Mach Number Effects on Turbine Blade Transition Length Prediction

The effect of a Mach number correction on a model for predicting the length of transition was investigated. The transition length decreases as the turbulent spot production rate increases. Much of the data for predicting the spot production rate comes from low speed flow experiments. Recent data and analysis showed that the spot production rate is affected by Mach number. The degree of agreement between analysis and data for turbine blade heat transfer without film cooling is strongly dependent of accurately predicting the length of transition. Consequently, turbine blade heat transfer data sets were used to validate a transition length turbulence model. A method for modifying models for the length of transition to account for Mach number effects is presented. The modification was made to two transition length models. The modified models were incorporated into the two-dimensional Navier-Stokes code, RVCQ3D. Comparisons were made between predicted and measured midspan surface heat transfer for stator and rotor turbine blades. The results showed that accounting for Mach number effects significantly improved the agreement with the experimental data.

Boyle, R. J.

Flow visualization study of the effect of injection hole geometry on an inclined jet in crossflow

A flow visualization was studied by using neutrally buoyant, helium-filled soap bubbles, to determine the effect of injection hole geometry on the trajectory of an air jet in a crossflow and to investigate the mechanisms involved in jet deflection. Experimental variables were the blowing rate, and the injection hole geometry cusp facing upstream (CUS), cusp facing downstream (CDS), round, swirl passage, and oblong. It is indicated that jet deflection is governed by both the pressure drag forces and the entrainment of free-stream fluid into the jet flow. For injection hole geometries with similar cross-sectional areas and similar mass flow rates, the jet configuration with the larger aspect ratio experienced a greater deflection. Entrainment arises from lateral shearing forces on the sides of the jet, which set up a dual vortex motion within the jet and thereby cause some of the main-stream fluid momentum to be swept into the jet flow. This additional momentum forces the jet nearer the surface. Of the jet configurations, the oblong, CDS, and CUS configutations exhibited the largest deflections. The results correlate well with film cooling effectiveness data, which suggests a need to determine the jet exit configuration of optimum aspect ratio to provide maximum film cooling effectiveness.

Simon, F. F.

Comparison of photovoltaic cell temperatures in modules operating with exposed and enclosed back surfaces

Four different photovoltaic module designs were tested to determine the cell temperature of each design. The cell temperatures were compared to those obtained on identical design, using the same nominal operating cell temperature (NOCT) concept. The results showed that the NOCT procedure does not apply to the enclosed configurations due to continuous transient conditions. The enclosed modules had higher cell temperatures than the open modules, and insulated modules higher than the uninsulated. The severest performance loss - when translated from cell temperatures - 17.5 % for one enclosed, insulated module as a compared to that module mounted openly.

Namkoong, D.

Spectral effects on direct-insolation absorptance of five collector coatings

Absorptances for direct insolation of black chrome, black nickel, copper oxide, and two black zinc conversion selective coatings were calculated for a number of typical solar spectrums. Measured spectral reflectances were used while the effects of atmospheric ozone density, turbidity, and air mass were incorporated in calculated direct solar spectrums. Absorptance variation for direct insolation was found to be of the order of 1 percent for a typical range of clear-sky atmospheric conditions.

Hotchkiss, G. B.

A method for correlating performance data of a terrestrial solar cell array

An analytical method was proposed for characterizing array power output, in the region of maximum power, as a function of environmental variables. The correlation provided a way of evaluating the output of an array under environmental conditions that differ from those encountered during testing. Power data obtained at one location was used to predict array performance at other locations.

Simon, F. F.

A mobile apparatus for solar collector testing

The design, construction, and operation of a mobile apparatus for solar collector testing (MASCOT) is described. The MASCOT is a self-contained test unit costing about $10,000 whose only external requirement for operation is electrical power and which is capable of testing two water-cooled flat-plate solar collectors simultaneously. The MASCOT is small enough and light enough to be transported to any geographical site for outdoor tests at the location of collector usage. It has been used in both indoor solar simulator tests and outdoor tests.

Hotchkiss, G. B.

An experimental investigation with artificial sunlight of a solar hot-water heater

Thermal performance measurements were made of a commercial solar hot water heater in a solar simulator to determine basic performance characteristics of a traditional type of flat plate collector, with and without side reflectors (to increase the solar flux). Information on each of the following was obtained; (1) the effect of flow and incidence angle on the efficiency of a flat plate collector (but only without side reflectors); (2) transient performance under flow and nonflow conditions; (3) the effectiveness of reflectors to increase collector efficiency for a zero radiation angle at fluid temperatures required for solar air conditioning; and (4) the limits of applicability of a collector efficiency correlation based on the Hottel Whillier equation.

Simon, F. F.

Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented in this report. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

Johnson, S. M.

An experimental investigation with artificial sunlight of a solar hot-water heater

Thermal performance measurements were made of a commercial solar hot-water heater in a solar simulator. The objective of the test was to determine basic performance characteristics of a traditional type of flat-plate collector, with and without side reflectors (to increase the solar flux). Due to the fact that collector testing in the solar simulator permits control of the variables that affect collector performance, it was possible to obtain information on each of the following: (1) the effect of flow and incidence angle on the efficiency of a flat-plate collector (but only without side reflectors), (2) transient performance under flow and nonflow conditions, (3) the effectiveness of reflectors in increasing collector efficiency for a zero radiation angle at fluid temperatures required for solar air conditioning, and (4) the limits of applicability of a collector efficiency correlation based on the Hottel-Whillier equation (1958).

Simon, F. F.

Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

Johnson, S. M.

A generalized correlation of experimental flat-plate collector performance

A generalized correlation of flat-plate collector performance obtained by outdoor and indoor test methods is presented. This correlation shows that the indoor (simulator) test approach is a special case of the general situation of variable solar conditions. The important feature of the generalized correlation is that it permits a separation of the solar variables (flux, incident angle, etc.) which affect collector performance from the collector parameters (absorptance, transmittance, heat loss, etc.) which also affect collector performance and which are uniquely part of a given collector design. The correlation permits an evaluation of the relative merits of using instantaneous, hourly and daily collector efficiencies in obtaining a good collector correlation. The question of the transient behavior outdoors of a collector is an important part of determining whether to use instantaneous, hourly or daily efficiency values in a correlation approach. Correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs, (2) collector performance prediction under conditions that differ from the conditions of the test program, and (3) monitoring performance degradation effects.

Simon, F. F.

Flat-plate solar-collector performance evaluation with a solar simulator as a basis for collector selection and performance prediction

This paper reports the measured thermal efficiency and evaluation of 23 collectors which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, anti-reflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors are given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance is made possible by tests at different incident angles. The solar performance rankings are made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.

Comparison under a simulated sun of two black-nickel-coated flat-plate solar collectors with a nonselective black-paint-coated collector

A performance evaluation was made of two, black nickel coated, flat plate solar collectors. Collector performance was determined under a simulated sun for a wide range of inlet temperatures, including the temperature required for solar powered absorption air conditioning. For a basis of comparison a performance test was made on a traditional, two glass, nonselective, black paint coated, flat plate collector. Performance curves and performance parameters are presented to point out the importance of the design variables which determine an efficient collector. A black nickel coated collector was found to be a good performer at the conditions expected for solar powered absorption air conditioning. This collector attained a thermal efficiency of 50 percent at an inlet temperature of 366 K (200 F) and an incident flux of 946 watts/sq m (300 Btu/hr-sq ft).

Simon, F. F.

Outdoor flat-plate collector performance prediction from solar simulator test data

Solar collector performance data obtained from tests with a simulator was modified for real-life conditions. The data obtained with the simulator was corrected for the variable conditions of ambient temperature, wind, incident angle, flow rate, etc., that are encountered outdoors. Modification of simulator data was accomplished by combining experiment with theory. The technique was demonstrated by application to a spectrally selective and a nonselective type of collector. This kind of modified simulator collector performance data should be valuable in solar systems analysis and for collector performance ranking based on all-day calculated conditions.

Simon, F. F.

Outdoor flat-plate collector performance prediction from solar simulator test data

This paper describes how collector performance obtained from test data with a simulator can be modified for real-life conditions. The approach taken is to correct the performance data obtained with the simulator for the variable conditions of ambient temperature, wind, incident angle, flow rate, etc., that are encountered in outdoor conditions. Modification of simulator data is accomplished by combining experiment with theory. The technique is demonstrated by application to a spectrally selective and a nonselective type of collector. This kind of modified simulator collector performance data should be valuable in solar systems analyses and for collector performance ranking based on all-day calculated conditions.

Simon, F. F.

Flat-Plate Solar-Collector Performance Evaluation with a Solar Simulator as a Basis for Collector Selection and Performance Prediction

The use of a solar simulator for performance determination permits collector testing under standard conditions of wind, ambient temperature, flow rate and sun. The performance results determined with the simulator have been found to be in good agreement with outdoor performance results. The measured thermal efficiency and evaluation of 23 collectors are reported which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, antireflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors were given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance was made possible by tests at different incident angles. The solar performance rankings were made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.

A generalized correlation of experimental flat-plate collector performance

A generalized collector performance correlation was derived and shown by experimental verification to be of the proper form to account for the majority of the variable conditions encountered both in outdoor and in indoor collector tests. This correlation permits a determination of collector parameters which are essentially nonvarying under conditions which do vary randomly (outdoors) or conditions which vary in a controlled manner (indoors - simulator). It was shown that correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs; (2) collector performance prediction under conditions that differ from the conditions of the test program; and (3) monitoring performance degradation effects.

Simon, F. F.