Engineering Papers⌕ Search

Engineering topics

Xiaoxiong Xiong

Publications and source records attributed to Xiaoxiong Xiong.

At least 73 records · Page 4

Improvements in the Calibration of the NOAA-20 VIIRS Day-Night Band Low Gain Stage Using a Solar Diffuser

We aim to introduce and demonstrate several improvements that are applied to the on-orbit solar diffuser (SD) calibration of the day-night band (DNB) low gain stage (LGS) of the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the NOAA-20 satellite. The most important improvement is the expansion of the angular range, referred to “sweet spot”, from 4° to 7.8° in order to increase the number of fully-illuminated scans considered for the SD calculation. The increase in scan number enables the completion of on-orbit calibration using the SD within one orbit, compared with the multiple orbits approach, which is required in the current standard approach applied in operational DNB LGS calibration coefficients look-up tables (LUTs) updates. The NOAA-20 DNB LGS calibration coefficients have been derived with the new methodology and the results show a more stable, smoother, and less noisy trend when compared with the current standard approach. The results also demonstrate that the NOAA-20 VIIRS DNB overall on-orbit performance has been very stable.

NOAA-20↗

MODIS Reflective Solar Bands Lunar Calibration Update and Improvements

The MODerate resolution Imaging Spectroradiometer (MODIS) instruments on-board the Terra and Aqua spacecrafts were launched on December 18, 1999 and May 4, 2002, respectively. Each instrument has been scheduled to view the Moon through its Space View (SV) port approximately once per month in order to monitor the long-term radiometric stability of their reflective solar bands (RSB). The lunar calibration has played a key role in tracking the change in the response versus scan angle (RVS) of the instrument’s scan mirror, which is an essential part of the RSB calibration. The lunar irradiance observed by MODIS depends on the view geometry and it is crucial to remove the geometric effects in order to derive accurate RSB calibration coefficients. With a scheduled roll maneuver, the lunar phase angles are kept in a narrow range of 1° for each MODIS instrument such that the impact of these geometric effects is minimized. Nevertheless, it remains a challenge to completely remove the impact of geometric effects in the calibration coefficients derived from the lunar observations, considering the high expectations for the accuracy and quality of the results. In the current MODIS lunar calibration, the geometric effects on the lunar irradiance are corrected by the RObotic Lunar Observatory (ROLO) model. The overall relative uncertainty of the ROLO model for the MODIS calibration has been assessed to be about 1% in the selected lunar phase angle range of 1°. It could be as large as 4% beyond this small phase angle range, especially for the shortest wavelengths. This uncertainty induces noticeable oscillations in the calibration coefficients derived from the lunar observations. We developed a simple lunar model, which is based on MODIS lunar measurements, derived from scheduled lunar observations, as well as those obtained from intrusion of the Moon in the SV, referred to as unscheduled lunar observations, in the time period from 2005 to 2012. Here, the scheduled lunar observations for the entire mission are reprocessed with the new lunar model applied to correct the view geometry effects for each MODIS instrument. New calibration coefficients for the RSBs are calculated. We show that oscillations and noise in the derived lunar calibration coefficients are significantly reduced for both MODIS instruments.

Terra↗

Performance Assessments of the SNPP and N20 VIIRS DNB Using Observations of Bright Stars

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the Suomi-NPP (SNPP) and NOAA-20 (N20) spacecrafts is a multi-spectral Earth-observing instrument with spectral channels ranging from the visible to the long-wave infrared. In addition to these spectral channels, the VIIRS instrument features a panchromatic Day/Night band (DNB) with 3 gain stages (low, mid, and high) which allows for Earth-view (EV) radiance retrievals over 7 orders of magnitude. The DNB is able to collect data ranging from dim city lights during nighttime up to reflected sunlight from cloud-tops during daytime. The DNB data collection is divided into 32 aggregation modes, where sub-pixel aggregation is used to maintain a nearly constant pixel footprint on ground during EV data collection throughout each scan. The DNB is also sensitive enough to observe bright stars through the instrument space-view (SV) port. Data from these bright stars can be used to track the temporal stability of the sensor gain and as a method of intercomparison between the two VIIRS instruments. In this work, we will present several sensor performance assessments of the VIIRS DNB using stars. In addition to the sensor gain trending, these assessments will include a comparison of the differences between the daytime and nighttime data due to the effects of stray-light, a comparison of the measured signal as a function of aggregation mode, a comparison between the two high-gain sub-stages, and half-angle mirror side for both the SNPP and N20 VIIRS DNB.

VIIRS↗

Analysis of the on-orbit Response-Versus-Scan-angle for the MODIS SWIR Bands Derived from Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Terra and Aqua platforms is a multi-spectral, whiskbroom scanning radiometer with 36 spectral bands covering wavelengths from 0:4 - 14:2 μm. Among these bands, the 20 reflective solar bands (RSB, 0:4 - 2:1 μm) use an on-board solar difuser (SD) and SD stability monitor (SDSM) to track the detector gain changes on orbit. In addition to this, lunar and Earth-view (EV) observations are used in order to characterize the scan-mirror response versus scan angle (RVS), which improves the Earth-view retrieval over the full width of each scan. For the short-wave infrared bands (SWIR, 1:2 - 2:1 μm), the prelaunch RVS has been used for both Aqua and Terra MODIS throughout each mission. While these bands are not expected to have a significant change in the RVS on-orbit, issues such as electronic crosstalk and an out-of-band optical leak have prevented the use of the Moon for deriving the on-orbit RVS for validation. However, recent improvements to the MODIS lunar calibration for the SWIR bands allow us to mitigate the electronic crosstalk impact and derive the RVS for the SWIR bands. In this work, we will assess the impact of this newly derived RVS on the EV data compared to MODIS Collection 6.1. By comparing to EV data obtained from pseudo-invariant calibration sites at different angles-of-incidence on the scan mirror, we can assess the effectiveness of the newly derived RVS from the Moon. We find that while the change in the RVS on-orbit for the SWIR bands is relatively small, applying a correction to the RVS based on the Moon and SD data can provide an improvement for some bands.

MODIS↗

Monitoring VIIRS Thermal Emissive Bands Long-Term Performance Using Lunar Observations

Two Visible Infrared Imaging Radiometer Suite (VIIRS) instruments are currently operating in space, one onboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite launched on October 28, 2011 and the other onboard the NOAA-20 satellite launched on November 18, 2017. The performance of the seven VIIRS thermal emissive bands (TEBs) is monitored via on-orbit calibration data, the analysis of Earth view observations, as well as inter-comparisons with other sensors. The Moon has been used as a unique invariant target for on-orbit sensor calibration because its surface property is considered extremely stable over time in spectra, radiometry, and geometry with a repeatable lunar phase. This paper presents the assessments of the S-NPP and NOAA-20 VIIRS TEB on-orbit calibration stability using near-monthly scheduled lunar observations over their respective missions. The methodology previously developed for MODIS is now applied to VIIRS to monitor the TEB long-term stability by extracting and trending the lunar brightness temperatures from selected unsaturated pixels. It includes a correction applied to reduce any impact from the Sun–Moon geometry (e.g. Sun-Moon distance variation). The results show that the mission-long brightness temperature trends from the lunar surface are stable for all VIIRS TEBs, despite noticeable seasonal variations in the lunar thermal emissive radiance.

VIIRS↗

NOAA-20 Visible Infrared Imaging Radiometer Suite day–night band on-orbit calibration and performance

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been successfully operating on orbit since November 28, 2017. The day–night band (DNB) onboard NOAA-20 VIIRS is a panchromatic channel covering wavelengths from 0.5 to 0.9 μm, capable of observing the Earth scene in visible/near-infrared spectral range at a spatial resolution of 750 m. The DNB operates at low-, mid-, or high-radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low-gain stage calibration. The SD observations also provide a means to compute gain ratios between low-to-mid and mid-to-high-gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. We provide an assessment of the DNB on-orbit performance and behavior in the first two-year mission period and beyond. The calibration methodology used by the VIIRS Characterization Support Team in support of the NASA Earth science community has been described. The trending of on-board calibrators dark-offsets, SD gains, and gain ratios, and signal-to-noise ratio at minimum radiance have been analyzed, especially during key events such as the nadir and cryocooler doors opening. Furthermore, we performed intercomparison studies between Suomi National Polar-orbiting Partnership and NOAA-20 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains, gain ratios, and straylight correction, as well as the calibration comparison between the NOAA Interface Data Processing Segment look-up-tables and our delivery results.

VIIRS↗

Twenty Years of Terra MODIS Spectral Performance using the Spectro-Radiometric Calibration Assembly

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on-board the Terra spacecraft has provided valuable Earth data to the science community for the last 20 years. Equipped with several on-board calibrators (OBCs), MODIS has continued to operate nominally since its launch in December 1999. The Spectro-Radiometric Calibration Assembly (SRCA) is one such OBC that is able to provide on-orbit measurements of the MODIS reflective solar bands (RSBs) in radiometric, spatial and spectral modes. While the SRCA is operating in spectral mode, it is able to monitor the center wavelength (CW), bandwidth (BW) and in-band relative spectral response (RSR) of most RSBs. Prelaunch measurements of the CWs, BWs and RSRs of the RSBs were performed at the system level using the Spectral measurement Assembly (SpMA). Using both the prelaunch measurements and the measurements obtained on-orbit using the SRCA, the changes in the spectral response of the MODIS reflective bands can be monitored throughout the mission. This paper will provide a brief description of the spectral calibration approach and report on-orbit changes in these spectral performance parameters and their uncertainties over the last 20 years. It will also address changes to the SRCA operation on-orbit and their impact on measured spectral calibration results. Despite two decades in orbit, the spectral responses for most Terra MODIS reflective bands continue to remain within their design specifications.

MODIS↗

MODIS TEB Calibration Algorithm Improvements for Future L1B Collection

Terra and Aqua MODIS have provided continuous global observations for scientific applications for more than 20 and 18 years, respectively. The radiometric calibration of the MODIS thermal emissive bands (TEB) is based on a quadratic approximation of the instrument response. The calibration coefficients look-up tables (LUTs) are updated using the response of the MODIS on-board blackbody (BB)with the response background subtracted by space view. The quarterly on-board BB warm-up and cool-down activity temperature ranges from 270 K to 315 K, and the derived offset has a relatively large uncertainty. Electronic cross-talk, an artifact that affects both instrument calibration and Earth view (EV) radiance retrievals, is corrected based on lunar observations. Calibration assessments using EV observations (e.g. ocean, desert, Antarctic Dome Concordia, and deep convective clouds) provide useful information to evaluate the impact of the Terra safe mode (February 2016) and Aqua MODIS formatter reset (January 2018) events on both MODIS instruments. This study focuses on the TEB radiometric calibration algorithm improvements for future collections based on calibration assessments using EV measurements and analytical modeling. Measurement stability and consistency over specific Earth scenes with a wide temperature range, as well as their brightness temperature (BT) dependency, are used for bias estimations in the calibration coefficients. Calibration coefficients are derived and updated after adjusting the current fitting algorithm. Thereafter, using the test LUTs, their impact on the Level 1B (L1B) data for different EV scenes is analyzed.

MODIS↗

S-NPP and N20 VIIRS RSB Bands Detector-to-Detector Calibration Differences Assessment Using a Homogeneous Ground Target

The S-NPP and N20 satellites have successfully operated since their launches on October 28, 2011 and November 18, 2017, respectively. This paper provides an assessment of the detector calibration stability for the reflective solar bands (RSBs) observed from both S-NPP and N20 VIIRS. Top-of-atmosphere radiances from near-nadir observations over the homogeneous Libya 4 desert site are extracted from the S-NPP VIIRS Collection 1 and N20 Collection 2 Level-1B products. The radiances from individual detectors per Half‐angle Mirror side are studied. The comparisons of the normalized radiance to all detector average values indicate that the detector calibration differences are wavelength dependent. The S-NPP detector differences have been slowly increasing in the past 8.5 years and bands M1-M4 have 1.3%- 2.2% detector differences in 2019. N20 detector differences are stable and small in the past two years except SWIR M bands. N20 M10 and M11 have 1.3% and 2.1% detector differences, respectively. S-NPP DNB detector differences are about 0.8% and N20 DNB detector differences are about 0.5%. Most bands HAM side differences are less than 0.25% in the past years except N20 VIIRS M1 HAM side differences are 0.57% in 2018 and 0.54% in 2019. The Libya 4 images have small but noticeable striping in S-NPP M1-M4 data as well as in N20 M1, M8, M10, and M11 data. These study results have been applied in the S-NPP Collection 2 new algorithm to remove the detector differences. This research help scientists and VIIRS users better understand detector calibration differences in different version VIIRS products.

Libya 4↗

N20 VIIRS RSB Calibration Algorithms and Results: Collection 2.0

The NOAA-20 (N20) satellite, previously the Joint Polar Satellite System-1 satellite, was launched on November 18, 2017. One of the five major scientific instruments aboard the satellite is the Visible Infrared Imaging Radiometer Suite (VIIRS). VIIRS scans the Earth’s surface in 22 spectral bands, 14 of which are the reflective solar bands (RSBs) with band center wavelengths from 0.412 to 2.25μm. VIIRS regularly performs on-orbit radiometric calibration of its RSBs, primarily through the observations of the onboard solar diffuser (SD). The on-orbit change of the SD’s bidirectional reflectance distribution function, known as the H-factor, is determined by the onboard SD stability monitor (SDSM). Since the H-factor exhibits angular dependence, obtaining the H-factor along the SD to the telescope direction is a challenge for the NOAA-20 VIIRS. Recently, Collection 2.0 of the NASA Land Science Investigator-led Processing Systems (SIPS) products were released. As a part of this reprocessing effort, we made two major improvements in the N20 VIIRS RSB radiometric calibration. One is the improved SD and SDSM attenuation screen transmittance functions, obtained by using calibration data collected during both the yaw maneuver and a small portion of regular orbits, resulting in a higher quality H-factor for the SDSM view. Another is the use of the H-factor for the telescope view, derived from the H-factor for the SDSM view, by using the results for the SNPP VIIRS. In June 2019, we delivered a set of mission-long N20 VIIRS Collection 2.0 RSB radiometric calibration look-up-tables. These tables have been employed by the NASA Land SIPS group to reprocess the entire time series of the NOAA-20 VIIRS products. In this paper, we discuss the Collection 2.0 NOAA-20 VIIRS RSB calibration algorithms and results.

N20 VIIRS↗

The MODIS TEBs Calibration and Look-up Table Delivery Process for Collections 6 and 6.1

MODIS is a cross-track, whisk-broom scanning imaging radiometer with a double-sided scan mirror that collects data in 36 spectral bands. Sixteen of the 36 MODIS spectral bands are Thermal Emissive Bands (TEBs) whose spectral wavelengths range from 3.5 μm to 14.4 μm. The TEB detectors are calibrated on a scan-by-scan basis using a quadratic calibration algorithm by observing both the MODIS on-board blackbody (BB) and a background space view reference. Blackbody warm-up/cool-down (WUCD) events are performed quarterly to track on-orbit changes associated with the TEB detectors' non-linearity. Following each WUCD, the calibration coefficients in the quadratic algorithm, and their associated contributions to the total uncertainty, are updated and delivered through separate look-up tables (LUTs) when all update criteria are met. Afterwards, the LUTs are incorporated into the Level 1B (L1B) product. Since the Terra MODIS mission began, a steady increase in electronic cross-talk has been observed for TEBs 27{30. Starting from Collection 6.1, an algorithm has been applied using correction coefficients derived from regularly-scheduled lunar observations, with the correction LUT update dependent on its impact on the current L1B product. The MODIS Characterization Support Team (MCST) has established a comprehensive set of procedures to assure timely and accurate LUT updates, and maintain the quality and accuracy of the L1B and science products. This paper provides an overview of the current calibration and LUT delivery process for the MODIS TEBs in Collections 6 and 6.1.

MODIS↗

Long Term Stability Monitoring of Aqua MODIS Thermal Emissive Bands through Radiative Transfer Modeling

Moderate Resolution Imaging Spectroradiometer (MODIS) on Aqua has been in operation providing continuous global observations for science research and applications since 2002. The long-term stability of thermal emissive bands (TEBs) of Aqua MODIS was monitored through inter-comparisons with measurements by hyperspectral infrared sensors, such as AIRS on Aqua and IASI on MetOp satellite, or through long term vicarious monitoring over cold targets, such as Dome- C and deep convective clouds (DCC). In this paper, a radiative transfer modeling-based simulation model using Community Radiative Transfer Model (CRTM) is developed to perform the long-term monitoring of the stability of TEBs of Aqua MODIS. CRTM is a fast-radiative transfer model for calculations of radiances for satellite infrared radiometers and is able to output infrared radiance and brightness temperature at spectral bands of MODIS. Long term European Centre for Medium-Range Weather Forecasts (ECMWF) global atmospheric reanalysis data, such as temperature and humidity profiles, are used as inputs to the CRTM simulation. By confining the area of interest to be over low to middle latitude ocean, the long-term stabilities of selected Aqua MODIS TEBs are monitored through Observation–Background (O-B) brightness temperature (BT) bias between MODIS measurements and BT retrieval from CRTM simulation. The consistency and relative stability between Aqua MODIS and ECMWF reanalysis data for surface channels of MODIS are evaluated. In addition, the radiative transfer modeling with CRTM enables us to evaluate the impacts of long term variation of global CO2 distribution on the O-B BT biases for CO2 channels of Aqua MODIS through comparison of simulations with constant or long term variable CO2 as inputs. The O-B analysis with RTM show that Aqua MODIS surface channels are all radiometrically stable with yearly BT bias drift less than 0.004K/year for B20, B22, B23 and ~0.01K/year for B31 and B32. The CO2 absorption channels of Aqua MODIS, e.g. B33-B36, are stable with BT bias drift < 0.005K/year.

MODIS↗

The Effect of UV and Solar Wind Exposure on the Reflectance of Two Black Diffuse Materials

The Bidirectional Reflectance Distribution Function (BRDF) and Total Hemispherical Reflectance (THR) of two candidate black diffuse materials for the dim calibration targets of the NASA GSFC PACE Ocean Color Instrument (OCI)were reported in the SPIE conference last year. In this paper, we present new BRDF and THR results of the two black diffuse materials following additional UV exposure and solar wind tests. The BRDF measurements for five samples of each two black diffuse material were made at incident angles of 0° and 45° and at the wavelengths of 360 nm, 600 nm, and 1600 usi ng the Table-top Goniometer (TTG) located in the Diffuser Calibration Laboratory (DCL) at NASA GSFC. The THR of the samples, 15 mm in diameter, was measured using a commercial UV-VIS-NIR spectrophotometer from 200 nm to 2500 nm. The spectral THR results of the two black diffuse materials exposed to UV and solar wind show an approximate 10 % higher reflectivity than the unexposed samples. The spectral profiles of the THR of the exposed and unexposed samples are relatively similar. The BRDF results at the incident angle of 45° show different trends in the forward and backward scattering regions, while those at normal incident angle are consistent with the THR results. We will also present the details of the samples’ surface features and the comparison of the 0°/45° BRDF and THR results, demonstrate the significance of background subtraction in the THR measurements for small, low reflectance samples, and discuss validation of BRDF scale, measurement repeatability, and major contributions of uncertainty.

Jinan Zeng↗

Terra MODIS: 20 years of on-orbit calibration and performance

Since its launch in December 1999, Terra Moderate Resolution Imaging Spectroradiometer (MODIS) has successfully operated for more than 20 years, with its observations generating a broad range of science data products that have greatly enabled the remote sensing community and users worldwide in their studies of many key geophysical parameters of the Earth’s systems. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.4 μm, which are calibrated by a set of onboard calibrators (OBCs). Also contributing to the sensor’s mission-long on-orbit calibration and characterization are near-monthly scheduled lunar observations and multiple time series of the sensor’s responses over select ground targets at a variety of scan angles. To a large extent, the quality of MODIS data products relies strongly on the dedicated efforts to operate and calibrate the instrument, to derive and update calibration parameters, and to develop and implement new calibration strategies and algorithms in response to on-orbit changes of the sensor’s characteristics and its OBC functions. We provide an overview of the Terra MODIS on-orbit operation and calibration activities over the last 20 years, including changes made to extend and preserve the instrument and OBC functions and their operation strategies. It also illustrates the sensor’s on-orbit performance with results derived from its OBC, lunar observations, and select ground targets and discusses major changes in sensor characteristics and corrections applied to the L1B algorithms as well as calibration lookup table updates. To date, the Terra MODIS instrument and its OBCs continue to operate and function normally. Except for those identified prelaunch, most spectral bands and detectors continue to meet their specified calibration requirements. Also discussed in our paper are lessons learned from Terra MODIS operation and calibration, as well as future efforts to further extend and maintain the quality of its long-term data records.

Terra↗

SNPP VIIRS Reflective Solar Bands On-Orbit Calibration Using the Moon

The Visible Infrared Imaging Radiometer Suite (VIIRS) on board the Suomi National Polar-Orbiting Partnership (SNPP) satellite has been on orbit for more than eight years since its launch on October 28, 2011. The VIIRS has 22 spectral bands, among which 14 are reflective solar bands(RSBs) covering a spectral range from 0.41 to 2.25 m. The VIIRS RSBs are primarily calibrated on-orbit by an onboard solar diffuser (SD) panel and a solar diffuser stability monitor (SDSM). Besides the SD and SDSM calibration, the RSBs are scheduled to view the Moon approximately monthly through the instrument’s space view (SV). The lunar observations have also been used to calibrate the RSBs on-orbit since early mission. Due to the non uniformity of the SD’s degradation, the calibration coefficients that are derived from the SD/SDSM calibration have long-term biases, especially at short wavelengths. In addition, the SDSM has no capability to monitor the SD degradation beyond 0.935 m, resulting in long-term bias in the shortwave infrared bands, about 0.72% for band M8 (1.238 m). These biases induce significant errors and long-term drifts in the VIIRS sensor data records (SDR) and consequently in the environmental data records (EDR). Unlike the SD, the Moon is a known stable target and any temporal drifts observed while viewing the Moon can be attributed to the sensor’s degradation. Thus, the VIIRS lunar calibration is used to track the RSB on-orbit changes, especially to provide an accurate long-term baseline. Due to the non-uniformity of the lunar surface, the lunar irradiance, instead of the lunar radiance, is used to calibrate the RSBs. The lunar irradiance strongly depends on lunar view geometry and it is still a challenge to accurately characterize the geometric effects associated with the lunar measurements and any residual errors can induce seasonal oscillations in the derived calibration coefficients. The errors of the geometric dependence correction induce seasonal oscillations in the derived RSB lunar calibration coefficients. In this paper, the algorithms for the view geometric effect correction are significantly improved, resulting in a significant reduction in the seasonal oscillations observed in the calibration coefficient time-series. The lunar and SD/SDSM calibration results are properly incorporated to generate a set of hybrid calibration coefficients and implementation of these coefficients is shown to significantly improve the long-term stability of the VIIRS SDR. This is of fundamental importance in making accurate Earth observations from which reliable and high quality science products are generated. The consequent improvements in SNPP VIIRS RSB SDRs and EDRs are shown and discussed. The lunar calibration methodology can be directly applied to follow-on VIIRS instruments.

Junqiang Sun↗

Improved Lunar Irradiance Model Using Multiyear MODIS Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on board the Terra and Aqua spacecrafts were launched on December 18, 1999, and May 4, 2002, respectively. One of the features of the MODIS instruments is the ability to perform observations of the lunar surface from its space view (SV) port. This event is scheduled approximately once a month via a spacecraft roll maneuver, which enables the lunar phase to be confined to within 1° for each instrument. The Moon is considered to be an extremely stable reference to monitor the long-term radiometric stability of the reflective solar bands (RSB). Each MODIS instrument can also view the Moon for about four months in a year without a roll maneuver. This is caused by the intrusion of the Moon in the SV. The lunar phase angles of these unscheduled lunar observations are distributed over a wide range varying from approximately 50° to 80° for Terra MODIS and from about -80° to -50° for Aqua MODIS, where the positive phase angle refers to a waning Moon, while the negative phase angle corresponds to a waxing Moon. Together, the scheduled and unscheduled lunar observations are used to monitor the long-term radiometric stability of the RSB. Of the several challenges involved in the modeling of the lunar optical properties, such as its absolute brightness, a number of optical and view geometry effects need to be considered. These effects are much easier to characterize for the scheduled observations due to confinement of the lunar phase angles compared to those for the unscheduled intrusions of the Moon in the SV. Nevertheless, it is still a challenge to remove the view geometry effect in the calibration coefficients derived from the scheduled lunar observations and even more challenging for the unscheduled lunar intrusions. In this work, the lunar absolute irradiance is modeled using known attributes and from the lunar observations by the two MODIS instruments from the time period between the years 2005 and 2012.

Calibration↗

MODIS and VIIRS Calibration History and Future Outlook

The MODIS is a key instrument for NASA’s EOS program, currently operated onboard the Terra and Aqua spacecraft launched in 1999 and 2002, respectively. The VIIRS is a MODIS follow-on instrument for the JPSS program. Adding to the ones operated onboard the S-NPP and NOAA-20 satellites launched in 2011 and 2017, respectively, three nearly identical VIIRS instruments will also be launched. This will enable the data records from MODIS and VIIRS to be extended beyond 2040. In addition to various applications and scientific studies of the Earth’s system, long-term data records from MODIS and VIIRS observations will greatly benefit the space-based climate observing system. This is attributed to the high-quality measurements and extensive calibration efforts, from pre-launch to post-launch. This paper provides an overview of MODIS and VIIRS calibration history and approaches applied to establish and maintain sensor calibration traceability and accuracy. It illustrates calibration and performance issues through different phases of the mission using examples derived from ground testing equipment, on-board calibrators, and other calibration targets. Moreover, discussed in this paper are outstanding challenges and future efforts to maintain and improve sensor calibration stability and long-term data quality, and to better support the space-based climate observing system.

MODIS↗

Effects of Out-of-Band and Time-Varying Relative Spectral Response on the Calibration of MODIS Reflective Solar Bands

Calibration of the on-orbit gain changes of the narrow bandwidth reflective solar bands (RSB) of Terra and Aqua MODIS is usually based on the band center wavelength. The relative spectral response (RSR) of each band is assumed to be constant on orbit and the time dependence of an overall gain factor is calculated. Any on-orbit changes to the RSR of the MODIS bands will introduce some error into the calibration and may also have an impact on the Earth scene radiance retrieval. We consider two different ways to track how the RSR of the MODIS RSB may be changing on orbit, and the effects that these changes will have on the calibration. First, we study the broadband degradation of the MODIS scan mirror and how it may be changing the effective out-of-band response of the RSB. Second, we examine in-band RSR measurements from the spectro-radiometric calibration assembly (SRCA) carried on-board both MODIS instruments. We find that RSR changes have a relatively small effect on the radiance calibrated using the on-board solar diffuser, generally less than 0.5% for all RSB at any time in the missions, though the effect may be slightly larger for some scan angles. The impact of RSR changes on the Earth scene radiance retrieval is highly dependent on the spectral properties of the scene and could be significantly larger. The bands showing the largest impacts are Terra bands 1, 4, 8, 9, 17, and 19 and Aqua bands 8 and 9.

MODIS↗