Smits, R. G.

Publications and source records attributed to Smits, R. G..

Correction of atmospheric distortion with an image-sharpening telescope

A 30 x 5 cm aperture telescope employing six movable mirrors to compensate for atmospherically induced phase distortion is built and tested. A feedback system adjusts the mirrors in real time to maximize the intensity of light passing through a narrow slit in the image plane. Essentially diffraction-limited performance is achieved when imaging both laser and white-light objects through 250 m of turbulent atmosphere. The behavior of the telescope is accurately predicted by computer simulations. The system has yet to achieve its full potential, but has already operated successfully for objects as dim as 5th magnitude.

Buffington, A.

Active image restoration with a flexible mirror

The 30 by 5 cm aperture telescope described uses six moveable mirrors to compensate for phase distortions induced by the atmosphere. A feedback system is used to adjust the mirrors in real time to maximize the intensity of light passing through a narrow slit in the image plane. Using the telescope, diffraction-limited images of objects were obtained, using both laser and white light, through 250 meters of turbulent atmosphere.

Buffington, A.

A liquid xenon radioisotope camera.

A new type of gamma-ray camera is discussed that makes use of electron avalanches in liquid xenon and is currently under development. It is shown that such a radioisotope camera promises many advantages over any other existing gamma-ray cameras. Spatial resolution better than 1 mm and counting rates higher than one million C/sec are possible. An energy resolution of 11% FWHM has recently been achieved with a collimated Hg-203 source using a parallel-plate ionization chamber containing a Frisch grid.

Zaklad, H.

A large granite stage and measuring microscope.

A stage and measuring microscope servocontrolled by a computer have been constructed. The travel of the stage is 0.5 x 0.5 m and the travel of the microscope objective is 7.5 cm. The measuring accuracy is 1 micron in the x-y plane and 5 microns along the z axis. The mechanical and optical construction of the stage and microscope, as well as the way in which the control electronics are organized, permit great flexibility of operation. Possible applications include the scanning and measuring of astronomical plates, the laying out of patterns of semiconductor devices of very large sizes, and the measurement of precision grids.

Alston-Garnjost, M.

Liquid-filled proportional counter

Liquid Xe filled single wire proportional and multiple wire ionization chambers, measuring gain and time/spatial resolution properties

Alvarez, L. W.