Engineering PapersSearch

Engineering topics

Simon, F. F.

Publications and source records attributed to Simon, F. F..

At least 37 records · Page 2

Status of the NASA-Lewis flat-plate collector tests with a solar simulator

Simulator test results of 15 collector types are reported. Collectors are given performance ratings according to their use for pool heating, hot water, absorption A/C or heating and solar Rankine machines. Collectors found to be good performers in the above categories, except for pool heating, were a black nickel coated, 2 glass collector, and a black paint 2 glass collector containing a mylar honeycomb. For pool heating, a black paint, one glass collector was found to be the best performer. Collector performance parameters of 5 collector types were determined to aid in explaining the factors that govern performance. The two factors that had the greatest effect on collector performance were the collector heat loss and the coating absorptivity.

Simon, F. F.

Flat-plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program is described which includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented. The collector performance obtained with the solar simulator will be correlated with data obtained by conducting tests outdoors at Lewis.

Vernon, R. W.

Flat plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program being conducted at Lewis will provide the basis for selecting collectors for use at Langley. The technology program includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented herein.

Vernon, R. W.

Status of the NASA-Lewis flat-plate collector tests with a solar simulator

Simulator test results of 15 collector types are presented. Collectors are given performance ratings according to their use for pool heating, hot water, absorption A/C or heating, and solar Rankine machines. Collectors found to be good performers in the above categories, except for pool heating, were a black nickel coated, 2 glass collector, and a black paint 2 glass collector containing a mylar honeycomb. For pool heating, a black paint, one glass collector was found to be the best performer. Collector performance parameters of 5 collector types were determined to aid in explaining the factors that govern performance. The two factors that had the greatest effect on collector performance were the collector heat loss and the coating absorptivity.

Simon, F. F.

Flat-plate collector performance evaluation. The case for a solar simulation approach

A method is proposed for determining the performance of flat-plate solar collector using a simulated sun. Collector test variables that will help establish the basis for the indoor test facility at the Lewis Research Center are discussed. The use of the indoor testing should permit a standard test for the convenient and accurate determination of collector performance. Preliminary test results are reported as an example of the type of collector performance data to be expected from the simulation approach.

Simon, F. F.

Effect of contact angle hysteresis on moving liquid film integrity.

A study was made of the formation and breakdown of a water film moving over solid surfaces (teflon, lucite, stainless steel, and copper). The flow rate associated with film formation was found to be higher than the flow rate at which film breakdown occurred. The difference in the flow rates for film formation and film breakdown was attributed to contact angle hysteresis. Analysis and experiment, which are in good agreement, indicated that film formation and film breakdown are functions of the advancing and receding angles, respectively.

Simon, F. F.

Effect of contact angle hysteresis on moving liquid film integrity

A study was made of the formation and breakdown of a water film moving over solid surfaces (teflon, lucite, stainless steel, and copper). The flow rate associated with film formation was found to be higher than the flow rate at which film breakdown occurred. The difference in the flow rates for film formation and film breakdown was attributed to contact angle hysteresis. Analysis and experiment, which are in good agreement, indicated that film formation and film breakdown are functions of the advancing and receding angles, respectively.

Simon, F. F.