SU-E-T-308: Dosimetric Comparison of SBRT VMAT Treatment Plans Generated for 6 MV, 6 MV FFF, and 10 MV FFF Photon Beams

Purpose: To assess differences in treatment plan quality between VMAT stereotactic body plans generated using the 6 MV, 6 MV FFF, and 10 MV FFF modalities available in our clinic. Plans for lung, spine, and other sites were compared to see if there is any advantage of one modality over the other. Methods: Treatment plans done for actual SBRT patients were selected. Groups of ten lung plans, five spine plans, and five plans from other sites were selected. New treatment plans were generated for each plan using the Varian Eclipse AAA algorithm. The constraints were kept the same as used in the actual plans, but the same version of software was used to generate plans for the three modalities. In addition, because there are natural variations in plans re-done with the same dose constraints, one of the lung plans was repeated ten times to assess those differences. Volumes of the 100%, 90%, 50%, 20% and 10% isodose surfaces were compared. Maximum dose two centimeters from the PTV were compared, as well as the volume of the 105% isodose surface outside of the PTV. In addition, the 20 Gray lung volume was compared for the lung plans. The values of these parameters were divided by the values for the 6 MV plans for comparison. Average and standard deviations were obtained for quantities in each group. The Student t test was done to determine if differences were seen at the 95% confidence level. Results: Comparison of the treatment plans showed no significant differences when assessing these volumes and doses. There were not any trends seen when comparing modalities as a function of PTV volume either. Conclusion: There is no obvious dosimetric advantage in selection of one modality over another for these types of SBRT plans.

60 APPLIED LIFE SCIENCES↗

SU-E-T-323: Dosimetric Evaluation of Small Fields for SBRT Treatment

Purpose: Stereotactic body radiation therapy (SBRT) is commonly employed to treat small targets for effective tumor control with radiation beams of small field sizes. The goal of this work was to evaluate dosimetrically a treatment planning system (TPS) by comparing the calculated dose for SBRT treatment with ion-chamber measurements. Methods: 3D images of a solid-water phantom with a pinpoint ion-chamber (0.015cm3) inside were acquired with a CT scanner. Active volume of the ion-chamber was delineated on CT images. Targets with a diameter of 1.5cm, 2cm, 3cm, 4cm and 5cm were drawn around the chamber. 3DCRT plans were generated for each target size with centrally opened 6MV beams and off-axis beams by changing the isocenter location, respectively, using a TPS with the Analytical Anisotropic Algorithm. A 21iX linear accelerator was employed for plan delivery. The measured and calculated doses were compared. To evaluate the dose calculations in heterogeneity for small fields SBRT treatment, similar plans were also generated and delivered on a heterogeneous thoracic phantom for 5 different size targets in the lung. Results: Dose comparisons between measurements and calculations showed 5.2%, 1.88%, 1.34%, 1.01% and 0.85% difference for SBRT plans with small central axis beams and 0.96%, 0.15%, 0.58%, 0.22% and 0.77% difference for plans with off-axis beams for five different size targets. For the thoracic phantom, the differences on dose between measurements and calculations are bigger, which are 8%, 5.9%, 4.5%, 3.9% and 4.5%, respectively. Conclusion: Dose verification for small fields used in the SBRT treatment has been performed based on ion-chamber measurements in both homogenous and heterogeneous phantoms. More than a 5% difference has been observed in the heterogeneous phantom, especially for very small fields. To meet the ICRU recommendation on a dose difference of no more than 5%, some corrections on the commissioning parameters of the TPS are needed.

60 APPLIED LIFE SCIENCES↗

SU-E-T-367: Evaluate the Dosimetric Impacts On Patient Specific Treatment Plans Due to Set Up Uncertainties During LINAC Annual QA and Commission

Purpose: To quantify the dosimetric impact on patient’s specific treatment plans due to set up uncertainties during LINAC commission and annual QA and to determine the maximum set up uncertainty allowance range. Methods: A 60×60×60 cm{sup 3} solid water cube was created in Varian Eclipse TPS. Beam data profiles (crossline and diagonal) and PDDs for field sizes ranging from 2×2 cm{sup 2} to 40×40 cm{sup 2} were simulated. Three main uncertainty scenarios were purposely introduced for gantry position tilts (0–5°), source axis distance changes (100–105 cm), and iso-center position shifts (0–5 mm) during the simulation. A gamma analysis was used to compare the correct simulated profiles with the profiles for each scenario. Two static IMRT treatment plans (H&N and GYN) with tumors at 5 cm and 15 cm depths were compared using similar set up uncertainties. Results: A gamma analysis using ±3%/±3mm with 90% passing rate criteria is included to show the passing rate for each scenario. Crossline and diagonal profiles showed a gamma passing rating of ≥ 90% at depth ≤10 cm for these scenarios: gantry tilted from 0–5°, SAD changed from 100–105 cm, and iso-center shifted ≤ 4 mm. From 10 to 20 cm depths, all three scenarios failed with gamma passing ≤ 90% excepted for diagonal profiles at Gantry =2°, SAD =1 cm, and iso-center =1 mm off center. Diagonal profiles showed a higher gamma passing rating compared to crossline profiles for all three scenarios. PDD differences also increased as depth increased. For patient’s specific treatment plans, maximum uncertainties allowed to obtain a ≥90% gamma passing rating are: gantry tilts ±1 degree, SAD shifts ±2 cm, and iso-center moves ±3 mm. Conclusion: This study validated AAPM TG 142 recommendations on the mechanical and dosimetry uncertainties and provided proofs on maximum acceptance tolerances for LINAC annual QA and commission.

60 APPLIED LIFE SCIENCES↗

SU-E-T-668: Radiosensitizing Effect of Bosutinib On Prostate and Colon Cancers: A Pilot in Vitro Study

Purpose: Recently it has been reported that Bosutinib, a clinical kinase inhibitor, can enhance the tumor cell chemosensitivity by overriding DNA damage checkpoints. However, to the best of our knowledge, there is no report on its effect on cell radiosensitivity in the literature. The objective of the present study is to determine whether Bosutinib has the potential to be used as a radiosensitizer for various cancer cell lines. Methods: In this study, we tested 4 cell lines derived from human prostate (LNCaP, PC-3, DU-145) and colon (HT-29) cancers. The cells were seeded into 12-well plates 24 hours prior to the radiation treatments. For each cell line, we designed 4 study groups, namely, the control, Bosutinib, radiotherapy, and radiotherapy+Bosutinib groups. We used 6 MV photon beams from a Siemens Artiste accelerator to deliver 2 Gy dose in one fraction to the cells in the radiotherapy and radiotherapy+Bosutinib groups. Immediately after irradiation, the cells in the radiotherapy+Bosutinib group were treated with Bosutinib (1µM) for 3 hours. The cell survival was evaluated through clonogenic assays. Results: The cell survival rates of the LNCaP, PC-3, DU-145, and HT-29 cells were found to be 21%, 92%, 76%, and 93% for the radiotherapy group; 21%, 69%, 67%, and 81% for the radiotherapy+Bosutinib group; and 103%, 107%, 86%, and 102% for the Bosutinib group, respectively. Although synergetic cell killing was not seen for the LNCaP and DU-145 cell lines in this study, the cell survival data from the clonogenic assay indicated that Bosutinib could enhance the sensitivity of PC-3 and HT-29 cells to radiation treatment. Conclusion: Our preliminary results demonstrated the possibility of Bosutinib as a radiosensitizer for certain prostate and colon cancers, which are resistant to radiotherapy. Further studies are warranted to quantify the radiosensitizing effect of Bosutinib.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-F-CAMPUS-J-02: Commissioning of Radiofrequency Tracking for Gated SBRT of the Liver Using Novel Motion System

Purpose: Tracking soft tissue targets has recently been approved as a new application of the Calypso radiofrequency tracking system allowing for gated treatment of the liver based on the motion of the target volume itself. As part of the commissioning process, an end-to-end test was performed using a 3D diode array and 6D motion platform to verify the dosimetric accuracy and establish the workflow of gated SBRT treatment of the liver using Calypso. Methods: A 4DCT scan of the ScandiDos Delta4 phantom was acquired using the HexaMotion motion platform to simulate realistic breathing motion. A VMAT plan was optimized on the end of inspiration phase of the 4DCT scan and delivered to the Delta4 phantom using the Varian TrueBeam. The treatment beam was gated by Calypso to deliver dose at the end of inspiration. The expected dose was compared to the delivered dose using gamma analysis. In addition, gating limits were investigated to determine how large the gating range can be while still maintaining dosimetric accuracy. Results: The 3%/3mm and 2%/2mm gamma pass rate for the gated treatment delivery was 100% and 98.4%, respectively. When increasing the gating limits beyond the known extent of planned motion from the 4DCT, the gamma pass rates decreased as expected. The 3%/3mm gamma pass rate for a 1, 2, and 3mm increase in gating limits were measured to be 96.0%, 92.7%, and 78.8%, respectively. Conclusion: Radiofrequency tracking was shown to be an effective way to provide gated SBRT treatment of the liver. Baseline gating limits should be determined by measuring the extent of target motion during the respiratory phases used for planning. We recommend adding 1mm to the baseline limits to provide the proper balance between treatment efficiency and dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

Visual exploration of high-dimensional data through subspace analysis and dynamic projections

Here, we introduce a novel interactive framework for visualizing and exploring high-dimensional datasets based on subspace analysis and dynamic projections. We assume the high-dimensional dataset can be represented by a mixture of low-dimensional linear subspaces with mixed dimensions, and provide a method to reliably estimate the intrinsic dimension and linear basis of each subspace extracted from the subspace clustering. Subsequently, we use these bases to define unique 2D linear projections as viewpoints from which to visualize the data. To understand the relationships among the different projections and to discover hidden patterns, we connect these projections through dynamic projections that create smooth animated transitions between pairs of projections. We introduce the view transition graph, which provides flexible navigation among these projections to facilitate an intuitive exploration. Finally, we provide detailed comparisons with related systems, and use real-world examples to demonstrate the novelty and usability of our proposed framework.

97 MATHEMATICS AND COMPUTING↗

TH-C-19A-08: PDD Discrepancies at Opposite Biases From Very Small Volume Ion Chambers When Using Water Scanners

Purpose: As more so-called micro ion chambers become commercially available, medical physicists may be inclined to use them during the linear accelerator commissioning process, in an attempt to better characterize the beam in steep dose gradient areas. The purpose of this work is to inform the medical physics community of a non-trivial, anomalous behavior observed when very small chambers are used in certain beam scanning configurations. Methods: A total of six ion chambers (0.007cc to 0.6cc) were used to scan PDDs from a 10×10cm2 field at both +300V and −300V biases. PDDs were scanned using three different water tank scanning systems to determine whether different scanners exhibit the same abnormality. Finally, PDDs were sampled using an external electrometer to bypass the internal electrometer of the scanner to determine the potential contributions of the scanner electronics to the abnormality observed. Results: We observed a reproducible, significant difference (over-response with depth) in PDDs acquired when using very small ion chambers with certain bias and watertank combinations, on the order of 3–5% at a depth of 25 cm in water. This difference was not observed when the PDDs were sampled using the ion chambers in conjunction with an external electrometer. This suggests a contribution of interference produced by the controller box and scanning system, which becomes significant for the very small signals collected by very small ion chambers, especially at depth, as the signal level is reduced even further. Conclusion: Based on the results observed here, if currently available very small ion chambers are used with specific bias and scanning water-tank combinations, erroneous PDD data may be collected. If this data is used as input to the Treatment Planning System, systematic errors on the order of 3%–5% may be introduced into the treatment planning process.

07 ISOTOPE AND RADIATION SOURCES↗

TH-C-19A-09: Quantification of Transmission and Backscatter Factors as a function of Distance to Inhomogeneity Interface for Three Types of Surgical Implant Plates

Purpose: Carbon fiber materials have been increasingly used clinically, mainly in orthopedics, as an alternative to metallic implants because of their minimal artifacts on CT and MRI images. This study characterizes the transmission and backscatter property of carbon fiber plates (CarboFix Orthopedics, Herzeliya, Israel) with measurements for radiation therapy applications, and compares them to traditional Stainless Steel (SS) and Titanium (Ti) metal materials. Methods: For the transmission measurements, 1-mm-thick test plate was placed upstream from a plane parallel Markus chamber, separated by various thicknesses of polystyrene plates in 0.5 cm increments between 0 and 5 cm. With this setup, we quantified the radiation transmission as a function of distance to the inhomogeneity interface. The LINAC source to detector distance was maintained at 100 cm and 200 MU was delivered for each measurement. Two 3-cm solid water phantoms were placed at the top and bottom to provide build up. All the measurements were performed for 6 MV and 18 MV photons. The backscatter measurements had the identical setup, except that the test plate was downstream of the chamber from radiation. Results: The carbon fiber plates did not introduce any measureable inhomogeneity effect on the transmission and backscatter factor because of its low atomic number. In contrast, traditional metal implant materials caused up to 15% dose difference at upstream and 25% backscatter at downstream from radiation. Such differences decrease as the distance to the inhomogeneity interface increases and become unmeasurable at distance of 3 cm and 1 cm for upstream and downstream, respectively. Conclusion: A new type of carbon fiber implant plate was evaluated and found to have minimal inhomogeneity effect in MV radiation beams. Patients would benefit from a carbon based implant over metal for radiation therapy due to their minimal backscatter and imaging artifacts.

60 APPLIED LIFE SCIENCES↗

SU-E-J-162: Quality Assurance Procedures for MR Guided Focused Ultrasound Treatment of Bone Metastasis

Purpose: The purpose of this work is to develop and verify our quality assurance (QA) procedures to ensure the safety and efficacy of MR-guided focused ultrasound (MRgFUS) treatment of bone metastases. Methods: A practical QA program was developed. Monthly and daily QA (DQA) procedures were performed. The major QA items included the checks of the machine hardware, software and patient safety features. Briefly, these checks/tests include: 1) the cooling system reservoir and treatment table; 2) power to the treatment table; 3) the MR coil; 4) the transducer position with MRI; 5) image display on the treatment work station; 6) the effective focal spot in 3 directions using MR thermometry; and 7) all the safety devices including a sonication lamp, and the emergency stop-sonication switches. In order to avoid patient skin burn, it is important to remove gas bubbles in the interfaces between the treatment table and the gel pad, and the gel pad and patients skin during the patient setup. Our QA procedures have been verified and evaluated through patient treatments. Seven patients with scapula, humeral head, sacrum, ilium, pubic ramus and acetabular bone metastases were treated using MRgFUS. Results: Our study showed that all seven patients tolerated the MRgFUS treatment well. No skin toxicity or other complications were observed. The pain score (0–10) using the visual analog scale (VAS) was significantly reduced from 8.0 ± 1.1 before treatment to 4.7 ± 3.0, 3.0 ± 1.5, 3.2 ± 2.8 and 3.4 ± 1.5 at one day, one month, two months and three months after the MRgFUS treatment, respectively. Conclusion: We demonstrated that with the appropriate QA procedures, MRgFUS is a safe, effective and noninvasive treatment modality for palliation of bone metastases.

60 APPLIED LIFE SCIENCES↗

SU-E-T-34: An in Vivo Study On Pulsed Low Dose-Rate Radiotherapy for Prostate Cancer

Purpose: Re-irradiation with conventional radiotherapy techniques (CRT) may pose significant risks due to high accumulative radiation doses. Pulsed low dose-rate radiotherapy (PLDR) has been used in clinical trials for recurrent cancer treatment. In our previous studies, PLDR irradiation showed significantly lower toxicity than CRT, resulting in much longer survival of mice after PLDR total body irradiation (TBI) than conventional TBI. The purpose of this study was to investigate tumor control efficacy of PLDR treatment for prostate cancer with an animal model of prostate cancer LNCaP. Methods: We used an orthotopic murine model of LNCaP cell line for this study. LNCaP cells were implanted into immune-suppressed male nude mice via surgery. We monitored the tumor growth with MRI. The tumor-bearing mice were allocated into a PLDR(n=9), CRT(n=7), and control group(n=7) randomly. The mice in the PLDR and CRT groups were irradiated with 2Gy dose for one time. For the CRT treatment, the mice received 2Gy at a dose-rate of 300 MU/minute. For the PLDR treatment, the 2Gy dose was further divided into ten pulses of 0.2Gy at the same dose-rate with an interval of 3 minutes between the pulses. Results: Sizable tumor growth delays were observed for the PLDR and CRT groups through weekly MRI scans. The mean values of the normalized tumor volumes (± standard deviation of the mean) were 1.53±0.07, 1.53±0.14, and 1.81±0.09 at one week after treatment, 2.28±0.13, 2.19±0.16, and 3.04±0.25 at two weeks after treatment, and 3.31±0.23, 3.14±0.24 and 4.62±0.49 at three weeks after treatment, for the PLDR, CRT, and control groups, respectively. Conclusion: The PLDR and CRT treatments showed comparable tumor control rates in this study. Our in vivo results indicate that PLDR may be a viable option for treating recurrent prostate cancer due to its equivalent tumor control but low normal tissue toxocities.

60 APPLIED LIFE SCIENCES↗

SU-E-T-409: Intensity Modulated Robotic Radiotherapy

Purpose: As compared with the IRIS-based models, the MLC-based CyberKnife system allows more efficient treatment delivery due to its improved coverage of large lesions and intensity modulation. The treatment delivery efficiency is mainly determined by the number of selected nodes. This study aimed to demonstrate that relatively small sets of optimally selected nodes could produce high-quality plans. Methods: The full body path of the CyberKnife system consists of 110 nodes, from which we selected various sets for 4 prostate cancer cases using our in-house beamselection software. With the selected nodes we generated IMRT plans using our in-house beamlet-based inverse-planning optimization program. We also produced IMRT plans using the MultiPlan treatment planning system (version 5.0) for the same cases. Furthermore, the nodes selected by MultiPlan were used to produce plans with our own optimization software so that we could compare the quality of the selected sets of nodes. Results: Our beam-selection program selected one node-set for each case, with the number of nodes ranging from 23 to 34. The IMRT plans based on the selected nodes and our in-house optimization program showed adequate target coverage, with favorable critical structure sparing for the cases investigated. Compared with the plans using the nodes selected by MultiPlan, the plans generated with our selected beams provided superior rectum/bladder sparing for 75% of the cases. The plans produced by MultiPlan with various numbers of nodes also suggested that the plan quality was not compromised significantly when the number of nodes was reduced. Conclusion: Our preliminary results showed that with beamletbased planning optimization, one could produce high-quality plans with an optimal set of nodes for MLC-based robotic radiotherapy. Furthermore, our beam-selection strategy could help further improve critical structure sparing.

60 APPLIED LIFE SCIENCES↗

SU-E-T-501: Normal Tissue Toxicities of Pulsed Low Dose Rate Radiotherapy and Conventional Radiotherapy: An in Vivo Total Body Irradiation Study

Purpose: Pulsed low dose rate radiotherapy (PLDR) is a re-irradiation technique for therapy of recurrent cancers. We have previously shown a significant difference in the weight and survival time between the mice treated with conventional radiotherapy (CRT) and PLDR using total body irradiation (TBI). The purpose of this study was to investigate the in vivo effects of PLDR on normal mouse tissues.Materials and Methods: Twenty two male BALB/c nude mice, 4 months of age, were randomly assigned into a PLDR group (n=10), a CRT group (n=10), and a non-irradiated control group (n=2). The Siemens Artiste accelerator with 6 MV photon beams was used. The mice received a total of 18Gy in 3 fractions with a 20day interval. The CRT group received the 6Gy dose continuously at a dose rate of 300 MU/min. The PLDR group was irradiated with 0.2Gyx20 pulses with a 3min interval between the pulses. The mice were weighed thrice weekly and sacrificed 2 weeks after the last treatment. Brain, heart, lung, liver, spleen, gastrointestinal, urinary and reproductive organs, and sternal bone marrow were removed, formalin-fixed, paraffin-embedded and stained with H and E. Morphological changes were observed under a microscope. Results: Histopathological examination revealed atrophy in several irradiated organs. The degree of atrophy was mild to moderate in the PLDR group, but severe in the CRT group. The most pronounced morphological abnormalities were in the immune and hematopoietic systems, namely spleen and bone marrow. Brain hemorrhage was seen in the CRT group, but not in the PLDR group. Conclusions: Our results showed that PLDR induced less toxicity in the normal mouse tissues than conventional radiotherapy for the same dose and regimen. Considering that PLDR produces equivalent tumor control as conventional radiotherapy, it would be a good modality for treatment of recurrent cancers.

60 APPLIED LIFE SCIENCES↗

A Hybrid Redox-Supercapacitor System with Anionic Catholyte and Cationic Anolyte

A significant challenge for energy storage technologies is to realize battery-level energy density and capacitor-level durability and power density in one device. By introducing an electrolyte composed of an anionic catholyte and a cationic anolyte into a symmetric carbon-based supercapacitor configuration, a hybrid electrochemical battery-supercapacitor system using soluble redox species delivers significantly improved energy density from 20 to 42 W.h/kg (based on the electrode mass) and stable capacities for > 10(4) cycles. The ionic species formed in the electrolyte are studied by UV-Vis, Raman and mass spectroscopy to probe the energy storage mechanism. The strategy is general and may provide a route to critically-needed fast-charging devices with both high energy density and power. (C) 2014 The Electrochemical Society. All rights reserved.

Wang, B↗

Facile synthesis of one-dimensional peapod-like Sb@C submicron-structures

We demonstrate a novel synthetic route to fabricate a one-dimensional peapod-like Sb@C structure with disperse Sb submicron-particles encapsulated in carbon submicron-tubes. The synthetic route may well serve as a general methodology for fabricating carbon/metallic fine structures by thermally reducing their carbon-coated metal oxide composites.

Luo, W↗

Carbon nanofibers derived from cellulose nanofibers as a long-life anode material for rechargeable sodium-ion batteries

A highly reversible anode is indispensable to the future success of sodium-ion batteries (SIBs). Herein, carbon nanofibers (CNFs) derived from cellulose nanofibers are investigated as an anode material for SIBs. The CNFs exhibit very promising electrochemical properties, including a high reversible capacity (255 mA h g(-1) at 40 mA g(-1)), good rate capability (85 mA h g(-1) at 2000 mA g(-1)), and excellent cycling stability (176 mA h g(-1) at 200 mA g(-1) over 600 cycles).

Luo, W↗