Engineering Papers⌕ Search

Engineering topics

Stoeckl, C.

Publications and source records attributed to Stoeckl, C..

At least 73 records · Page 4

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

Using millimeter-sized carbon-deuterium foils for high-precision deuterium-tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA laser facility. While the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils better characterized, and impact of uncontrolled foil motion prior to detection investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using millimeter-sized carbon–deuterium foils for high-precision deuterium–tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. Additionally, while the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels are low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.

47 OTHER INSTRUMENTATION↗

A novel photomultiplier tube neutron time-of-flight detector

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. At DT neutron yields larger than 1013 a novel detector consisting of a microchannel-plate photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signal in PMT nTOF is produced from neutron interaction with a PMT window. The direct interaction of neutrons with MCP has negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOFs were deployed on the OMEGA Laser System for the first time to diagnose inertial confinement fusion plasma. Here, the design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

47 OTHER INSTRUMENTATION↗

Optimization of a short-pulse-driven Si He-α soft x-ray backlighter

High backlighter brightness is important to maximize the number of detected photons in radiography experiments and to minimize the background while backlighting high-energy density plasmas with strong self-emission. Here, several different configurations were tested to improve the brightness of the Si He-α x-ray line emission at a photon energy of 1865 eV from high-energy (>1 kJ), short-pulse (~20-ps), laser-driven backlighter targets. The emission from low-density SiO 2 foam targets, the effects of a laser prepulse, and Si targets with a CH “shield” that form a small cavity were compared to solid-density, flat Si targets. The CH “shield” targets showed the best performance with a >5× improvement in time integrated emission and an x-ray pulse duration of ~25 ps with no measurable spectral shift of the Si He-α emission line. A conversion efficiency from laser light into Si He-α photons of the order of 1 × 10 –5 was inferred from the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Self-radiography of imploded shells on OMEGA based on additive-free multi-monochromatic continuum spectral analysis

Radiographs of pure-DT cryogenic imploding shells provide critical validation of progress toward ignition-scalable performance of inertial confinement fusion implosions. Cryogenic implosions on the OMEGA Laser System can be self-radiographed by their own core spectral emission near ≈2 keV. Utilizing the distinct spectral dependences of continuum emissivity and opacity, the projected optical-thickness distribution of imploded shells, i.e., the shell radiograph, can be distinguished from the structure of the core emission distribution in images.Importantly, this can be done without relying on spectral additives (shell dopants), as in previous applications of implosion self-radiography. Furthermore, demonstrations with simulated data show that this technique is remarkably well-suited to cryogenic implosions and can also be applied to self-radiography of imploded room-temperature CH shells at higher spectral energy (hv ≈ 3–5 keV) based on the very similar continuum spectrum of carbon. Experimental demonstration of additive-free self-radiography with warm CH shell implosions on OMEGA will provide an important proof of principle for future applications to cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraining physical models at gigabar pressures

High-energy-density (HED) experiments in convergent geometry are able to test physical models at pressures beyond hundreds of millions of atmospheres. The measurements from these experiments are generally highly integrated and require unique analysis techniques to procure quantitative infor mation. This work describes a methodology to constrain the physics in convergent HED experiments by adapting the methods common to many other fields of physics. As an example, a mechanical model of an imploding shell is constrained by data from a thin-shelled direct-drive exploding-pusher experiment on the OMEGA Laser System using Bayesian inference, resulting in the reconstruction of the shell dynamics and energy transfer during the implosion. The model is tested by analyzing synthetic data from a 1-D hydrodynamics code and is sampled using a Markov chain Monte Carlo to generate the posterior distributions of the model parameters. As a result, the goal of this work is to demonstrate a general methodology that can be used to draw conclusions from a wide variety of HED experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy Flow in Thin Shell Implosions and Explosions

Energy flow and balance in convergent systems beyond petapascal energy densities controls the fate of late-stage stars and the potential for controlling thermonuclear inertial fusion ignition. Time-resolved x-ray self-emission imaging combined with a Bayesian inference analysis is used to describe the energy flow and the potential information stored in the rebounding spherical shock at 0.22 PPa (2.2 Gbar or billions of atmospheres pressure). This analysis, together with a simple mechanical model, describes the trajectory of the shell and the time history of the pressure at the fuel-shell interface, ablation pressure, and energy partitioning including kinetic energy of the shell and internal energy of the fuel. Here, the techniques used here provide a fully self-consistent uncertainty analysis of integrated implosion data, a thermodynamic-path independent measurement of pressure in the petapascal range, and can be used to deduce the energy ow in a wide variety of implosion systems to petapascal energy densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of spatiotemporal smoothing on the two-plasmon–decay instability

Higher levels of hot electrons from the two-plasmon–decay instability are observed when smoothing by spectral dispersion (SSD) is turned off in directly driven inertial confinement fusion experiments at the Omega Laser Facility. This finding is explained using a hot-spot model based on speckle statistics and simulation results from the laser–plasma simulation environment. The model accurately reproduces the relative increase in hot-electron activity at two different drive intensities, although it slightly overestimates the absolute number of hot electrons in all cases. Extrapolating from the current ≈ 360-GHz system while adhering to the logic of the hot-spot model suggests that larger SSD bandwidth should significantly mitigate hot-electron generation, and legacy 1-THz OMEGA experiments appear to support this conclusion. These results demonstrate that it is essential to account for laser speckles and spatiotemporal smoothing to obtain quantitative agreement with experiments. A compilation of hot-electron data from the past two decades reveals several other important points: (1) many prior experiments are more easily understood using recent results from multibeam absolute instability theory; and (2) experiments with ignition-scale conditions produce less hot electrons compared to OMEGA spherical experiments for a given vacuum overlapped intensity, which is a promising result for validating performance predictions based on hydrodynamic scaling relations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D xRAGE simulation of inertial confinement fusion implosion with imposed mode 2 laser drive asymmetry

Low-mode asymmetries represent an important obstacle to achieving high-gain inertial confinement fusion implosions. As a step in learning how to control such effects, an OMEGA experiment with imposed mode 2 laser drive asymmetries was done to study the expected signatures of this type of asymmetry [M. Gatu Johnson et al., PRE 2018]. In the present work, a 3D xRAGE simulation including the stalk mount has been brought to bear on the data from that experiment. Furthermore, comprehensive comparisons between simulated and measured observables are made. Good agreement between simulated and measured x-ray image-inferred shell trajectories, bang times and neutron emission widths are seen, showing that the hydrodynamics are well captured in the simulation. Asymmetries seen in simulated and measured time-resolved and time-integrated x-ray images and areal densities also compare well, showing impact of both stalk and mode 2. On the other hand, important differences in measured and simulated neutron emission histories, yield, and ion temperature (T ion ) asymmetries are seen, suggesting that the simulation is overestimating shock yield. Overall, the results clearly demonstrate the importance of considering all asymmetry sources when interpreting measured signatures of asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hot-electron generation at direct-drive ignition-relevant plasma conditions at the National Ignition Facility

Laser–plasma interaction instabilities can be detrimental for direct-drive inertial confinement fusion by generating high-energy electrons that preheat the target. Moreover, an experimental platform has been developed and fielded on the National Ignition Facility to investigate hot-electron production from laser–plasma instabilities at direct-drive ignition-relevant conditions. The radiation-hydrodynamic code DRACO has been used to design planar-target experiments that generate plasma and interaction conditions comparable to direct-drive ignition designs: I L ~10 15 W/cm 2 , T e > 3 keV, and density-gradient scale lengths of L n ~ 600 μ m in the quarter-critical density region. The hot-electron properties were inferred by comparing the experimentally observed hard x-ray spectra to Monte Carlo simulations of hard x-ray emission from hot electrons depositing energy in the target. Hot-electron temperatures of ~40 keV to 60 keV and the fraction of laser energy converted to hot electrons of ~0.5% to 5% were inferred in plastic targets for laser intensities at the quarter-critical density surface of (~4 to 14) × 10 14 W/cm 2 . The use of silicon ablators was found to mitigate the hot-electron preheat by increasing the threshold laser intensity for hot-electron generation from ~3.5 × 10 14 W/cm 2 in plastic to ~6 × 10 14 W/cm 2 in silicon. The overall hot-electron production is further reduced in silicon ablators when the intensity threshold is exceeded.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anomalous Absorption by the Two-Plasmon Decay Instability

Radiation-hydrodynamic simulations of directly driven fusion experiments at the Omega Laser Facility predict absorption accurately when targets are driven at low overlapped laser intensity. Discrepancies appear at increased intensity, however, with higher-than-expected laser absorption on target. Strong correlations with signatures of the two-plasmon decay (TPD) instability—including half-harmonic and hard-x-ray emission—indicate that TPD is responsible for this anomalous absorption. Scattered light data suggest that up to ≈ 30 % of the laser power reaching quarter-critical density can be absorbed locally when the TPD threshold is exceeded. A scaling of absorption versus TPD threshold parameter was empirically determined and validated using the laser–plasma simulation environment code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A suite of neutron time-of-flight detectors to measure hot-spot motion in direct-drive inertial confinement fusion experiments on OMEGA

A suite of six neutron time of flight detectors capable of measuring the primary DT neutron energy spectrum has recently been completed on the OMEGA Laser System. The detectors are positioned along multiple quasi-orthogonal lines of sight (LOS’s) in either a stand-alone, collinear, or antipodal configuration. The collinear detector configuration enables one to measure the neutron velocity along the detector LOS independent of the neutron-production history, while the antipodal detector configuration enables one to directly measure of the hot-spot velocity along the detector axis and Gamow velocity shift due to the plasma ion temperature. Using these six measurements of the primary DT neutron energy spectrum, the neutron-averaged hot-spot velocity and Gamow velocity shift of DT fusion neutrons have been measured in cryogenic experiments on OMEGA for the first time. Finally, the detector suite is operable between DT neutron yields of 1 × 10 13 to 2 × 10 14 with an uncertainty of ~14 km/s in the neutron-averaged hot-spot velocity measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of stalk on directly driven inertial confinement fusion implosions

Low-mode asymmetries have emerged as one of the primary challenges to achieving high-performing inertial confinement fusion (ICF) implosions. In direct-drive ICF, an important potential seed of such asymmetries is the capsule stalk mount, the impact of which has remained a contentious question. In this paper, we describe the results from an experiment on the OMEGA laser with intentional offsets at varying angles to the capsule stalk mount, which clearly demonstrates the impact of the stalk mount on implosion dynamics. The angle between stalk and offset is found to significantly impact observables. Specifically, a larger directional flow is observed in neutron spectrum measurements when the offset is toward rather than away from the stalk, while an offset at 42° to the stalk gives minimal directional flow but still generates a large flow field in the implosion. No significant directional flow is seen due to stalk only. Time-integrated x-ray images support these flow observations. A trend is also seen in implosion yield, with lower yield obtained for offsets with a smaller angle than with a larger angle toward the stalk. Radiation hydrodynamic simulations using 2D DRACO and 2D/3D Chimera not including the stalk mount and using 2D xRAGE including the stalk mount are brought to bear on the data. The yield trend, the minimal directional flow with stalk only, and the larger flow enhancement observed with the offset toward the stalk are all reproduced in the xRAGE simulations. Finally, the results strongly indicate that the stalk impact must be considered and mitigated to achieve high-performing implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of laser-driven magnetic fields with a continuous wave Faraday rotation diagnostic

Magnetic fields driven by a laser in coil targets were studied for laser energies of ~25 J and two pulse durations of 2.8 ns and 70 ps. Axial magnetic fields in the coils were measured by continuous wave Faraday rotation diagnostics. The diagnostics indicated magnetic fields of 6–14 T in the coil and currents of 10–20 kA. Magnetic fields were compared for similar laser targets, focusing conditions, and laser energies. A 30-times increase in the intensity of the laser beam by reducing the pulse duration resulted in an increase in the magnetic field and current by a factor of 2. The relaxation time of the magnetic pulse was on the sub-microsecond scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of a Talbot–Lau x-ray deflectometer diagnostic platform for the OMEGA EP laser

A Talbot–Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >10 22 cm -3 by means of Moiré deflectometry. The experiment used a short-pulse laser (30–100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described. Finally, the necessary modifications to accurately probe the ablation front through TXD using the EP-TXD diagnostic platform are discussed.

36 MATERIALS SCIENCE↗

Inferred UV fluence focal-spot profiles from soft x-ray pinhole-camera measurements on OMEGA

A method was developed with laser-irradiated Au planar foils to characterize the focal spot of UV laser beams on target at full energy from soft x-ray emission. A pinhole camera with a back-thinned charge-coupled–device detector and filtration with thin Be and Al foil filters provides images of the x-ray emission at photon energies <2 keV. This method requires a careful measurement of the relation between the applied UV fluence and the x-ray signal, which can be described by a power-law dependence. The measured exponent γ ~ 2 provides a dynamic range of ~25 for the inferred UV fluence. UV fluence profiles of selected beams were measured for 100-ps and 1-ns laser pulses and were compared to directly measured profiles from an UV equivalent-target-plane diagnostic. The inferred spot size and super-Gaussian order from the x-ray technique agree within several percent with the values measured with the direct UV measurements.

47 OTHER INSTRUMENTATION↗