Engineering PapersSearch

Engineering topics

Waters, J. W.

Publications and source records attributed to Waters, J. W..

At least 55 records · Page 3

Validation of UARS Microwave Limb Sounder Temperature and Pressure Measurements

The accuracy and precision of the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS) atmospheric temperature and tangent-point pressure measurements are described. Temperatures and tangent- point pressure (atmospheric pressure at the tangent height of the field of view boresight) are retrieved from a 15-channel 63-GHz radiometer measuring O2 microwave emissions from the stratosphere and mesosphere. The Version 3 data (first public release) contains scientifically useful temperatures from 22 to 0.46 hPa. Accuracy estimates are based on instrument performance, spectroscopic uncertainty and retrieval numerics, and range from 2.1 K at 22 hPa to 4.8 K at 0.46 hPa for temperature and from 200 m (equivalent log pressure) at 10 hPa to 300 m at 0.1 hPa. Temperature accuracy is limited mainly by uncertainty in instrument characterization, and tangent-point pressure accuracy is limited mainly by the accuracy of spectroscopic parameters. Precisions are around 1 K and 100 m. Comparisons are presented among temperatures from MLS, the National Meteorological Center (NMC) stratospheric analysis and lidar stations at Table Mountain, California, Observatory of Haute Provence (OHP), France, and Goddard Spaceflight Center, Maryland. MLS temperatures tend to be 1-2 K lower than NMC and lidar, but MLS is often 5 - 10 K lower than NMC in the winter at high latitudes, especially within the northern hemisphere vortex. Winter MLS and OHP (44 deg N) lidar temperatures generally agree and tend to be lower than NMC. Problems with Version 3 MLS temperatures and tangent-point pressures are identified, but the high precision of MLS radiances will allow improvements with better algorithms planned for the future.

Fishbein, E. F.

Validation of UARS Microwave Limb Sounder Ozone Measurements

This paper describes the validation of ozone data from the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS). The MLS ozone retrievals are obtained from the calibrated microwave radiances (emission spectra) in two separate bands, at frequencies near 205 and 183 GHz. Analyses described here focus on the MLS Version 3 data (the first set of files made publicly available). We describe results of simulations performed to assess the quality of the retrieval algorithms, in terms of both mixing ratio and radiance closure. From actual MLS observations, the 205-GHz ozone retrievals give better closure (smaller radiance residuals) than that from the 183-GHz measurements and should be considered more accurate from the calibration aspects. However, the 183-GHz data are less noise limited in the mesosphere and can provide the most useful scientific results in that region. We compare the retrieved 205-GHz ozone profiles in the middle-to lower stratosphere to ozonesonde measurements at a wide range of latitudes and seasons. Ground-based lidar data from Table Mountain, California, provide a good reference for comparisons at higher altitudes. Based on these analyses, comparisons with balloon-borne measurements and others, as well as a detailed budget of estimated uncertainties, MLS results appear to be generally of high quality, with some biases worth mentioning. Results for the lowermost stratosphere (approx. 50 to 100 bPa) are still in need of improvement. A set of estimated precision and accuracy values is derived for the MLS ozone data sets. We also comment on recent updates in the retrieval algorithms and their impact on ozone values.

Froidevaux, L.

Validation of UARS Microwave Limb Sounder ClO Measurements

Validation of stratospheric ClO measurements by the Microwave Limb Sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) is described. Credibility of the measurements is established by (1) the consistency of the measured ClO spectral emission line with the retrieved ClO profiles and (2) comparisons of ClO from MLS with that from correlative measurements by balloon-based, ground-based, and aircraft-based instruments. Values of "noise" (random), "scaling" (multiplicative), and "bias" (additive) uncertainties are determined for the Version 3 data, in the first version public release of the known artifacts in these data are identified. Comparisons with correlative measurements indicate agreement to within the combined uncertainties expected for MLS and the other measurements being compared. It is concluded that MLS Version 3 ClO data, with proper consideration of the uncertainties and "quality" parameters produced with these data, can be used for scientific analyses at retrieval surfaces between 46 and 1 hPa (approximately 20-50 km in height). Future work is planned to correct known problems in the data and improve their quality.

Waters, J. W.

Validation of UARS Microwave Limb Sounder 183 GHz H2O Measurements

The Upper Atmosphere Research Satellite (UARS) microwave limb sounder (MLS) makes measurements of thermal emission at 183.3 GHz which are used to infer the concentration of water vapor over a pressure range of 46-0.2hPa (approximately 20-60 km). We provide a validation of MLS H2O by analyzing the integrity of the measurements, by providing an error characterization, and by comparison with data from other instruments. It is estimated that version 3 MLS H2O retrievals are accurate to within 20-25% in the lower stratosphere and to within 8-13% in the upper stratosphere and lower mesosphere. The precision of a single profile is estimated to be approximately 0.15 parts per million by volume (ppmv) in the midstratosphere and 0.2 ppmv in the lower and upper stratosphere. In the lower mesosphere the estimate of a single profile precision is 0.25-0.45 ppmv. During polar winter conditions, H2O retrievals at 46 hPa can have a substantial contribution from climatology. The vertical resolution of MLS H2O retrievals is approximately 5 km.

Lahoz, W. A.

Calibration of the Microwave Limb Sounder on the Upper Atmosphere Research Satellite

The Microwave Limb Sounder (MLS) is a three-radiometer, passive, limb emission instrument onboard the Upper Atmosphere Research Satellite (UARS). Radiometric, spectral and field-of-view calibrations of the MLS instrument are described in this paper. In-orbit noise performance, gain stability, spectral baseline and dynamic range are described, as well as use of in-flight data for validation and refinement of prelaunch calibrations. Estimated systematic scaling uncertainties (3 sigma) on calibrated limb radiances from prelaunch calibrations are 2.6% in bands 1 through 3, 3.4% in band 4, and 6% in band 5. The observed systematic errors in band 6 are about 15%, consistent with prelaunch calibration uncertainties. Random uncertainties on individual limb radiance measurements are very close to the levels predicted from measured radiometer noise temperature, with negligible contribution from noise and drifts on the regular in-flight gain calibration measurements.

Jarnot, R. F.

Observations of Gravity Waves with the UARS Microwave Limb Sounder

From Introduction: Observations (of gravity waves-GW) from radar, lidar, balloon and rocket yield good temporal and vertical resolutions usually at one geographical location while aircraft observations provide good horizontal resolution but for a short period of time. It is difficult in general for space-borne sensors to obtain the same resolutions, but observations of GWs at somewhat larger scales are feasible, for example using saturated radiances from the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS)[Wu and Waters, 1996].

climatology MLS

Excitation and Evolution of the Quasi-2-Day Wave Observed UARS/MLS Temperature Measurements

The quasi-2-day wave is known as a strong and transient perturbation in the middle and upper atmosphere that often occurs shortly after solstice. The excitation mechanisms of this transient wave have been discussed for years, but no clear answer has yet been attained. In this paper, propagating characteristics of the 2-day wave are studied based on 8-mon temperature measurements from the Microwave Limb Sounder onboard the Upper Atmosphere Research Satellite. The studies are focused on the wave events that happened in January 1993 and in July-August 1993. The observations suggest that winter planetary waves could be responsible for triggering the summer 2-day wave through long penetration into the summer stratosphere. A connection is evident in the evolution of the wave amplitude between the summer 2-day wave generation and winter wave penetration. The data also suggest that the enhancement of the wave amplitude is a manifestation of both a local unstable wave and a global normal-mode Rossby wave.

Wu, D. L.

Arctic Ozone Depletion Observed by UARS MLS During the 1994-95 Winter

During the unusually cold 1994-95 Arctic winter, the Microwave Limb Sounder observed enhanced chlorine monoxide (ClO) in late Dec and throughout Feb and early Mar. Late Dec ClO was higher than during any of the previous 3 years, consistent with the colder early winter. Between late Dec 1994 and early Feb 1995, 465 K (about 50 hPa) vortex-averaged ozone (03) decreased by about 15%, with local decreases of about 30%; additional local decreases of about 5% were seen between early Feb and early Mar. Transport calculations indicate that vortex-averaged chemical loss between late Dec and early Feb was about 20% at 465 K, with about 1/4 of that masked by downward transport of O3. This Arctic chemical O3 loss is not readily detectable in MLS column O3 data.

Manney, G. L.

Validation of UARS MLS 183 GHz H(sub 2)O Measurements

We provide a validation of MLS H(sub 2)O by analyzing the integrity of the measurements, by providing an error characterization and by comparison with data from other instruments. This paper concerns the data validation of middle atmosphere distributions of H(sub 2)O as measured by the Midrowave Limb Sounder (MLS).

thermal emission UARS energy balance of the middle

Atmospheric Measurements by the MLS Experiments: Results from UARS and Plans for EOS

The Microwave Limb Sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) has provided measurements of O(sub 3), H(sub 2)O, CIO, SO(sub 2), HNO(sub 3), temperature and pressure in Earth's atmosphere. These measurements are made near-globally both dat and night and are not degraded by the presence of aerosols, cirrus or polar sratospheric clouds.

Microwave Limb Sounder MLS Upper Atmosphere Resear

Polar Vortex Conditions During the 1995-96 Arctic Winter: MLS CL0 and HNO(sub 3)

Microwave Limb Sounder (MLS) measurements of lower stratospheric CLO and HNO(sub 3) during the 1995-96 Arctic winter are presented. The 1995-96 Arctic winter was both colder and more persistently cold than usual, leading to an enhancement in lower stratospheric CLO of greater magnitude, vertical extent, and duration than has been previously observed in the Arctic. Vortex concentrations of HNO(sub 3) in mid-December were large due to diabetic decent. Trajectory calculations indicate that localized severe depletions of gas-phase HNO(sub 3) in mid-February and early March did not arise from intrainment of midlatitude air into the vortex and were therefore probably related to polar stratospheric cloud (PSC) formation.

Microwave Limb Sounder MLS CLO HNO3

Validation of UARS Microwave Limb Sounder Temperature and Pressure Measurements

The accuracy and precision of the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS) atmospheric temperature and tangent-point pressure measurements are described. Temperatures and tangent-point pressure are retrieved from a 15-channel 63-GHz radiometer measuring O 2 microwave emissions from the stratosphere and mesosphere.

atmospheric

Evidence for Arctic Ozone Depletion in Late February and early March 1994

Significant chemical ozone (O3 ) loss in the 1993-94 Arctic winter occurred mainly during an unusually late cold spell of approximately 10 days in late Feb/early Mar. Over the 30 d period studied (including the cold spell), observed vortex-averaged O3 at 465 K (approximately 40 hPa) decreased by approximately 10%. New three-dimensional, diabatic trajectory calculations show that this observed decrease represents only about half of the net chemical loss (approximately 20%) during the 30 day period. The resupply of lower stratospheric O3 by transport in Feb 1994 was considerably greater than in 1993, when transport masked only about a quarter of the chemical loss in Feb/Mar. The net estimated chemical loss over 30 days in 1994 was comparable to that over the same 30 days in 1993, but mainly occurred at a faster rate during the brief cold spell. These results highlight the impact of Arctic interannual variability on the relative roles of chemistry and dynamics in O3 evolution during recent Arctic winters.

Manney, G. L.

Lagrangian Transport Calculations Using UARS Data: Ozone - Part 2

Trajectory calculations are used to examine ozone transport in the polar winter stratosphere during periods of the Upper Atmosphere Research Satellite (UARS) observations. The value of these calculations for determining mass transport was demonstrated previously using UARS observations of long-lived tracers, In the middle stratosphere, the overall ozone behavior observed by the Microwave Limb Sounder in the polar vortex is reproduced by this purely dynamical model. Calculations show the evolution of ozone in the lower stratosphere during early winter to be dominated by dynamics in December 1992 in the Arctic. Calculations for June 1992 in the Antarctic show evidence of chemical ozone destruction and indicate that approx. 50% of the chemical destruction may be masked by dynamical effects, mainly diabatic descent, which bring higher ozone into the lower-stratospheric vortex. Estimating differences between calculated and observed fields suggests that dynamical changes masked approx. 20% - 35% of chemical ozone loss during late February and early March 1993 in the Arctic. In the Antarctic late winter, in late August and early September 1992, below approx. 520 K, the evolution of vortex-averaged ozone is entirely dominated by chemical effects; above this level, however, chemical ozone depletion can be partially or completely masked by dynamical effects. Our calculations for 1992 showed that chemical loss was nearly completely compensated by increases due to diabatic descent at 655 K.

Manney, Gloria L.