Performance of vortex generators in a Mach 2.5 low-bleed full scale 45-percent-internal-contraction axisymmetric inlet

Steady-state and dynamic flow characteristics associated with two sets of vortex generators having different mixing criteria were determined. The inlet performance with and without these vortex generators is presented. The vortex generators were successful in eliminating separation, increasing area-weighted total pressure recovery, and decreasing distortion. Transmission times obtained from cross-correlations of the wall static pressures and the diffuser exit total pressure showed no effect of the upstream flow characteristics on the diffuser exit pressures when generators were used. Without generators, separation occurred and the upstream pressure characteristics had immediate effects on the diffuser exit pressure characteristics.

Neumann, H. E.↗

Design of a very-low-bleed Mach 2.5 mixed-compression inlet with 45 percent internal contraction

A full-scale, mixed-compression inlet was designed for operation with the TF30-P-3 turbofan engine and tested at Mach numbers of 2.5 and 2.0. The two-cone axisymmetric inlet had minimum internal contraction consistent with high total pressure recovery and low cowl drag. At Mach 2.5, inlet recovery was 0.906 with only 0.021 centerbody bleed mass-flow ratio and no cowl bleed. Increased centerbody bleed gave a maximum inlet unstart angle of attack of 6.85 deg. At Mach 2.0, inlet recovery was 0.94 with only 0.014 centerbody bleed mass-flow ratio and no cowl bleed. Inlet performance and angle-of-attack tolerance is presented for operation at Mach numbers of 2.5 and 2.0.

Wasserbauer, J. F.↗

Distortion in a full-scale bicone inlet with internal focused compression and 45 percent internal contraction

The distortion characteristics were investigated at the subsonic diffuser exit of a full-scale, Mach 2.5, axisymmetric, mixed compression inlet. Performance and steady-state distortion characteristics were obtained at zero and maximum angle of attack and during an inlet unstart-restart sequence. For the configuration with no cowl bleed, steady-state distortion P(max)P(min)P(bar) ranged from 0.10 for critical inlet operation at 0 deg angle-of-attack to 0.306 for supercritical inlet operation at 6.84 deg angle-of-attack. Vortex generators provided a 50 percent reduction in steady-state distortion for critical operation. Bleed has a smaller effect on steady-stated distortion.

Wasserbauer, J. F.↗

Throat stability-by pass systems to increase the stable airflow range of a Mach 2.5 inlet with 60-percent internal contraction

The results of an experimental investigation to increase the stable airflow range (without unstart) of a supersonic mixed-compression inlet are presented. Various stability bypass entrances were located on the cowl side of the inlet throat. The types of entrance were distributed porous (normal holes), forward-slanted slot, and distributed educated slots. A large stable airflow range was obtained for each entrance type if a constant pressure was maintained in the stability bypass plenum. The distributed porous entrance provided the largest stable airflow range. Inlet unstart angle of attack was unaffected by the entrances.

Mitchell, G. A.↗

Distributed educated throat stability bypass to increase the stable airflow range of a Mach 2.5 inlet with 60-percent internal contraction

The results of an experimental investigation to increase the stable airflow operating range of a supersonic mixed-compression inlet are presented. A distributed educated throat stability-bypass entrance configuration was tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of about 16.1 percent was obtained if a constant pressure was maintained in the bypass plenum. Limited unstart angle of attack data are presented.

Shaw, R. J.↗

Forward slanted slot throat stability bypass to increase the stable airflow range of a Mach 2.5 inlet with 60 percent internal contraction

The results of an experimental investigation to increase the stable airflow operating range of a supersonic mixed-compression inlet are presented. Two forward-slanted slot stability-bypass entrance configurations were tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of 18.5 percent was obtained with the superior configuration if a constant pressure was maintained in the bypass plenum. Limited unstart angle-of-attack data are presented.

Shaw, R. J.↗

Distributed porous throat stability bypass to increase the stable airflow range of a Mach 2.5 inlet with 60 percent internal contraction

The results of an experimental investigation to increase the stable airflow operating range of a supersonic, mixed-compression inlet with 60-percent internal contraction are presented. Various distributed-porous, throat stability-bypass entrance configurations were tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of about 25 percent was obtained with the optimum configuration if a constant pressure was maintained in the by-pass plenum. The location of the centerbody bleed region had a decided effect on the overall inlet performance. Limited unstart angle-of-attack data are presented.

Shaw, R. J.↗

Minimizing boundary layer bleed for a mixed compression inlet

An experimental investigation of a full scale mixed compression inlet sized for the TF30-P-3 turbofan engine was conducted at Mach 2.5 and 2.0 operating conditions. The two cone axisymmetric inlet had minimum internal contraction consistent with high total pressure recovery and low cowl drag. At Mach 2.5, inlet recovery exceeded 0.90 with only 0.02 centerbody bleed mass-flow ratio and zero cowl bleed. A centerbody bleed of approximately 0.05 gave a maximum inlet unstart angle-of-attack of 6.85 deg. Inlet performance and angle-of-attack tolerance is presented for operation at Mach 2.5 and 2.0.

Wasserbauer, J. F.↗

Minimizing boundary layer bleed for a mixed compression inlet

An experimental investigation of a full scale mixed compression inlet sized for the TF30-P-3 turbofan engine was conducted at Mach 2.5 and 2.0 operating conditions. The two cone axisymmetric inlet had minimum internal contraction consistent with high total pressure recovery and low cowl drag. At Mach 2.5, inlet recovery exceeded 0.90 with only 0.02 centerbody bleed mass-flow ratio and zero cowl bleed. A centerbody bleed of approximately 0.05 gave a maximum inlet unstart angle-of-attack of 6.85 deg. Inlet performance and angle-of-attack tolerance is presented for operation at Mach 2.5 and 2.0.