Engineering Papers⌕ Search

Engineering topics

Thermal systems

Find NASA NTRS and DOE OSTI research on heat transfer and thermal systems. Search heat pipes, cooling and thermal management in report titles and abstracts.

At least 1,153 records · Page 64

A Modified DBC Substrate Improving Thermal Performance for Confined Space Applications

High-power modules use substrates to house the semiconductor device and for electrical insulation. These substrates are constructed with thermally conductive dielectric material sandwiched between two metals to extract heat from semiconductor chips. Thus, the required cooling performance of a power module is linked to the substrate’s thermal performance and can vary based on the substrate technologies. Here, in this study, five substrate technologies were evaluated for space-restricted applications: direct-bonded copper (DBC), an insulated metal substrate (IMS), a thermally annealed pyrolytic graphite (TPG)-based IMS, DBC-based double-sided cooling, and direct-bonded aluminum (DBA) where the heat sink is directly attached without thermal interface materials (TIMs). The finite element (FE) analysis results suggest that the popular DBC substrate has thermal performance better than that of the other substrates for space-constrained applications. To further improve the thermal performance, a modified DBC substrate was proposed where a copper block was added between the semiconductor and the DBC substrate to achieve heat spreading underneath the chip. The modified DBC performance was then compared with the aforementioned substrates and the results showed significant thermal performance improvement. The results were verified with experimental results where the proposed substrate showed 20% more loss handling capability compared to an identical DBC substrate.

42 ENGINEERING↗

A behavior and physiology-based decision support tool to predict thermal comfort and stress in non-pregnant, mid-gestation, and late-gestation sows

Background: Although thermal indices have been proposed for swine, none to our knowledge differentiate by reproductive stage or predict thermal comfort using behavioral and physiological data. The study objective was to develop a behavior and physiology-based decision support tool to predict thermal comfort and stress in multiparous (3.28 ± 0.81) non-pregnant (n = 11), mid-gestation (n = 13), and late-gestation (n = 12) sows. Results: Regression analyses were performed using PROC MIXED in SAS 9.4 to determine the optimal environmental indicator [dry bulb temperature (T DB ) and dew point] of heat stress (HS) in non-pregnant, mid-gestation, and late-gestation sows with respiration rate (RR) and body temperature (T B ) successively used as the dependent variable in a cubic function. A linear relationship was observed for skin temperature (T S ) indicating that TDB rather than the sow HS response impacted TS and so TS was excluded from further analyses. Reproductive stage was significant for all analyses (P < 0.05). Heat stress thresholds for each reproductive stage were calculated using the inflections points of RR for mild HS and T B for moderate and severe HS. Mild HS inflection points differed for non-pregnant, mid-gestation, and late gestation sows and occurred at 25.5, 25.1, and 24.0 °C, respectively. Moderate HS inflection points differed for non-pregnant, mid-gestation, and late gestation sows and occurred at 28.1, 27.8, and 25.5 °C, respectively. Severe HS inflection points were similar for non-pregnant and mid-gestation sows (32.9 °C) but differed for late-gestation sows (30.8 °C). These data were integrated with previously collected behavioral thermal preference data to estimate the T DB that non-pregnant, mid-gestation, and late-gestation sows found to be cool (T DB < T DB preference range), comfortable (T DB = T DB preference range), and warm (T DB preference range < T DB < mild HS). Conclusions: The results of this study provide valuable information about thermal comfort and thermal stress thresholds in sows at three reproductive stages. The development of a behavior and physiology-based decision support tool to predict thermal comfort and stress in non-pregnant, mid-gestation, and late-gestation sows is expected to provide swine producers with a more accurate means of managing sow environments.

59 BASIC BIOLOGICAL SCIENCES↗

Snow thermal conductivity and conductive flux in the Central Arctic: Estimates from observations and implications for models

During the Arctic winter, the conductive heat flux through the sea ice and snow balances the radiative and turbulent heat fluxes at the surface. Snow on sea ice is a thermal insulator that reduces the magnitude of the conductive flux. The thermal conductivity of snow, that is, how readily energy is conducted, is known to vary significantly in time and space from observations, but most forecast and climate models use a constant value. This work begins with a demonstration of the importance of snow thermal conductivity in a regional coupled forecast model. Varying snow thermal conductivity impacts the magnitudes of all surface fluxes, not just conduction, and their responses to atmospheric forcing. Given the importance of snow thermal conductivity in models, we use observations from sea ice mass balance buoys installed during the Multidisciplinary drifting Observatory for the Study of Arctic Climate expedition to derive the profiles of thermal conductivity, density, and conductive flux. From 13 sites, median snow thermal conductivity ranges from 0.33 W m −1 K −1 to 0.47 W m −1 K −1 with a median from all data of 0.39 W m −1 K −1 from October to February. In terms of surface energy budget closure, estimated conductive fluxes are generally smaller than the net atmospheric flux by as much as 20 W m −2 , but the average residual during winter is −6 W m −2 , which is within the uncertainties. The spatial variability of conductive heat flux is highest during clear and cold time periods. Higher surface temperature, which often occurs during cloudy conditions, and thicker snowpacks reduce temporal and spatial variability. These relationships are compared between observations and the coupled forecast model, emphasizing both the importance and challenge of describing thermodynamic parameters of snow cover for modeling the Arctic as a coupled system.

54 ENVIRONMENTAL SCIENCES↗

Spacecraft Design Thermal Control Subsystem

This slide presentation reviews the functions of the thermal control subsystem engineers in the design of spacecraft. The goal of the thermal control subsystem that will be used in a spacecraft is to maintain the temperature of all spacecraft components, subsystems, and all the flight systems within specified limits for all flight modes from launch to the end of the mission. For most thermal control subsystems the mass, power and control and sensing systems must be kept below 10% of the total flight system resources. This means that the thermal control engineer is involved in all other flight systems designs. The two concepts of thermal control, passive and active are reviewed and the use of thermal modeling tools are explained. The testing of the thermal control is also reviewed.

thermal control↗

The Thermal Expansion of Ring Particles and the Secular Orbital Evolution of Rings Around Planets and Asteroids

The thermal expansion and contraction of ring particles orbiting a planet or asteroid can cause secular orbit evolution. This effect, called here the thermal expansion effect, depends on ring particles entering and exiting the shadow of the body they orbit. A particle cools off in the shadow and heats up again in the sunshine, suffering thermal contraction and expansion. The changing cross-section it presents to solar radiation pressure plus time lags due to thermal inertia lead to a net along-track force. The effect causes outward drift for rocky particles. For the equatorial orbits considered here, the thermal expansion effect is larger than Poynting-Robertson drag in the inner solar system for particles in the size range approx. 0.001 - 0.02 m. This leads to a net increase in the semimajor axis from the two opposing effects at rates ranging from approx. 0.1 R per million years for Mars to approx. 1 R per million years for Mercury, for distances approx. 2R from the body, where R is the body's radius. Asteroid 243 Ida has approx. 10 R per million years, while a hypothetical Near-Earth Asteroid (NEA) can have faster rates of approx. 0.5 R per thousand years, due chiefly to its small radius compared to the planets. The thermal expansion effect weakens greatly at Jupiter and is overwhelmed by Poynting-Robertson for icy particles orbiting Saturn. Meteoroids in eccentric orbits about the Sun also suffer the thermal expansion effect, but with only approx. 0.0003e2 AU change in semimajor axis over a million years for a 2 m meteoroid orbiting between Mercury and Earth.

Ring particles↗

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

International Conference on Envronmental Systems (ICES), Seattle WA NCTS 20964-15. The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earths magnetosphere as a laboratory tostudy the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10-4 Pa (10-6 torr)and the surrounding temperature achieving -180 C. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperatureversus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDAFLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 C of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 C and the heater power goal is to be within 5 of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Thermal↗

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10 (sup -4) pascals (10 (sup -6) torr) and the surrounding temperature achieving -180 degrees Centigrade. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperature versus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDA/FLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 degrees Centigrade of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 degrees Centigrade and the heater power goal is to be within 5 percent of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Correlation↗

Thermal Model Performance for the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in mid-2020, is currently undergoing a series of system-level environmental tests to verify its workmanship and end-to-end functionality. As part of this series, the Optical Telescope Element and Integrated Science Instrument Module (OTIS) Cryo-Vacuum (CV) test, the most complex cryogenic test executed to date by NASA, has recently been completed at the Johnson Space Center's Chamber A facility. The OTIS CV test was intended as a comprehensive test of the integrated instrument and telescope systems to fully understand its optical, structural, and thermal performance within its intended flight environment. Due to its complexity, extensive pre-test planning was required to ensure payload safety and compliance with all limits and constraints. A system-level pre-test thermal model was constructed which fully captured the behavior of the payload, ground support equipment, and surrounding test chamber. This thermal model simulated both the transient cooldown to and warmup from a 20 K flight-like environment, as well as predicted the payload performance at cryo-stable conditions. The current work is an assessment of thermal model pre-test prediction performance against actual payload response during the OTIS CV test. Overall, the thermal model performed exceedingly well at predicting schedule and payload response. Looking in depth, this work examines both the benefits and shortcomings of assumptions made pre-test to simplify model execution when compared against test data. It explores in detail the role of temperature-dependent emissivities during transition to cryogenic temperatures, as well as the impact that model geometry simplifications have on tracking of critical hardware limits and constraints. This work concludes with a list of recommendations to improve the accuracy of thermal modeling for future large cryogenic tests. The insight gained from the OTIS CV test thermal modeling will benefit planning and execution for upcoming cryogenic missions.

Testing↗

On-Orbit Spatial Performance Characterization for Thermal Infrared Imagers of Landsat 7, 8, and 9, ECOSTRESS and CTI

In this analysis of the spatial resolving power of thermal imagery products we focus on four satellite instruments that are used in research and applications, for example to monitor land surface temperature and derive evapotranspiration. These are thermal imagers on Landsat 7, Landsat 8, and Landsat 9, as well as the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). We compiled sets of close-in-time, day-time images of bridges surrounded by open water bodies, captured by each of the satellite imagers during cloud-free moments. Where possible, we also included some images captured by the Compact Thermal Imager (CTI), a technology demonstrator that was co-located with ECOSTRESS on the International Space Station in 2019. Bridges were found to provide a sufficient thermal contrast with the water surface to quantify the line-spread function of satellite-based thermal products. The full-width-at-half-max of a gaussian beam model fitted to this transect quantifies the on-orbit spatial resolution of different imagers. The results show some loss of spatial resolving power in the final product delivered to end-users as compared to the at-sensor characterization of spatial resolution. For Landsat 7, 8 and 9, the spatial resolution of the thermal bands is 1.5 times the ground sampling distance of 60 m and 100 m respectively. For the ECOSTRESS the difference is up to twice the sampling distance of 78 by 69 m2. Since spatial resolution is a main driver for instrument design it is important to understand and communicate this discrepancy between pre-flight design parameters and the characteristics of the surface imagery delivered to the user community. The goal of this research is to facilitate an improved fusion of current and future satellite observations into harmonized products with superior temporal and spatial characteristics.

thermal infrared↗

Exploration Extravehicular Mobility Unit (xEMU) Lunar Boot Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU lunar boots. Eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. This paper will address only the cold environment testing results. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through a heater cage surrounding the boots. Notably, the xEMU boots also contacted the liquid-nitrogen chilled floor inside of Chamber B, which provided a conduction pathway to simulate the thermal effects of the lunar surface. Test hardware was developed to extend the water tubing from the Liquid Cooling Ventilation Garment (LCVG) into the boots to set the internal thermal boundary nominally provided by the astronaut’s foot. Thirty-three temperature sensors were used to collect data in critical locations in the xEMU boot assembly as well as for calorimetry to determine heat flux to and from the boots. This paper will document the testing results and provide a high-level interpretation of the testing results. To conclude, this paper will address possible forward work and knowledge gaps present in lunar boot thermal performance and testing.

xEMU↗

Exploration Extravehicular Mobility Unit (xEMU) Hard Upper Torso (HUT) Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU hard upper torso (HUT). Two HUTs, one composite HUT and one aluminum HUT, were tested simultaneously in Chamber B, with different thermal environments. For the aluminum HUT on the Short xEMU (SxEMU) test article, five thermal profiles were tested during five simulated EVAs. For the composite HUT on the second xEMU, eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through two separate heater cages surrounding each respective test article. Seventy-two temperature sensors were used to collect data in critical locations in the xEMU HUT assembly. This paper will document the testing results and compare the test data against the xEMU HUT and system-level thermal models for model validation.

xEMU↗

Thermal-Fluid Analysis of a Liquid-Cooled Battery Module for Electrified Aircraft

The development of safe, energy-dense batteries is critical to advancing hybrid electric and fully electrified aircraft propulsion. Achieving this capability requires a thermal management system that can maintain battery performance and safety under demanding operational conditions. The objective of this project is to support the maturation of next-generation lithium-ion batteries for electrified aircraft by conducting performance testing on integrated battery modules, specifically a 2-cell series configuration module housed within an aluminum enclosure. Designed to operate at a nominal 7.2 V with discharge rates up to 2.5C, the module will eventually be used to power an electric motor and DC-DC converter, generating substantial thermal loads that must be effectively managed to increase the usable energy and power density of electrified aircraft. To address these thermal challenges, this study presents the development and thermal-fluid analysis of a liquid-cooled thermal management system. While the full aircraft architecture utilizes an eight-string configuration, the present work evaluates a representative single-string water coolant loop to characterize baseline performance. The active cooling loop circulates water through a reservoir, pump, the battery module, and a variable area flow meter. Key performance metrics including component-level temperatures, mass flow rates, and pressure drops are quantified across the loop. Across discharge rates ranging from 0.5C to 2.5C, the active thermal loop consistently and effectively removed heat from the module, validating the design approach and confirming readiness for further development. The validated thermal performance indicates a path toward scalable battery modules that could enable energy and power dense systems for hybrid electric aircraft.

Electrified Aircraft↗

Frontiers in Thermal Transport and Energy Conversion: Proceedings of a Workshop

Thermal transport and energy conversion has remained an active field for at least 200 years, with numerous opportunities for discoveries and new applications. Recently, experiments have advanced researchers’ understanding of basic physics, and how new discoveries might translate into applications in energy, materials, quantum technologies, and other areas. The National Academies convened a workshop on April 11, 2019 to identify and assess the frontier of current research in the field of thermal transport and energy conversion. Discussions involved topics related to thermal transport and quasi-particle hydrodynamics, thermal transport beyond the quasiparticle paradigm, the thermal hall effect from neutral spin excitations in frustrated quantum magnets, quantization of the thermal hall conductivity at small hall angles, and thermal spin transport, including spin-Seebeck and magnon drag effects. These topics were strategically selected with the goal of uncovering key challenges, opportunities, and issues in order to guide future efforts and investments to advance the field. This publication offers a condensed summary of the discussions and presentations from the workshop, which was unclassified and open to the public.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Milestone 1.2.16. Reconciling the Impacts of Thermal Pretreatment on Radiation-Induced H2 Generation from Aluminum-Clad Spent Nuclear Fuel Surrogate Materials

To support the technical basis for the extended dry storage of aluminum-clad spent nuclear fuel (ASNF), thermal pretreatment procedures to minimize the radiation-induced generation of molecular hydrogen (H2) have been investigated. The aim of thermal pretreatment is to eliminate the residual adsorbed water content on the ASNF’s corrosion layers, precursors for H2 generation. To date, irradiation studies in this area have found conflicting results for the effectiveness of thermal pretreatment procedures. The aim of this study was to reconcile those differences. However, the presented results, which utilized a modified in situ thermal pretreatment procedure, afforded H2 yield data that further indicates that thermal pretreatment does not significantly reduce the radiation-induced yield of H2 from gamma irradiated ASNF surrogate materials. Assessment of the differences between thermal pretreatment studies suggests that stainless-steel—present in the irradiation setup of studies that demonstrated a reduction in the yield of H2 with thermal pretreatment—may afford not only unanticipated interfacial chemistry, but also the formation and radiolytic contribution of iron oxides to the chemistry underpinning the formation of H2 in these systems. Given the Department of Energy Standard Canister—proposed for the extended dry storage of ASNF—is predominantly composed of stainless-steel, the potential contribution of stainless-steel and its corrosion layers to radiolytic H2 production should be further investigated. This research was funded by the U.S. Department of Environmental Management, Office of Technology Development, under contract DE-AC07-05ID14517.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Experimental investigation of thermal conductivity of high entropy ceramics

In this talk, we will present the experimental investigation of thermal conductivity of high entropy carbides (HEC) and borides (HEB) with different compositions. Thermal conductivity determines the capability of a material to transport thermal energy and is considered as one critical physical property, specially in the energy industry. Due to the presences of disordered cation sublattice, it is expected that thermal conductivity of high entropy ceramics is lower than the counterparts with simpler compositions, but the experimental studies are relatively few. Using laser-based spatial-domain and frequency-domain thermoreflectance technique, we measured thermal conductivity of HECs and HEBs in a temperature range from 77K to 773K. Furthermore, by focusing the laser using an objective lens, we were able to perform the thermal property mapping on samples with the spatial resolution of micrometer. Such measurements could reveal important microstructure information in a rapid and efficient way without using scanning electron microscopy. The high spatial resolution also enables thermal conductivity measurements on ion-irradiated HECs with the damage layer of merely 1.1µm. These measurements can provide valuable information to predict the performances of HECs and HEBs with different compositions and from different manufacturing processes, and in the extreme environments such as nuclear reactors.

36 - MATERIALS SCIENCE↗

Local Thermal Conductivity Patterning in Rotating Lattice Crystals of Anisotropic Sb 2 S 3

The ability to control material heat transport properties over space and time can drive advanced functionalities in thermal management for electronics and system-on-chip, and enable thermal circuits. Despite the technological relevance, there are limited demonstrations of local thermal property control. Rotating lattice single (RLS) crystals—formed via laser-induced crystallization of an amorphous substrate—offer a novel avenue for local crystal engineering, unlocking opportunities for microscale property patterning. Here, thermal conductivity (𝜅) imaging is applied to RLS crystals of Sb2S3 to resolve microscale 𝜅 variations across patterned regions. Amorphous areas exhibit 𝜅 as low as 0.6 Wm −1 K −1 , while crystalline regions display periodic 𝜅 variations from 0.7 to over 2.5 Wm −1 K −1 . These variations correspond to changes in crystal orientation, revealing marked 𝜅 anisotropy. The crystal out-of-plane direction (c axis)—featuring van der Waals bonds—shows amorphous-like transport, whereas in-plane directions (a, b axes) exhibit 3.5x and 1.7x larger 𝜅, respectively. First-principles calculations, in excellent agreement with experiments, suggest that the in-plane anisotropy originates from expressed Sb lone pairs, which impart a corrugation along the b axis affecting bond stiffness and 𝜅. These findings demonstrate microscale control of thermal properties via laser-processed metastructures, with significant implications for next-generation thermal management.

14 SOLAR ENERGY↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Demonstration and characterization of insertable passive thermal switches for dynamic building envelopes

A dynamic building envelope integrated with thermal energy storage, such as phase change material (PCM), is an emerging technology that offers a promising solution to improve the energy efficiency of buildings. This study reports the development of insertable thermal switches, which modulate thermal resistance, thereby making building envelopes dynamic and enhancing the use of free ambient heating and cooling. The reported thermal switches are passive, meaning they work solely based on indoor and outdoor temperatures. A single switch when inserted into 10 × 10-in (0.064-m 2 ) XPS foam board insulation demonstrates effective thermal conductivity of 0.050 W/m-K in the resistive state and 0.285 W/m-K in the conductive state. Thermal switches exhibit an effective switching ratio of 5.7, with no noticeable degradation in performance over 770 cycles. Additionally, when integrated into a wall sample containing a PCM layer, switches significantly reduce the PCM solidification time by 43.2% during the cooling process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗