Engineering Papers⌕ Search

Engineering topics

Shrestha, Som

Publications and source records attributed to Shrestha, Som.

At least 55 records · Page 3

Climate benefits and building energy efficiency gains from improved roofing insulation in cold climates

The high thermal resistivity of polyisocyanurate insulation is attributed to its closed cell structure that is filled with low-thermal-conductivity blowing agent vapor. However, existing polyisocyanurate products exhibit a decrease in their thermal-resistance values at lower temperatures due to the condensation of the blowing agent vapor. Because use of insulation with higher thermal resistivity can lead to improved energy efficiency of commercial buildings, which results in lower operational greenhouse gas emissions, there is a clear need to address this reduced performance at lower temperatures through product innovation.

54 ENVIRONMENTAL SCIENCES↗

Fabrication of New PCM Hydrogel Composites

Salt hydrates are low-cost phase-change materials (PCMs) with excellent thermal energy storage capacities. However, they are limited by low thermal cycling stability due to incongruent melting-induced phase separation. This project will solve the long-standing issue of phase separation of salt hydrates by stabilizing salt particles in a charged polymer hydrogel network. The proposed approach uses combined physical and chemical stabilization mechanisms achieved by selecting a proper chemistry and molecular weight of the polymer matrix. In summary, we have identified several important formulations that show good energy storage capacity performance and good cycling stability. The thermal storage capacity can be further improved through further sample optimization. The thermal conductivities of the samples were low, but there are ways to improve it by adding a highly thermally conductive material with a high aspect ratio. The method of preparation is suitable for scale-up.

25 ENERGY STORAGE↗

Molecular dynamics simulations of energy accommodation between gases and polymers for ultra-low thermal conductivity insulation

Determining the energy accommodation between gases and solids is essential to developing porous thermal insulation materials with ultra-low effective thermal conductivity that reduce energy use, greenhouse gas emissions, and fossil fuel consumption. The energy accommodation coefficients of most gases, however, have been rarely studied, especially with respect to solids that have relatively high thermal resistivity, e.g., polymers. Here, by using all-atom nonequilibrium molecular dynamics simulations, we reveal the accommodation coefficients of He, Ar, N 2 , and O 2 with polymers, mainly polystyrene. We find that their values are around 0.51, 0.72, 0.79, and 0.90, respectively, suggesting a critical reexamination of the commonly used theoretical maximum value of 1. We have also conducted experiments and validated the value for air, which is about 0.81. Such a change in accommodation coefficients can lead to a reduction of about 70%, 50%, 35%, and 20% in the thermal conductivity of He, Ar, N 2 , and O 2 gases in nano pores (below 100 nm) or at low pressures (below 1 millibar). With these new accommodation coefficients, we find that in a 10 nm pore with ambient pressure at 300 K, the gas thermal conductivity of He, Ar, N 2 , and O 2 in porous polystyrene can be as low as 9.7 × 10 –4 , 3.4 × 10 –4 , 7.3 × 10 –4 , and 8.5 × 10 –4 W·m –1 ·K –1 , respectively, which are two to three orders of magnitude lower than their bulk values, promising higher thermal resistivity of insulation materials. This work reveals the fundamental energy exchange between gases and polymers, providing important guidance for designing high-performance thermal insulation materials for various applications.

36 MATERIALS SCIENCE↗

Conduction Heat Transfer through Solid in Porous Materials: A Comparative Study by Finite-Element Simulations and Effective Medium Approximations

The development of insulation materials with low effective thermal conductivity is essential for energy savings in various applications, including buildings, food services, pipe insulation, and refrigeration. Such materials can be developed by using micro- or nanoporous structures, as well as low-thermal conductivity gases and/or reduced pressure. A variety of effective medium approximation (EMA) models have been developed to study thermal transport through solid in porous structures. However, in many cases, the impacts of porosity on solid conduction are not well predicted by EMA models because of the assumptions made for simplification. Furthermore, the results can vary by a factor of up to 1.5, depending on the morphology of the pores. Hence, proper guidance is needed to choose the appropriate EMA model for a given morphology. This work presents a finite element method study using COMSOL Multiphysics software for various geometries, including hollow cubes, overlapping hollow spheres (normally stacked and tightly packed), and Voronoi structures, and compares the results to those obtained from various EMA models. Simulation results for the hollow cubes and Voronoi structures matched well with the Maxwell-Eucken and Russell model. The results for hollow spheres closely matched the Bauer model and the Glicksman model with fitting parameters. This work provides guidance on analyzing and designing insulation materials for energy savings in the future.

36 MATERIALS SCIENCE↗

Smart and Efficient Building Envelopes: Thermal Switches and Thermal Storage for Energy Savings and Load Flexibility

The building envelope has traditionally been seen as a static component. Much of the past thermal advancements in building envelopes has consisted of developing higher R/inch insulation. While a suitable approach for static situations, it does not consider the dynamic nature of the ambient environment or the varying needs of the electrical grid. This paper will examine three possible ways that building envelopes can be actively managed: 1. thermal switches, 2. thermal storage, and 3. the coupling of the two. Spurring innovation to make building envelopes smarter will help reduce building energy consumption and peak energy usage and contribute to flexibility in energy demand in the future.

Mumme, Sven↗

Evaluation of measuring thermal conductivity of isotropic and anisotropic thermally insulating materials by transient plane source (Hot Disk) technique

The transient plane source (TPS) technique, also referred as the Hot Disk method, has been widely used due to its ability to measure the thermal properties of an extensive range of materials (solids, liquids, and powder). Recently, it has been recognized that typical Hot Disk sensors can influence TPS results of thermally insulating materials and lead to an overestimation of thermal conductivity. Although improvements have been proposed, they have not yet been implemented in the commercial TPS, leaving researchers with non-standardized modifications or options provided by a commercial Hot Disk apparatus. An empirical study of thermally insulating materials such as extruded polystyrene (XPS) and aerogel blanket is conducted in order to address the factors that affect the reliability of thermal conductivity k obtained using the commercial TPS apparatus. Sensor size, input power, duration of the measurements, applied pressure, and, in the case of anisotropic materials, heat capacity are investigated, and the results are compared with those using a Heat Flow Meter apparatus. The effect of sensor size on the k value is ascribed to heat loss through connecting leads and is more pronounced in smaller sensors and in materials with lower k values . In the case of XPS and aerogel, the effect becomes minimal for sensors with a radius r ≥ 6.4 mm. The low input power yields a high scattering of the results and should be avoided. Applied contact pressure and the tested region of the specimen play an important role in experiments with low-density fibrous materials due to the large percentage of heat being transferred by radiation and the heterogeneous nature of the samples, respectively. Additionally, the sensitivity of anisotropic measurements to the value of the material’s volumetric heat capacity ( ρC p ) is shown, emphasizing the need for the precise determination.

thermal conductivity↗

Unification of nonequilibrium molecular dynamics and the mode-resolved phonon Boltzmann equation for thermal transport simulations

Nano-size confinement induces many intriguing non-Fourier heat conduction phenomena, such as nonlinear temperature gradients, temperature jumps near the contacts, and size-dependent thermal conductivity. Over the past decades, these effects have been studied and interpreted by nonequilibrium molecular dynamics (NEMD) and phonon Boltzmann transport equation (BTE) simulations separately, but no theory that unifies these two methods has ever been established. In this work, we unify these methods using a quantitative mode-level comparison and demonstrate that they are equivalent for various thermostats. We show that different thermostats result in different non-Fourier thermal transport characteristics due to the different mode-level phonon excitations inside the thermostats, which explains the different size-dependent thermal conductivities calculated using different reservoirs, even though they give the same bulk thermal conductivity. Specifically, the Langevin thermostat behaves like a thermalizing boundary in phonon BTE and provides mode-level thermal-equilibrium phonon outlets, while the Nose-Hoover chain thermostat and velocity rescaling method behave like biased reservoirs, which provide a spatially uniform heat generation and mode-level nonequilibrium phonon outlets. These findings explain why different experimental measurement methods can yield different size-dependent thermal conductivity. They also indicate that the thermal conductivity of materials can be tuned for various applications by specifically designing thermostats. Finally, the unification of NEMD and phonon BTE will largely facilitate the study of thermal transport in complex systems in the future by, e.g., replacing computationally unaffordable first-principles NEMD simulations with computationally less expensive spectral BTE simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermally Anisotropic Composites for Heat Redirection and Thermal Management in Building Envelopes

In building envelope systems, thermal management is important from energy conservation and thermal comfort perspectives, and is typically done via insulation, thermal mass, solar control and shading, etc. Thermal anisotropy is commonly utilized in electronics for heat dissipation. This article investigates the feasibility of utilizing thermally anisotropic composites (TACs) to reduce unwanted heat gains and losses through the building envelope by redirecting the heat transfer to or from appropriate heat sinks and sources.Numerical simulations of building envelope components using COMSOL Multiphysics and whole building simulations using EnergyPlus (E+) were performed to estimate the energy savings potential of TACs used in external walls of residential buildings. Application of TACs was compared with baseline walls with cavity insulation as well as with and without exterior continuous insulation (CI). The COMSOL simulations indicated 75% or higher reductions in heat gains when using a TAC coupled with a heat sink compared to an exterior CI case. In terms of energy savings in a hot climate, E+ models estimated cooling energy savings of 19% with a "TAC + heat sink" compared to a baseline wall with only cavity insulation. Further, a small-scale test sample with a TAC-heat sink system was built and tested in a multi-transducer heat flow meter (HFM). The heat sink was a copper tube circulating cold water. The experiments verified the re-direction of heat to a sink and significant reduction in heat transfer through the test specimen. The experiments showed that the heat redirection only occurred in the presence of both thermal anisotropy and water circulation; if either element was missing, the system behaved like a traditional envelope component.

Biswas, Kaushik↗

Review of Models to Evaluate and Guide the Development of Low-Thermal-Conductivity Materials

Developing insulation materials with low–thermal conductivity values is appealing for building envelope retrofits and new construction. Therefore, it is a priority research area for the US Department of Energy Building Technologies Office (BTO). Multiple institutions are exploring various methods to develop new insulation materials with a thermal resistivity ≥97 m·K/W (14 h·ft2·°F/Btu/inch). Current materials that provide such high thermal resistivity use micro- or nanoporous structures, as well as low–thermal conductivity gases and reduced pressure. Efforts to develop these new materials would benefit greatly from a tool that can numerically evaluate various options to optimize material design and achieve the desired thermal resistivity. The available models do not capture all modes of heat transfer through the complex structures required to achieve very high thermal resistivity. This paper presents a literature review of the existing models that have been used in the study of heat transfer mechanisms of insulation materials such as aerogels, foams, and fibrous materials. The review shows most of the models make some assumptions to simplify the analysis. Further, such models have not included important factors, such as the size effect and the interfacial effect, which could significantly affect heat transfer through insulation materials. Moreover, there is a lack of a database for the thermal accommodation coefficients of various insulation materials that are used to calculate gaseous thermal conductivity. In addition, this paper presents details regarding the development of new models. The new models will capture various factors that have been neglected in existing models (such as nanoscale heat transfer, interfacial thermal resistance). They will allow parametric studies that identify optimum design options for insulation materials and thus accelerate the achievement of BTO’s goal of developing insulation technologies with thermal resistivity greater than ≥97 m·K/W (14 h·ft2·°F/Btu/inch).

Shrestha, Som↗

Moisture Transfer in Commercial Buildings Due to Air Leakage: A New Feature in the Online Airtightness Savings Calculator

Air leakage through the building envelopes is responsible for a large amount of energy use. The US Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies states that, in 2010, air infiltration was responsible for 20% of primary energy consumption attributable to the fenestration and building envelopes of commercial buildings. Despite this fact, improving airtightness is not always recognized by commercial building owners, as they have been slow in acknowledging and diminishing the detrimental effects of air leakage on energy use, comfort, indoor air quality, and building material durability.The design and construction industry would benefit from a credible, easy-to-use tool that estimates potential energy and financial savings in a standardized manner so designers and contractors can give building owners compelling reasons to invest in reducing air leakage. In 2016–2017, Oak Ridge National Laboratory, the National Institute of Standards and Technology, the Air Barrier Association of America, and the US-China Clean Energy Research Center for Building Energy Efficiency collaborated to develop an online calculator. This user-friendly calculator is free to the public and uses the simulation results of the whole building energy simulation tool EnergyPlus and the airflow simulation tool CONTAM. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. Four more commercial building types were also added to the existing database of three building types as part of this update. This paper describes the procedure used to calculate moisture transfer due to air leakage and provides examples that demonstrate the moisture transfer for each of the seven commercial building types that are currently part of the calculator.

Shrestha, Som↗

NIST Infiltration Tools for Commercial Buildings

The Department of Energy estimates that infiltration through building envelopes accounted for 6 % of the total energy consumed by commercial buildings and 21 % of the heating and cooling energy. Air barrier requirements are now being included in ASHRAE Standards 90.1 and 189.1 and other construction requirements. The energy impacts of unintended infiltration on building energy use can be significant, but current energy simulation software and design methods are generally not able to accurately account for envelope infiltration and the impacts of improved airtightness. NIST has been developing tools to better account for infiltration in building energy models. The tools that will be discussed in this paper include: CONTAM Results Export Tool; weather-correlated infiltration inputs for prototype commercial buildings and the associated Open Studio Measures; and a web-based tool to evaluate the energy savings of building envelope airtightening, which was developed with the Oak Ridge National Laboratory and the Air Barrier Association of America. This paper briefly describes each tool, their applications, and the benefits of using each. All of the tools are publicly available at no cost.

Ng, Lisa↗

Evacuated Spheres for Closed-Cell Vacuum Insulation

Insulation materials with a thermal resistance per inch higher than 6h∙ft 2 ∙°F/Btu∙in or R6/in (42m∙K/W) are needed for building envelope retrofits in which solutions with slim profiles are required because of minimal available space or because real estate has a premium cost. These insulation materials will also be of benefit to prefabricated construction given that slim designs either reduce shipping costs or increase the floor space provided to the customer. Vacuum insulation panels (VIPs) are the current state-of-the-art insulation material with a resistance of about R35/in (243m∙K/W); however, their use in buildings is hindered by the fact that damages to their protective film decrease their performance to ≤R8/in (56m∙K/W). Given the lack of robust, highly-insulating materials, we are exploring methods to develop evacuated spheres that can act as a closed-cell vacuum insulation. The evacuated spheres could be assembled into boards that could attain ~R14/in (97m∙K/W). Advantages that evacuated spheres will offer over VIPs are that they will likely be more suitable for construction because punctures will only cause localized damage, and that the boards could be cut into customized shapes. We are currently investigating two processes to evacuate spheres to produce polymeric vacuum insulation spheres (PVISs) and coated and evacuated insulation spheres (CEISs). PVISs involve the extrusion of economical polymers, blowing agents, and gas barriers. CEISs use naturally-occurring or synthesized hollow particles with porous shells that are evacuated and coated with a gas impermeable thin film. Both manufacturing processes aim for very large throughputs to ensure cost-effectiveness and adoption by the construction industry. This paper discusses the manufacturing techniques that we are exploring and our progress to date.

Hun, Diana E.↗

Energy Savings Impacts of Airtightness in U.S. Commercial Buildings

Air leakage in commercial buildings in the U.S. accounts for about one quad of energy annually. As the thermal resistance of commercial building envelopes continues to improve, the relative contribution of air leakage to heating and cooling loads is increasing. Several manufacturers have developed advance air barrier technologies and construction practices to reduce the air leakage in buildings. To help in the market penetration of these advance technologies, advances in easy to use tools for determining the impact of air leakage are needed. Oak Ridge National Laboratory (ORNL), the Air Barrier Association of America, the National Institute of Standards and Technology, and the US-China Clean Energy Research Center for Building Energy Efficiency partnered to develop an online calculator that estimates the potential energy and cost savings in major US, Canadian, and Chinese cities from improvements in airtightness. The calculator estimates the energy and cost savings potential based on the pre and post retrofit air leakage rates for prototype commercial buildings. This report explores extending these savings to determine the national level energy savings potential based on the weightage of commercial building type in different ASHRAE climate zone locations. The base infiltration rate of 1.07 CFM/ft2 was assumed for these calculations and the savings were calculated for three different air infiltration target rates of 0.4 CFM/ft2, 0.25 CFM/ft2, and 0.06 CFM/ft2. The national source energy savings of 238, 283, and 313 TBtu respectively were estimated for these target air infiltration rates.

Bhandari, Mahabir↗

Use of Hygrothermal Models for Understanding Water Transport in Corrosion Under Insulation Applications

Thermal insulation is used in operating facilities to conserve heat and protect against freezing amongst others. A consequence of insulating the equipment is the necessity to manage the introduced threat of corrosion under insulation (CUI). For CUI to occur, water and oxygen must enter and migrate through the insulation to reach the external surface of the equipment. The water transport characteristics are dependent on several factors such as type of insulation, type of jacketing, equipment operating temperature, external weather, water entry/leakage rate and cyclic service. In hot piping, there are competing water transport characteristics, as in water vapor moves outwards away from the equipment as water enters insulation. Knowing the water transport and the parameters that influence the time of wetness at the metal surface helps in understanding conditions favoring CUI.The use of transient hygrothermal models for moisture control is well established in the building insulation design codes and standards. The building designs naturally shed the liquid water to minimize entry and facilitate vapor management so that moisture doesn’t accumulate within building. Several building industry hygrothermal models have been developed and are available for commercial use. One such commercial model has been used to understand water transport in a CUI application. The case study involves evaluation of piping and equipment installed with a closed cell polyurethane insulation. The hygrothermal model provided insights on the parameters influencing the time of wetness and the ease of water escaping the equipment-insulation-jacketing system.

Venkateswaran, Sai P.↗

Improved Performance of Polyurethane Foam Insulation Using Ingeo Biopolymer Liners and its Impact on Energy Efficiency of Refrigerator and Freezers

This paper compares the effect of isothermal aging of the thermal conductivity of polyurethane foam in simulated refrigerator-freezer panels made from polylactic acid biopolymer from NatureWorks (IngeoTM) and high-impact polystyrene. Specimens were aged at room temperature and thermal conductivity measurements were made at 10°C over a period of 2.4 years. The energy use over the life of refrigerator-freezer is also calculated using the Energy-Efficient Refrigerator Analysis program which was developed by the United States Department of Energy to estimate the energy savings potential of various technology option upgrades (cabinet and refrigeration system) for rulemaking purposes. The results show that energy savings from implementing the Ingeo liner range from 818 to 1395 kWh (7 to 13% of total energy use) over a 15-year period.

Hossieny, Nemat↗