Engineering PapersSearch

Engineering topics

Steinberg, R.

Publications and source records attributed to Steinberg, R..

31 records · Page 2

An X-ray monitor for measurement of a titanium tritide target thickness.

An X-ray device capable of measuring titanium tritide film thickness from 0.1 to 30 microns has been built and tested. The monitor was designed for use in a rotating target system which used thick targets and incorporated a sputtering electrode to remove depleted layers from the target surface. The thickness measurement can be done in the presence of an intense background of bremsstrahlung and characteristic titanium X-radiation. A measurement can be accomplished in situ in two hours with reasonable accuracy.

Alger, D. L.

Access to uncombined titanium through an inhibiting film in sublimation pumping of deuterium.

In principle, titanium bulk sublimator pumping should be ideal for removing large quantities of deuterium from a vacuum system. In practice, much of the deposited titanium remains uncombined and is wasted. We have demonstrated, through a series of experiments, that it is possible (by the addition of a thin layer of titanium to an apparently occluded surface) to gain access to previously deposited sublayers of uncombined titanium in spite of the presence of an inhibiting film (such as an oxide) on the surface.

Steinberg, R.

An X-ray monitor for measurement of a titanium tritide target thickness

An X-ray device capable of measuring titanium tritide film thickness from 0.1 to 30 micrometers has been built and tested. The monitor was designed for use in a rotating target system which used thick targets and incorporated a sputtering electrode to remove depleted layers from the target surface. The thickness measurement can be done in the presence of an intense background of bremsstrahlung and characteristic titanium X-radiation. A measurement can be accomplished in situ in two hours with reasonable accuracy.

Alger, D. L.

A high yield neutron target for cancer therapy

A rotating target was developed that has the potential for providing an initial yield of 10 to the 13th power neutrons per second by the T(d,n)He-4 reaction, and a useable lifetime in excess of 600 hours. This yield and lifetime are indicated for a 300 Kv and 30 mA deuteron accelerator and a 30 microns thick titanium tritide film formed of the stoichiometric compound TiT2. The potential for extended lifetime is made possible by incorporating a sputtering electrode that permits use of titanium tritide thicknesses much greater than the deuteron range. The electrode is used to remove in situ depleted titanium layers to expose fresh tritide beneath. The utilization of the rotating target as a source of fast neutrons for cancer therapy is discussed.

Alger, D. L.