S-NPP VIIRS Solar Diffuser Degradation at the View Direction of the Rotating Telescope Assembly

S-NPP VIIRS has been on-orbit for more than nine years since it was launched on October28th,2011. The VIIRS reflective solar bands (RSBs) are calibrated on-orbit primarily by an onboard solar diffuser (SD). The SD on-orbit degradation is tracked by an onboard SD stability monitor(SDSM). The VIIRS RSBs view the SD through a rotating telescope assembly (RTA). The RTA views the SD from a direction that is quite different from that of the SDSM. It has been shown that the SD degrades non-uniformly with respect to the incident and outgoing directions, especially at the short wavelengths. Thus, the SDSM calibration cannot provide an accurate SD degradation estimation for the view direction of the RTA, resulting in long-term drifts in the calibration coefficients derived from the SD and SDSM calibration. S-NPP VIIRS has been scheduled to view the Moon approximately monthly since its launch. The lunar observations can provide accurate long-term trends for the RSB calibration coefficients since the lunar surface reflectance is quite stable. By comparing the SD and lunar calibration results, we can obtain the SD degradation differences at the view directions of the SDSM and RTA and derive the SD degradation at the view direction of the RTA. Moreover, we can also derive the SD degradation in the short-wave infrared (SWIR) spectral range, wherein the SDSM cannot track the SD degradation. In this paper, we will derive the SD degradation for the view direction of the RTA from the SD, SDSM, and lunar calibrations from the visible to SWIR spectral range. We will also simulate the SD degradation with analytical models and compare their performances.

SNPP VIIRS↗

Evaluation of Aqua MODIS Thermal Emissive Bands Stability through Radiative Transfer Modeling

Moderate Resolution Imaging Spectroradiometer (MODIS) on Aqua has been inoperation providing continuous global observations for science research and applications since2002. The long-term stability of thermal emissive bands (TEBs) of Aqua MODIS was monitoredthrough inter-comparisons with measurements by hyperspectral or multi-spectral infraredsensors or through vicarious monitoring over cold targets such as Dome-C and deep convectiveclouds. The radiative transfer modeling (RTM)-based simulation models are developed to per-form the long-term monitoring of the stability of Aqua MODIS TEBs. Long-term EuropeanCentre for Medium-Range Weather Forecasts global atmospheric reanalysis data are used asinputs to the RTM simulation. By confining ocean in low to middle latitudes as the area ofinterest, the long-term stabilities of Aqua MODIS TEBs are monitored through observationminus background (O-B) brightness temperature (BT) bias between MODIS measurements andsimulations from the RTM. In general, the RTM-based O-B analysis shows that the long-termstability of Aqua MODIS TEBs are maintained well. It is shown that Aqua MODIS surfacebands are all radiometrically stable with yearly BT bias drifts <0.005 K∕yearfor B20, B22,and B23 and∼0.01 K∕yearfor B31 and B32. The carbon dioxide (CO2) absorption channelsof Aqua MODIS, e.g., B33 to B36, are stable with a BT bias drift <0.005 K∕year. It is also foundthat after accounting for the long-term growth of greenhouse gasN2O, the O-B bias trends forB24 and B25 are quite stable with yearly BT bias drifts around 0.0002 and0.0055 K∕year,respectively. The stabilities of the moisture-sensitive channels B27 to B29 and the ozone channelB30 of Aqua MODIS are also evaluated and the remnant small variations in the O-B bias trend-ing of these channels are further discussed. The RTM-based inter-comparison of MODIS TEBmeasurements with global atmospheric and climate re-analysis data provides validation of thelong-term radiometric stability of Aqua MODIS TEBs. The analysis in this paper also demon-strates that the comparison of well-calibrated MODIS TEB measurements with RTM simulationhelps quantify the long-term impacts of global greenhouse gas concentration growth on the BTdecreases in the MODIS greenhouse gas-sensitive channels.

MODIS↗

On-Orbit Calibration and Performance Assessments of Terra and Aqua Modis Thermal Emissive Bands

Terra and Aqua MODIS have successfully operated for more than 20 and 18 years, respectively, and far exceeded their designed lifetimes of 6 years. MODIS has 36 spectral bands, among which 16 are the thermal emissive bands (TEB) covering a wavelength range from 3.75 to 14.24 μm. Observations from the MODIS TEB have been used to generate a number of data products, such as surface/cloud/atmospheric temperatures, cloud top altitude, and water vapor properties. To a large extent, the quality of the MODIS L1B radiance product has been maintained through the entirety of each mission via extensive on-orbit calibration and validation efforts. MODIS TEB calibration uses a quadratic algorithm and is referenced to an on-board blackbody with its temperature measurements traceable to the NIST standard. We provide an overview of the MODIS instrument operations, key TEB calibration activities, and algorithms used in the latest L1B data Collection 6.1 (C6.1) and describe the TEB on-orbit performance for both Terra and Aqua MODIS. The TEB gain trends have been stable to within 5% over the Terra mission after 2003 under the same electronic configuration, except for bands 27 to 30, and within 3% over the Aqua mission. The Terra MODIS optical crosstalk correction implemented right after launch has been very effective in removing the ghost images in its photoconductive detector bands 32 to 36. Starting from C6.1, an electronic crosstalk correction algorithm has also been applied to the Terra MODIS photovoltaic detector long-wave infrared bands 27 to 30. The noise characterization performance remains stable with most TEB detectors continuously meeting their design requirements. A gradual loss of the Aqua MODIS radiative cooler margin reached its maximum in 2013 and has been slowly recovering since then. On-orbit changes in TEB response versus scan angle are extremely small based on pitch maneuver observations and assessments using vicarious approaches. The remaining challenges in TEB calibration and proposed improvements for the upcoming data collection with L1B data production and reprocessing are discussed.

Terra↗

Sensor Calibration Impacts on Dust Detection Based On MODIS And VIIRS Thermal Emissive Bands

Dust detection using remotely sensed measurements has been one of the challenging problems encountered by atmospheric scientists. MODerate Resolution Imaging Spectroradiometer (MODIS) on the Terra (T)and Aqua (A) platforms have been a versatile sensor for well over 21 and 18 years respectively and have been extremely useful in the retrieval of aerosol information over the entire globe. The MODIS radiances from the Level1B in general are expected to be within 5% accuracy in the reflective wavelengths and within 1% in the thermal emissive wavelengths. In this paper, we evaluate the sensitivity of previously developed dust detection technique based on thermal emissive wavelengths, which correspond to MODIS bands 20, 29, 31, and 32 respectively. The Thermal Emissive Dust Index (TEDI) performed very comparably to the traditional Aerosol Optical Thickness (AOT) retrievals by MODIS reflective channels. Since the MODIS Thermal Emissive Bands (TEB) are well calibrated on-orbit using a BlackBody (BB) source, the calibration of these long wave infrared bands is quite robust. As A-MODIS continues to perform well beyond its designed lifetime of 6 years, the instrument has undergone various levels of degradation during its mission time. As a consequence, it is imperative to check the impacts of calibration on the higher-level retrievals. In this paper, we rigorously analyze the sensitivity of TEDI due to the impact of calibration by the afore-mentioned TEB. The perturbation of the dominant (linear) calibration term demonstrated the following: first, there was a correlation in the sensitivity of the TEDI due to the uncertainty in the linear calibration term. Based on a perturbation in the linear calibration term for all aforementioned bands over a range of ± 5 % yielded the TEDI sensitivity to vary from approximately -3.2 % to about -3.6 %. When considering the uncertainty in each individual band significant changes were observed. The least change was observed for the perturbation in the calibration of band 20 with the TEDI sensitivity and the largest sensitivity in TEDI was observed in the perturbation of band 31 calibration. Thus, in the case of TEDI, noticeable sensitivity due to calibration uncertainty was observed in bands 29, 31, and 32, reiterating the importance of the TEB calibration in these bands. Also, the dust detection scheme based on A-MODIS was successfully transferred to the follow-on sensors such as Suomi (SNPP) and NOAA 20 (N20) VIIRS. The results presented in this paper would be extremely helpful in understanding impacts of calibration on the higher-level products for both current and future missions based on the MODIS heritage. Finally, the work also identifies the importance of radiometric fidelity in maintaining the accuracy of the dust detection. Results presented will show drastic improvement of the Saharan dust detection after the reduction of the electronic crosstalk in the 8.5 μm channel of T-MODIS.

Sriharsha Madhavan↗

NOAA-20 VIIRS Reflective Solar bands on-Orbit Calibration Using a Hybrid Approach

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) has been in orbit for more than two and a half years. VIIRS has 22 bands, among which 14 are reflective solar bands (RSBs) covering a spectral range from 0.41 to 2.25 μm. The RSBs are calibrated on-orbit using an onboard solar diffuser (SD), on-orbit degradation of which is tracked by an onboard SD stability monitor (SDSM). NOAA-20 VIIRS is also scheduled to view the Moon approximately monthly and the lunar observations are used to track the RSB on-orbit changes as well. Both SD and lunar calibration results for the RSBs are shown and it is demonstrated that the two sets of the calibration coefficients diverge with time, especially at short wavelengths. The divergence is due to the non-uniformity of the SD degradation, which results in a long-term bias in the calibration coefficients derived from the SD calibration. A hybrid method, which properly combines the SD and lunar calibration results, is applied to generate the RSB calibration coefficients as has been done for SNPP VIIRS RSBs. The hybrid results have both the accuracy and frequency and ensure the high quality of the VIIRS sensor data records (SDR).

Calibration↗

Crosstalk Effect in NOAA 20 VIIRS Thermal Emissive Bands

Crosstalk contamination in the Moderate Resolution Imaging Spectroradiometer (MODIS) thermal emissive bands (TEBs) has been a known issue since prelaunch, that has amplified on-orbit for some of bands. A linear algorithm has been developed and successfully applied to mitigate the crosstalk effect and restore the quality and accuracy of the MODIS L1B products. Significant crosstalk effect has also been found and characterized in TEBs of the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership (SNPP). NOAA-20 VIIRS, a follow-on instrument to SNPP VIIRS, was launched on November 18, 2017. In this report, it is shown that there are nonnegligible crosstalk contaminations among the TEBs of NOAA-20 VIIRS as well. They are characterized using the scheduled lunar observations and compared with those in SNPP VIIRS.

Calibration↗

Positional Dependence of SNPP VIIRS Solar Diffuser BRDF Change Factor: An Empirical Approach

The Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly performs on-orbit radiometric calibration of its reflective solar bands (RSBs), primarily through observations of an onboard sunlit solar diffuser (SD). The on-orbit change of the SD bidirectional reflectance distribution function (BRDF) value, quantified by a numerical factor called the H-factor, is determined by the onboard SD stability monitor. Our previous study showed that the H-factor is solar angle and view direction dependent. In this study, we determine the dependence of the H-factor on the detector SD view footprint location. We fit an empirical model to the NASA Collection 1 SNPP VIIRS Level 1B (L1B) spectral reflectance difference across the detectors in an RSB over uniform Earth scenes of the Libya 4 desert and deep convective clouds. We apply the model predicted SD positional dependent H-factor to calibrate the RSBs. Under this new calibration scheme, the original unreal striping is removed from the homogeneous Libya 4 desert and the deep convective cloud images, as well as the original unreal striping from the Dunhuang desert image. The SD positional dependent H-factor has been used to calculate the SNPP VIIRS RSB radiometric correction factor for the NASA Collection 2.0 SNPP VIIRS L1B products.

SNPP VIIRS↗

Improvements of On-orbit Characterization of Terra MODIS Short-wave Infrared Spectral Bands Out-of-Band Responses

The short-wave infrared (SWIR) bands (5-7, 26) of Terra MODIS, which are co-located with the mid-wav e infrared (MWIR) bands (20-25) on the short and mid-wave infrared (SMIR) Focal Plane Assembly (FPA),have a known issue related to 5.3 μm out-of-band (OOB) thermal leak and electronic crosstalk that was identified prelaunch. As a result, a crosstalk correction algorithm was designed and implemented in the MODIS Level 1B (L1B) calibration. Shortly after the Terra launch, extensive efforts were under taken to help characterize and mitigate the impact due to the OOB response and crosstalk on the SWIR on-orbit calibration and, consequently, the associated L1Bdata products. In addition, special night time day mode (NTDM) operations have been regularly scheduled to derive the crosstalk correction coefficients. Since MODIS does not have a spectral band centered at 5.3 μm, its band 28 (7.325 μm) was chosen as the surrogate sending band to simulate the OOB radiances at 5.3 μm. This was largely based on the measurements from the MODIS Airborne Simulator (MAS) spectrometer field campaigns in the early months after the Terra launch. In the case of Aqua MODIS, the magnitude of the SWIR crosstalk was much smaller and band 25 (4.52 μm) was found to be more effective as the sending band for the crosstalk correction. In recent years, the Terra MODIS photovoltaic (PV) long-wave infrared (LWIR) bands (27-30)electronic crosstalk has increased considerably, especially after the spacecraft safe-mode event occurred in February2016. This accentuated degradation in the PV LWIR performance has also impacted the performance of the SWIR crosstalk correction and thus its calibration and data quality. In this paper, we examine the use of band 25 as the sending band for the Terra MODIS SWIR crosstalk correction and compare its performance with that based on band 28 as the sending band. Results indicate an improvement of on-orbit gain stability for the SWIR calibration and reduced detector to detector and sub-frame to sub-frame striping in the calibrated L1B imagery, especially during the period when the PV LWIR electronic crosstalk has become more severe. This approach has been implemented in the forward production of Terra MODIS Collection 6 and Collection 6.1,starting from July 2019, and is planned to be used for the future reprocessing of MODIS L1B and to help improve the mission-long reflectance calibration and trending stability of the SWIR bands.

MODIS, Terra, Aqua, MODIS, SWIR, calibration, out-↗

Performance of NOAA-20 VIIRS Solar Diffuser and Solar Diffuser Stability Monitor

Visible Infrared Imaging Radiometer Suite (VIIRS) radiometrically calibrates its reflective solar bands (RSBs) primarily through a sunlit onboard solar diffuser (SD). The sunlit SD provides a known radiance under the condition that the absolute product of the SD screen transmittance and the bidirectional reflectance distribution function (BRDF) along the SD-to-telescope direction is accurately known. The BRDF changes due to solar exposure. The change, referred to as the H-factor, is monitored by the onboard SD stability monitor (SDSM). The accuracy of the retrieved H-factor propagates to the retrieved F-factor which corrects the scene spectral radiance. High accuracy of the retrieved H-factor relies on high accuracies in the SDSM screen relative effective transmittance and the relative product of the SD screen effective transmittance and the BRDF at the mission start, and a high SDSM detector signal-to-noise ratio (SNR). This article briefly reviews the algorithms used for the NOAA-20 (N20) VIIRS RSB on-orbit radiometric calibration. Additionally, we show the performance of the N20 VIIRS SDSM, giving the SDSM detector SNRs and the SDSM detector gain temporal changes. We develop a model for the SNRs. The model shows that the decreased SNRs in time are due to the detector gain decreases. We also show the N20 VIIRS SD on-orbit performance, measured by the retrieved H-factor and the estimated standard deviation of its error. The H-factor for the telescope view is obtained from the H-factor for the SDSM view, multiplied by an H-factor angular dependence term. We use an innovative method to determine the angular dependence, using the dependence obtained for the Suomi National Polar-orbiting Partnership (SNPP) VIIRS.

VIIRS↗

Assessments of S-NPP and N20 VIIRS DNB and M bands calibration stability and consistency using a homogeneous ground target

The S-NPP and N20 VIIRS Day-Night band (DNB) and M bands top-of-atmosphere (TOA) radiance and reflectance are calculated and a kernel-driven Bidirectional Reflectance Distribution Function (BRDF) correction model is used to correct the surface and atmosphere combined BRDF influence. Due to degradation in the DNB modulated Relative Spectral Response (RSR), the S-NPP VIIRS observed TOA DNB reflectance indicates a decrease of 1.89% and the SCIAMACHY spectra derived TOA DNB reflectance has a decrease of 1.63% for the past 8.5 years. The N20 VIIRSTOA DNB reflectance decreased 0.50% in the past 2.5 years. The DNB radiance is also compared with the integral of the M bands radiance from M4, M5, and M7. The fitting trends of DNB to the integral of M bands ratios indicate a0.48% decrease for S-NPP VIIRS and 0.14% increase for N20 VIIRS. The N20 VIIRS DNB to integral M bands ratios are closer to 1 than the S-NPP VIIRS data. The BRDF corrected reflectance comparisons show that the N20 VIIRS data is slightly lower than those of S-NPP VIIRS. The averages of the linear fit values of the N20 to S-NPP VIIRS from 2018to 2020 June are -1.97%, -4.99%, -3.36%, and -0.85% for M4, M5, M7, and DNB, respectively. Our results indicate that the S-NPP and N20 VIIRS DNB and M bands calibration have been stable. The cross-sensor differences in DNB and M bands are generally consistent with other independent studies using similar and different approaches.

Libya 4↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part I: The algorithms

The first VIIRS instrument is aboard the Suomi National Polar-orbiting Partnership satellite. The instrument has 14 reflective solar bands (RSBs) to passively collect photons reflected from the Earth surface in the design wavelengths from 412 to 2250 nm. The instrument uses a solar diffuser (SD) to radiometrically calibrate its RSBs. When lit by the Sun through an attenuation screen (the SD screen), the SD diffusely reflects off the incident sunlight to act as a radiance source for the calibration. An onboard solar diffuser stability monitor (SDSM) yields the on-orbit change of the SD bidirectional reflectance distribution function (BRDF) by comparing the signal strength from the SD with that from the Sun attenuated by another attenuation screen (the SDSM screen). Complications arise due to the discovery that the on-orbit change of the BRDF is angle dependent. Additionally, the SDSM does not cover the wavelengths for the short-wave infrared bands in the RSBs. Furthermore, satellite yaw maneuvers were performed in the early mission to yield data for refining the prelaunch SDSM screen relative effective transmittance and the relative product of the SD screen transmittance and the BRDF at the mission start. But the yaw maneuver data are coarse in the solar azimuth angles and thus are unable to yield accurate values between the measurement angles. Over the years of performing on-orbit radiometric calibration through the SD for the VIIRSRSBs, we have developed several highly effective calibration algorithms to address the issues mentioned above. This paper reviews these algorithms.

on-orbit cailbration↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part II: The performances

In Part I (Lei et. al, submitted to J. of Appl. Rem. Sens.),we gave detailed reviews of the algorithms Version 2.0 used for the on-orbit radiometric calibration of the reflective solar bands (RSBs) of the first Visible Infrared Imaging Radiometer Suite instrument. These algorithms improve the accuracy of the measured on-orbit change factor of the solar diffuser bidirectional reflectance distribution function, the H-factor, and reveal that the H-factor is angle dependent. With the help of lunar observations and the improved H-factor, the algorithms give more accurate values for the RSB detector on-orbit F-factor changes (F-factor is a correction factor to the initially retrieved scene spectral radiance). In this paper we review the RSB radiometric calibration performances. We show the H-factor temporal trend, the estimated uncertainty of the retrieved H-factor, and the F-factor temporal trend. Additionally we show the detector signal-to-noise ratio (SNR), the estimated uncertainty of the top-of-the-atmosphere solar spectral reflectance, the reflectance temporal trend for the Libya 4 desert, and the differences in the reflectances among the SNPP and the NOAA-20 VIIRS, and the Aqua MODIS. Our results show that although the SNRs trend downwards, they exceed the requirements by large margins. The reflectances from the Libya 4 desert show that the SNPP VIIRS’ reflectance is higher than those of the Aqua MODIS and the NOAA-20 VIIRS.

on-orbit calibration↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part I: The algorithms

The first VIIRS instrument is aboard the Suomi National Polar-orbiting Partnership satellite. The instrument has 14 reflective solar bands (RSBs) to passively collect photons reflected from the Earth surface in the design wavelengths from 412 to 2250 nm. The instrument uses a solar diffuser (SD) to radiometrically calibrate its RSBs. When lit by the Sun through an attenuation screen (the SD screen), the SD diffusely reflects off the incident sunlight to act as a radiance source for the calibration. An onboard solar diffuser stability monitor (SDSM) yields the on-orbit change of the SD bidirectional reflectance distribution function (BRDF) by comparing the signal strength from the SD with that from the Sun attenuated by another attenuation screen (the SDSM screen). Complications arise due to the discovery that the on-orbit change of the BRDF is angle dependent. Additionally, the SDSM does not cover the wavelengths for the short-wave infrared bands in the RSBs. Furthermore, satellite yaw maneuvers were performed in the early mission to yield data for refining the prelaunch SDSM screen relative effective transmittance and the relative product of the SD screen transmittance and the BRDF at the mission start. But the yaw maneuver data are coarse in the solar azimuth angles and thus are unable to yield accurate values between the measurement angles. Over the years of performing on-orbit radiometric calibration through the SD for the VIIRSRSBs, we have developed several highly effective calibration algorithms to address the issues mentioned above. This paper reviews these algorithms.

Ning Lei↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part II: The performances

In Part I (Lei et. al, submitted to J. of Appl. Rem. Sens.),we gave detailed reviews of the algorithms Version 2.0 used for the on-orbit radiometric calibration of the reflective solar bands (RSBs) of the first Visible Infrared Imaging Radiometer Suite instrument. These algorithms improve the accuracy of the measured on-orbit change factor of the solar diffuser bidirectional reflectance distribution function, the H-factor, and reveal that the H-factor is angle dependent. With the help of lunar observations and the improved H-factor, the algorithms give more accurate values for the RSB detector on-orbit F-factor changes (F-factor is a correction factor to the initially retrieved scene spectral radiance). In this paper we review the RSB radiometric calibration performances. We show the H-factor temporal trend, the estimated uncertainty of the retrieved H-factor, and the F-factor temporal trend. Additionally we show the detector signal-to-noise ratio (SNR), the estimated uncertainty of the top-of-the-atmosphere solar spectral reflectance, the reflectance temporal trend for the Libya 4 desert, and the differences in the reflectances among the SNPP and the NOAA-20 VIIRS, and the Aqua MODIS. Our results show that although the SNRs trend downwards, they exceed the requirements by large margins. The reflectances from the Libya 4 desert show that the SNPP VIIRS’ reflectance is higher than those of the Aqua MODIS and the NOAA-20 VIIRS

Ning Lei↗

The MODIS RSB calibration and look-up-table delivery process for Collection 6 and 6.1

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on-board the Aqua and Terra space-craft have provided valuable science data for the last 18 and 20 years, respectively. Each instrument is equipped with 36 spectral bands, 20 of which are reflective solar bands (RSBs). These bands cover a wavelength range of 0.4 – 2.2μm and are calibrated on-orbit using several on-board calibrators (OBCs), such as a solar diffuser (SD)and a solar diffuser stability monitor (SDSM), along with regularly-scheduled lunar observations through the space view (SV) port. The gain (1/m1) and response-verses-scan angle (RVS) are updated on a near-monthly basis and act as the primary look-up-tables (LUTs) for the RSB calibration. A set of separate uncertainty LUTs for each of the RSBs are also delivered regularly and incorporated into the Level 1B (L1B) product to generate a pixel-level Uncertainty Index (UI). In addition to the gain, RVS and uncertainty, there are several other LUTs associated with the reflective bands that are either updated less frequently or remain static. The accuracy of both the forward-predicted and historical RSB LUTs, which are derived by the MODIS Characterization Sup-port Team (MCST), is important in maintaining the quality and accuracy of the L1B and science products.To ensure a timely and accurate LUT update, MCST has established a comprehensive set of procedures. This paper provides an overview of the calibration process, along with the current LUT delivery process for the RSB sin Collection 6 (C6) and Collection 6.1 (C6.1). Improvements to be implemented in future collections are also discussed.

MODIS↗

Application of quasi-deep convective clouds method for MODIS and VIIRS TEB calibration assessments

A technique to use deep convective clouds (DCC) and quasi-DCC (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has proven feasible. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit black body (BB) warm-up and cool-down (WUCD) activities for updates. However, the limited BB temperature range affects the calibration’s uncertainty. The DCC core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide the advantage of removing solar reflectance effects, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, the qDCC method is applied to the Terra MODIS and VIIRS TEB. Their stabilities are assessed using long-term DCC and qDCC trending measurements over the instruments’ entire missions. The measurements from bands with an approximately 11-μm wavelength are used to identify the DCC pixels. MODIS band31 (~ 11m) has demonstrated stable performance and accurate calibration for both instruments throughout their respective missions. MODIS band31 can therefore be used as a reference for the other TEB. Furthermore, it also allows for a Terra and Aqua MODIS TEB cross-comparison. The assessment results, along with the calibration uncertainty and Level 1B product impact modeling, can be quite helpful for calibration improvements.

MODIS↗

MODIS and VIIRS Calibration and Characterization in Support of Producing Long-Term High-Quality Data Products

Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) have successfully operated since their launches in 1999 and 2002, respectively, and generated various data products to support the Earth remote sensing disciplines and users worldwide for their research activities and applications, including studies of the Earth system, and its changes over time and geographic regions. The MODIS data have also significantly contributed to the continuity of multi-decadal satellite data records and led to major advances in the Earth remote sensing field. The long-term data records from MODIS observations have been and will continue to be extended by the Visible Infrared Imaging Radiometer Suite (VIIRS) instruments, currently operated aboard the Suomi-National Polar-Orbiting Partnership (NPP) and NOAA-20 satellites. The data quality of satellite instruments strongly depends on their calibration accuracy and stability. In order to help scientists and users gain a better understanding of MODIS and VIIRS data quality, this paper provides an overview of their on-orbit calibration methodologies, approaches, and results derived from instrument on-board calibrators and lunar observations, as well as select Earth view targets. What is also discussed is the calibration consistency between MODIS and VIIRS and its potential impact on producing multi-sensor long-term data records. As illustrated, the overall performance of both MODIS and VIIRS continues to meet their design requirements.

MODIS↗

MODIS Detector Differences Using Deep Convective Clouds and Desert Targets

An accurate on-orbit characterization of the Moderate Resolution Imaging Spectroradiometer (MODIS) sensors onboard the Terra and Aqua satellites is essential to satisfy the requirements from the scientific community for high-quality operational and research products. In this study, NASA’s C6.1 L1B data are utilized to assess the stability of the calibrated top of atmosphere reflectance retrieved from individual detectors within a spectral band over deep convective clouds (DCCs) and desert sites. The results from these invariant Earth targets show detector-to-detector (D2D) differences in the L1B reflectance products for select MODIS reflective solar bands. For Aqua MODIS, the D2D differences have no significant change over time for the bands studied. However, the D2D differences exhibit an increase in magnitude over time for Terra MODIS bands 1, 3-7, and 26, which can induce noticeable striping and higher uncertainties in the downstream data products. The D2D stability assessment results over DCCs are consistent with those observed over desert sites. In addition, the view-angle dependence of the D2D differences is investigated by separating the frames along scan into five zones. The D2D assessment is performed for each of the five zones, and the results will further benefit any improvements in the calibration of a detector-dependent response versus scan angle that can be considered for future MODIS Level 1B Collections.

MODIS↗