Engineering PapersSearch

Engineering topics

Pohm, A. V.

Publications and source records attributed to Pohm, A. V..

Memory implications of the spin-value effect in soft multilayers

New multilayer permalloy materials with thin separation layers that have significantly increased M-R coefficients at room temperature have the potential for substantially increasing both the speed and density of M-R memories. An analysis in the following discussion shows that the bit density at a given performance level is related to the product of M-R response and sheet resistivity when operating at the current-density limit. With a doubling of both sheet resistivity and M-R response over existing materials, the bit area can be reduced by about a factor of 4. Alternatively, if the bit area is kept the same, signal output is increased by a factor of 4 and circuit time constants can be reduced by a factor of 16.

Pohm, A. V.

Demagnetization effects on forward and reverse thresholds of M-R memory elements

A refinement in the way hard-axis demagnetizing effects are treated in multilayer M-R memory elements brings experimental and calculated results into agreement for both the forward and reverse switching thresholds. In the improved model, the nonuniform rotation of the magnetization in the elements because of edge pinning is taken into account. The demagnetizing fields are treated as corrections to the hard-axis word field rather than an addition to the anisotropy constant.

Pohm, A. V.

Magnetometer with a miniature transducer and automatic scanning

The magnetometer is based on the time variation of the magnetic permeability in the magnetic material of its transducer; however, its operation is substantially different from the ordinary flux-gate magnetometer. The transducer uses 0.05 mm diameter plated magnetic wire and is made flat enabling it to make measurements of transverse magnetic fields as close as 0.08 mm from the surface, and it has very good spatial resolution because of its small active region of approximately 0.64 mm by 0.76 mm. The magnetometer uses an inexpensive clip-on millimeter for driving and processing the electrical signals and readout. It also utilizes an automatic scanning technique which is made possible by a specially designed transducer holding mechanism that replaces the ink pen on an X-Y recorder.

Debnam, W. J. J.

Magnetometer with miniature transducer and automatic transducer scanning apparatus

Magnetometer is simple to operate and has fast response. Transducer is rugged and flat and can measure magnetic fields as close as 0.08 mm from any relatively flat surface. Magnetometer has active region of approximately 0.64 by 0.76 mm and is capable of good spatial resolution of magnetic fields as low as 0.02 Oe (1.6 A/m).

Breckenridge, R. A.