Engineering Papers⌕ Search

Engineering topics

Perry, Kirsten

Publications and source records attributed to Perry, Kirsten.

25 records · Page 2

Unsupervised Azimuth Estimation of Solar Arrays in Low-Resolution Satellite Imagery through Semantic Segmentation and Hough Transform

This paper explains the use of a convolutional neural network (CNN) to segment solar panels in a satellite image containing solar arrays, and extract associated metadata from the arrays. A novel unsupervised technique is introduced to estimate the azimuth of each individual solar panel from the predicted mask of the convolutional neural network. This pipeline was developed with the aim of extracting necessary metadata for a solar installation, using only a set of latitude–longitude coordinates. Azimuth prediction results for 669 individual solar installations associated with 387 sites located across the United States are provided. A mean average error and median average error of 21.65 degrees and 1.0 degrees were obtained, respectively, when predicting the azimuth of the solar fleet data set, with about 80% of the results within an error of zero degrees of the ground truth azimuth value and about 85% within an error of 25 degrees. The predicted azimuth was then used to estimate the energy conversion of the solar arrays. Results show a 90.9 and 90.6 R-squared value for estimating alternating current (AC) and direct current (DC) energy, respectively, and a mean absolute percentage error (MAPE) of 1.70% in estimating the alternating current (AC) energy using the fully automated algorithm.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative: Performance Index-Based Analysis

In this analysis, we report on 250 PV systems throughout the US, comprising 157 MWdc of system capacity and over 10,000 monthly PI values based on high-frequency (subhourly) energy data and satellite-based resource data. The distribution of PI values is analyzed, and multiple causes of underperformance are assessed, including first-year startup issues, snowfall and inverter downtime. An initial distribution of raw monthly PI values was collected with mean measured / modeled performance of PI = 0.935. After correcting for the three identifiable loss factors mentioned above, an average monthly performance of PI = 0.994 was obtained, with a distribution closely following a Gumbel Extreme Value distribution. In particular, inverter availability was found to contribute a system energy loss of 2.3% on average, except in the first six months of operation when availability losses are closer to 8%. Other startup issues beyond inverter downtime such as partial string outage contributed an additional 5% underperformance in the first year of operation across the fleet. Winter performance was also found to be 5%-10% below summer performance on average, likely due to snowfall. A simple linear relationship was found between snow loss and monthly snowfall accumulation in cm, indicating between 6% - 40% loss in months with nonzero snowfall, depending on climate.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative Program and Methodology

The US Department of Energy’s PV Fleet Performance Data Initiative has been launched in order to collect and evaluate production data across multiple PV fleet partners. Performance statistics are anonymized, aggregated and shared to represent a snapshot of the US commercial and utility-scale fleet. Production data have been collected from over 1500 systems representing more than 1.3 GWdc capacity. Preliminary analysis indicates median performance loss rates are in line with previous publications of system degradation, on the order of –0.6%/yr to –0.9%/yr (preliminary numbers subject to change). These values are higher than module-only degradation rates which are often used in pro-forma estimates of project performance and economics, potentially exposing owner/operators to increased risk if systems under-perform over time.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Panel-Segmentation [SWR-21-18]

Panel-Segmentation contains the scripts for automated metadata extraction of solar PV installations, using satellite imagery coupled with computer vision techniques. In this package, the user can perform the following actions: *Automatically generate a satellite image using a set of lat-long coordinates, and a Google Maps API key. Users would need to set up a Google Cloud account and get a Maps Static API key. Please refer to Setting Up Google Maps Static API Key section for this process. *Perform image segmentation on the satellite image, to locate the solar array(s) in the image on a pixel-by-pixel basis, using an image segmentation model (panel_detection_model.pth). Get classification of the installation (rooftop, ground mounted fixed-tilt or tracking, carport, etc). *Perform azimuth estimation on each solar array cluster in the masked image. *Detect solar panels and get its latitude, longitude, and address within a geographic bounding box through the SOL-Searcher Pipeline. *Detect and calculate hurricane damage on solar installations given pre-hurricane and post-hurricane satellite imagery through the Hurricane Detection Pipeline. *Detect and calculate hail damage on solar installations given satellite imagery through the Hail Detection pipeline. *Convert NOAA MESH (Maximum Estimated Size of Hail) grib2 files into kml or geojson files. *Estimate tilt and azimuth of a solar array by processing USGS LiDAR data for the array’s location.

Edun, Ayobami↗

PV Fleet Performance Data Initiative (March 2020 Methodology Report)

Data for thousands of systems by multiple sources were transmitted to NREL for evaluation. Initial automated data quality assurance (QA) checks identified hundreds of systems (QA Tier 1) with high-quality meteorological and AC production data and hundreds of QA Tier 2 systems with adequate data quality. A standard RdTools analysis was conducted for these systems, evaluating performance loss on an annualized basis. To date with the systems evaluated so far, we find a median performance loss rate (aka Rd or degradation rates) for the entire fleet of -0.72%/year based on individual inverter data, which is in line with historical degradation rates previously published for modules and systems (-0.5% to -0.9% / yr, Jordan et al. 2016). A fleet-scale distribution based on revenue-grade meter data rather than inverter AC (alternating current) data yields a slightly different result. We are working to understand the difference between this result and the inverter-based result of -0.72%/year.

14 SOLAR ENERGY↗

RdTools™ [SWR-17-40]

RdTools™ provides a set of tools for quantifying the degradation of photovoltaic systems and modules.

Deceglie, Michael↗