Airtightness of Commercial Building Envelopes: Where are we and where could we go?

Air leakage in commercial buildings accounts for about one quad of energy annually; therefore, efforts have been put in place to decrease this energy penalty. Data from blower door tests indicate that the airtightness of new building envelopes has been improving in certain niches because of requirements set by local governments and the US Army Corps of Engineers (USACE), as well as the availability of air barrier consultants. Advances in air barrier technologies and construction practices have also contributed to these improvements. Even with these promising results, efforts have been slow to revise building codes so that they establish a maximum air leakage rate requirement for new buildings and envelope retrofits. This paper summarizes current techniques used to conduct whole building air leakage tests, where these tests are mandatory, how the air leakage rate of buildings appears to be decreasing, and what stakeholders think about blower door tests. The paper also includes the nationwide source energy and financial savings potential for standalone retail buildings that were calculated using a newly developed simulation tool that more accurately estimates the effect of air leakage on energy use.

Hun, Diana E.↗

Creating a Virtual Utility District: Assessing Quality and Building Energy Impacts of Microclimate Simulations

Buildings in China, India, the United States (US), and United Kingdom (UK) consume 39-45% of each nation's primary energy with fast-growing countries like India projected to use 76% of their primary energy by 2040. In the United States, 73% of all electricity is consumed by buildings. In an effort to better operate electrical grids, needs exist to generate improved load models by better understanding and quantifying weather impacts and microclimate effects on building-specific energy use throughout a city.Scalable methods have been created to allow urban-scale energy modeling – to identify and synthesize a fully-articulated building energy model for every building in an area of interest. This was applied to the 1,385 km2 utility district serviced by the Electric Power Board of Chattanooga, TN. Each building is simulated on the world’s 4th-fastest supercomputer, Titan, using the U.S. Dept. of Energy’s flagship whole-building simulation tool, EnergyPlus, to analyze relationships among climatic conditions, urban morphology, land cover, and energy use. The Weather Research Forecast (WRF) model was scaled on several High Performance Computing (HPC) resources to simulate microclimate variation under different urban morphologies. We analyze the differences between WRF-based microclimate simulations and measured weather station data. This information is then used to quantify impact of microclimate variation and variable-specific meteorological variables on the electrical consumption for individual buildings and show impacts at the scale of a utility district.

New, Joshua↗

Model-based optimizations of packaged rooftop air conditioners using low global warming potential refrigerants

Based on laboratory investigations for R-22 and R-410A alternative low GWP refrigerants in two baseline rooftop air conditioners (RTU), the DOE/ORNL Heat Pump Design Model was used to model the two RTUs and the models were calibrated against the experimental data. We compared the compressor efficiencies and heat exchanger performances. An efficiency-based compressor mapping method was developed. Extensive model-based optimizations were conducted to provide a fair comparison between all the low GWP candidates by selecting optimal configurations. The results illustrate that all the R-22 low GWP refrigerants will lead to slightly lower COPs. ARM-20B appears to be the best R-22 replacement at normal conditions. At higher ambient temperatures, ARM-20A exhibits better performance. All R-410A low GWP candidates will result in similar or better efficiencies than R-410A. R-32 has the best COP while requiring the smallest compressor. Finally, R-452B uses the closest compressor displacement volume and achieves the same efficiency as R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model validations for low-global warming potential refrigerants in mini-split air-conditioning units

To identify low GWP (global warming potential) refrigerants to replace R-22 and R-410A, extensive experimental evaluations were conducted for multiple candidates of refrigerant at the standard test conditions and at high-ambient conditions with outdoor temperature varying from 27.8 C to 55.0 C.. In the study, R-22 was compared to propane (R-290), DR-3, ARM-20B, N-20B and R-444B in a mini-split air conditioning unit originally designed for R-22; R-410A was compared to R-32, DR-55, ARM-71A, L41-2 (R-447A) in a mini-split unit designed for R-410A. To reveal physics behind the measured performance results, thermodynamic properties of the alternative refrigerants were analysed. In addition, the experimental data was used to calibrate a physics-based equipment model, i.e. ORNL Heat Pump Design Model (HPDM). The calibrated model translated the experimental results to key calculated parameters, i.e. compressor efficiencies, refrigerant side two-phase heat transfer coefficients, corresponding to each refrigerant. As a result, these calculated values provide scientific insights on the performance of the alternative refrigerants and are useful for other applications beyond mini-split air conditioning units.

54 ENVIRONMENTAL SCIENCES↗

A Comparison of Simulation Capabilities for Ducts

Typically, the cheapest way to install a central air conditioning system in residential buildings is to place the ductwork in the attic. Energy losses due to duct-attic interactions can be great, but current whole-house models are unable to capture the dynamic multi-mode physics of the interactions. The building industry is notoriously fragmented and unable to devote adequate research resources to solve this problem. Builders are going to continue to put ducts in the attic because floor space is too expensive to closet them within living space, and there are both construction and aesthetic issues with other approaches such as dropped ceilings. Thus, there is a substantial need to publicly document duct losses and the cost of energy used by ducts in attics so that practitioners, builders, homeowners and state and federal code officials can make informed decisions leading to changes in new construction and additional retrofit actions. Thus, the goal of this study is to conduct a comparison of AtticSim and EnergyPlus simulation algorithms to identify specific features for potential inclusion in EnergyPlus that would allow higher-fidelity modeling of HVAC operation and duct transport of conditioned air. It is anticipated that the resulting analysis from these simulation tools will inform energy decisions relating to the role of ducts in future building energy codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Test Report #33: Compressor Calorimeter Test of R-410A Alternative: R-32/R-134a Mixture Using a Scroll Compressor

This report investigates the tested performance of lower - GWP candidate refrigerant, 94.07 wt% R - 32 + 5.93 wt % R - 134 a mixture (hereafter referred to as R - 32/134a), as an alternative to baseline refrigerant R - 410 A using a 36,000 Btu/hr compressor calorimeter located at the Heat Exchanger Advanced Testing Facility at Oak Ridge National Laboratory . These tests were conducted during May and August 2013. R - 410A is a near - azeotropic blend of R - 32 and R - 125 with 0.5/0.5 mass fraction and has a GWP 100 of 2100. R - 32 and R - 134a are pure refrigerants and have GWP 100 of 716 and 1370 1, respectively. Based on the GWP 100 values of pure refrigerants and their mass fraction in the blend, GWP 100 of R - 32/134a, which is under development by National Refrigerant, is 755. This report compares various performance parameters, such as cooling capacity, compressor power, refrigerant mass flow rate, EER, isentropic efficiency and discharge temperature of the alternative refrigerant to that of R - 410 A.