wall interference can be significantly affected by changes in Reynolds number thus appearing as true Reynolds number effects.

Stanewsky, E.

Comparisons of boundary-layer transition measurement techniques in the Langley Unitary Plan wind tunnel

Four different boundary-layer transition detection techniques, namely liquid crystals, very thin hot films, IR photography, and an optical interferometer, were compared using the same flat plate model for the same tunnel conditions. The comparisons, conducted at NASA-Langley, involved not only their sensitivity to transition but also their ease of use. The thin films, as expected, gave excellent quantitative information and were used as the standard for evaluating the other techniques. Both the liquid crystals and IR photography were able to detect transition before the boundary-layer intermittency factor had reached 50 percent. The optical interferometer was unsuccessful. Conditions sampled included a range of Mach numbers from 1.5 to 2.5 and unit Reynolds numbers from 1.0 to 4.0 million/foot.

Hall, R. M.

Wind tunnel-sidewall-boundary-layer effects in transonic airfoil testing-some correctable, but some not

The need to correct transonic airfoil wind tunnel test data for the influence of the tunnel sidewall boundary layers, in addition to the wall accepted corrections for the analytical investigation was carried out in order to evaluate sidewall boundary layer effects on transonic airfoil characteristics, and to validate proposed correction and the limit to their applications. This investigation involved testing of modern airfoil configurations in two different transonic airfoil test facilities, the 15 x 60 inch two-dimensional insert of the National Aeronautical Establishment (NAE) 5 foot tunnel in Ottawa, Canada, and the two-dimensional test section of the NASA Langley 0.3 m Transonic Cryogenic Tunnel (TCT). Results presented included effects of variations in sidewall-boundary layer bleed in both facilities, different sidewall boundary layer correction procedures, tunnel-to tunnel comparisons of correcte results, and flow conditions with and without separation.

Lynch, F. T.

Heating requirements and nonadiabatic surface effects for a model in the NTF cryogenic wind tunnel

A theoretical study has been made of the severity of nonadiabatic surface conditions arising from internal heat sources within a model in a cryogenic wind tunnel. Local surface heating is recognized as having an effect on the development of the boundary layer, which can introduce changes in the flow about the model and affect the wind tunnel data. The geometry was based on the NTF Pathfinder I wind tunnel model. A finite element heat transfer computer code was developed and used to compute the steady state temperature distribution within the body of the model, from which the surface temperature distribution was extracted. Particular three dimensional characteristics of the model were represented with various axisymmetric approximations of the geometry. This analysis identified regions on the surface of the model susceptible to surface heating and the magnitude of the respective surface temperatures. It was found that severe surface heating may occur in particular instances, but could be alleviated with adequate insulating material. The heat flux through the surface of the model was integrated to determine the net heat required to maintain the instrumentation cavity at the prescribed temperature. The influence of the nonadiabatic condition on boundary layer properties and on the validity of the wind tunnel simulation was also investigated.

Macha, J. M.

A transition detection study using a cryogenic hot film system in the Langley 0.3-meter transonic cryogenic tunnel

A transition detection study was conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT) using a specialized hot film system designed specifically for use in cryogenic wind tunnels. The quantitative transition location data obtained at near cryogenic conditions, 360 deg R (200K) represents the first definitive transition Reynolds numbers obtained in a cryogenic wind tunnel. The model was tested at both adiabatic and nonadiabatic wall conditions with a wall-to-total temperature ratio as low as 0.47. The test results indicated an improved technique for hot-film installation and a modified data acquisition system would allow the on-line determination of the location of boundary layer transition in cryogenic wind tunnels, such as the U.S. National Transonic Facility.

Johnson, C. B.

Flow diagnostics and visualization in wind tunnels and flight

The Langley Research Center has a concentrated and directed effort under way to develop both conventional and non-intrusive diagnostic instrumentation. These instruments are being developed to operate over large Mach number, total temperature, and total pressure ranges. Efforts are being made to evaluate the measurements made by the various instruments to determine the most accurate and reliable instrument to be used under a given flow environment. Although only one flow visualization technique was described, there are many different types presently being used at Langley Research Center.

Stainback, P. C.

A description of the active and passive sidewall-boundary-layer removal systems of the 0.3-meter transonic cryogenic tunnel

Results are presented for an operational checkout and shakedown of the active sidewall-boundary-layer removal system newly installed in the Langley 0.3-meter Transonic Cryogenic Tunnel (0.3-m TCT). Prior to the installation of this active removal system, the sidewall-boundary layer was removed passively by exhausting directly to the atmosphere (i.e., no reinjection). With the active removal system using the reinjection compressor, the removal capability is greatly expanded to cover the entire operating envelope of the 0.3-m TCT. Details of the active removal system are presented including the compressor reinjection circuit, the compressor pressure ratio/surge control, and the compressor recirculation loop. The control logic and features of the compressor surge control are explained. Initial tests covering critical operating conditions show mass flow removal rates of about 5 percent at lower Mach numbers can be obtained with the active system. Measured performance characteristics of the compressor are presented. As part of the validation of the active system, limited airfoil tests were made using the new system.

Johnson, C. B.

A summary of Reynolds number effects on some recent tests in the Langley 0.3-meter transonic cryogenic tunnel

Reynolds number effects noted from selected test programs conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT) are discussed. The tests, which cover a unit Reynolds number range from about 2.0 to 80.0 million per foot, summarize effects of Reynolds number on: (1) aerodynamic data from a supercritical airfoil, (2) results from several wall interference correction techniques, and (3) results obtained from advanced, cryogenic tests techniques. The test techniques include: (1) use of a cryogenic sidewall boundary layer removal system, (2) detailed pressure and hot wire measurements to determine test section flow quality, and (3) use of a new hot film system suitable for transition detection in a cryogenic wind tunnel. The results indicate that Reynolds number effects appear most significant when boundary layer transition effects are present and at high lift conditions when boundary layer separation exists on both the model and the tunnel sidewall.

Johnson, C. B.

Dynamic measurement of total temperature, pressure and velocity in the Langley 0.3-meter transonic cryogenic tunnel

There is theoretical and experimental evidence which indicates that a sudden or step change in the rate at which the liquid nitrogen is injected into the circuit of a cryogenic wind tunnel can cause a temperature front in the flow for several tunnel circuit times. A temperature front, which occurs at intervals equal to the circuit time, is a sudden increase or decrease in the temperature of the flow followed by a nearly constant temperature. Since these fronts can have an effect on the control of the tunnel as well as the time required to establish steady flow conditions in the test section of cryogenic wind tunnel, tests were conducted in the settling chamber in the Langley 0.3-meter Transonic Cryogenic Tunnel (0.3-m TCT) in which high response instrumentation was used to measure the possible existence of these temperature fronts. Three different techniques were used to suddenly change the rate of liquid nitrogen being injected into the tunnel and the results from these three types of tests showed that temperature fronts do not appear to be present in the 0.3-m TCT. Also included are the velocity and pressure fluctuations measured in the settling chamber downstream of the screens and the associated power spectra.

Johnson, C. B.

Summary of test techniques used in the NASA Langley 0.3-meter Transonic Cryogenic Tunnel

This paper describes test techniques used to obtain data in the 0.3-m Transonic Cryogenic Tunnel. Main sections include steady aerodynamic testing, unsteady aerodynamics, non-intrusive measurements, tunnel performance, and fluid mechanics. Test techniques with adequate previous documentation are briefly presented and referenced, and those for which no documentation yet exists are more thoroughly discussed. Attention is given to the model building and instrumentation technology necessary for testing at high Reynolds numbers in the presence of free transition. It is concluded that the testing techniques thus far demonstrated in the 0.3-m TCT are on par with modern transonic tunnels, and that the specialized techniques needed to exploit the advantages of cryogenic operation can be realized.

Lawing, P. L.

Hot-Wire Probe for Compressible Subsonic Flow

Probe measures velocity, density, and total temperature fluctuations. Three-wire probe used with each wire operating at different overheat ratio. Technique extendable into transonic and low supersonic flow regimes without difficulty except for those problems usually associated with lengthy calibration and possible wire breaking.

Stainback, P. C.

Aerodynamic heating rate distributions induced by trailing edge controls on hypersonic aircraft configurations at Mach 8

Aerodynamic surface heating rate distributions in three dimensional shock wave boundary layer interaction flow regions are presented for a generic set of model configurations representative of the aft portion of hypersonic aircraft. Heat transfer data were obtained using the phase change coating technique (paint) and, at particular spanwise and streamwise stations for sample cases, by the thin wall transient temperature technique (thermocouples). Surface oil flow patterns are also shown. The good accuracy of the detailed heat transfer data, as attested in part by their repeatability, is attributable partially to the comparatively high temperature potential of the NASA-Langley Mach 8 Variable Density Tunnel. The data are well suited to help guide heating analyses of Mach 8 aircraft, and should be considered in formulating improvements to empiric analytic methods for calculating heat transfer rate coefficient distributions.

Kaufman, L. G., II

High Reynolds number tests of the cast 10-2/DOA2 transonic airfoil at ambient and cryogenic temperature conditions

The transonic airfoil CAST 10-2/DOA2 was investigated in several major transonic wind tunnels at Reynolds numbers ranging from Re=1 million six hundred thousand to forty five million at ambient and cryogenic temperature conditions. The main objective was to study the degree and extent of the effects of Reynolds on both the airfoil aerodynamic characteristics and the interference effects of various model-wind-tunnel systems. the initial analysis of the 10-2 airfoil results revealed appreciable real Reynolds number effects on this airfoil and, moreover, showed that wall interference, can be significantly affected by changes in Reynolds number thus appearing as true Reynolds number effects.

Stanewsky, E.

A study of dynamic measurements made in the settling chamber of the Langley 0.3-meter transonic cryogenic tunnel

Tests have been conducted in a cryogenic wind tunnel settling chamber using a fast response instrumentation to measure the possible existence of temperature fronts due to a sudden or step change in the rate of liquid nitrogen injection into the circuit. No indications of such fronts were obtained using three different techniques to change the rate of nitrogen injection. The normalized pressure and velocity fluctuations at two total temperatures and over a large range of Mach numbers and Reynolds numbers were about 2 x 10 to the -7th to 2 x 10 to the -6th and about 1.8 to 3 percent, respectively. There was no evidence of liquid nitrogen droplets in the flow down to a total temperature of 140 K. The pressure fluctuation power spectra from a pressure transducer correlated with the fan blade passage through the eighth harmonic of the fundamental frequency.

Johnson, C. B.

Investigation of sidewall boundary layer removal effects on two different chord airfoil models in the Langley 0.3-meter Transonic Cryogenic Tunnel

An investigation was carried out on two CAST 10-2 airfoil models with chords of 3 in. and 6 in. To evaluate the extent of sidewall influence on airfoil tests at transonic Mach numbers. The tests were conducted in the Langley 0.3-m Transonic Cryogenic Tunnel two-dimensional test section equipped with an upstream sidewall boundary layer removal system which reduces the boundary layer displacement thickness to about 1 percent of model halfspan from an initial 2 percent without boundary layer removal. Test results have shown the changes in the location of the shock on the upper surface of the airfoil to be about the same for both models with and without sidewall boundary layer removal. Even though large differences were noted in the high lift characteristics of the two models, the sidewall boundary layer removal had little effect on the differences. These tests also served to validate the boundary layer removal technique and the associated Mach number correction required with upstream boundary layer removal.

Murthy, A. V.