Engineering Papers⌕ Search

Engineering topics

Perry, Kirsten

Publications and source records attributed to Perry, Kirsten.

At least 19 records

Availability and Performance Loss Factors for U.S. PV Fleet Systems

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data and publish aggregated, anonymized results. This report is an update of our previous publications, specifically a FY 2021 performance index publication and a FY 2022 fleet degradation analysis. In this analysis, we have increased our data participants and system totals by around 10% to 8.5 GW and 24,000 separate inverter data channels. Four major analysis topics are considered in this report: Performance Index (PI) trends, PV system availability, soiling losses, and PV system degradation. Performance Index and inverter availability are assessed on a larger set of data from our FY 2021 report: 1,128 systems compared with 200 systems from before. The increased number of systems is due to an improved data quality methodology, as well as introducing new systems to the analysis. Overall results are similar to previously published values - overall inverter availability is low in the first six months of system performance before reaching steady-state by the end of the first year. Excluding this six-month startup period, system-level aggregated data shows a median (P50) system availability of 0.99 and a lower 10th percentile (P90) value of 0.95 (Figure ES-1). A dependence on system size is also demonstrated, with worse inverter availability results for larger PV systems. Causes of this effect are under investigation, but may be impacted by inverter size, which also show lower availability for larger inverter sizes. This report also investigates PI, correcting for degradation, soiling, snow, and availability. Following these corrections, the median system PI over its entire lifetime is 0.95. PI values reported here are approximately 3% lower than what we presented in our previous FY 2021 report. Soiling loss is assessed in a comprehensive way for the first time in this report. Results are presented using the COmbined Degradation and Soiling (CODS) method, as implemented in RdTools (v3.0.0a4). Soiling values are presented for 255 systems, which indicated irradiance-weighted soiling loss greater than 1%. The values have been published in an updated NREL soiling map at nrel.gov/pv/soiling.html. Finally, we investigated system degradation using three different data analysis techniques: conventional RdTools (year-on-year (YOY)), CODS, and Performance Loss Rate (PLR) analysis. Overall degradation results are consistent with our previous publications. Rerunning conventional RdTools on our updated fleet shows that some data partners have systematically fallen below the median system degradation rate (change over time) of -0.75 %/year. A comparison with PLR analysis, which looks at change in annual PI over time, shows that median system degradation is consistent with -0.5% to -0.75% per year change. However, at the P90 value, system degradation is substantially faster. These two results are consistent and indicate that resulting degradation statistics depend to a great degree on the population of PV systems making up the analysis cohort and whether soiling impacts the systems. The use of CODS for degradation analysis provides a different method for degradation assessment, which explicitly excludes the impact of recoverable soiling on degradation analysis. Excluding soiling effects yields an annual system degradation around -0.5% per year on average. This indicates that a portion of system performance loss may be attributed to periodic soiling that is not fully recovered. This report provides PV system owners/operators with background and methods to analyze PV system performance, give guidance for expected cohort performance, and performance loss values for use in pro-forma financial models, which guide new-build system design and bankability reports.

14 SOLAR ENERGY↗

PV System Availability from Commercial and Utility-Scale Systems [Slides]

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with worse inverter availability results for larger PV systems. Potential causes of this effect are under investigation.

14 SOLAR ENERGY↗

Extreme Weather Impact on PV - Resilience Lessons for Long-Term Performance

Aside from the immediate, visible damage, extreme weather events have a longer lasting impact on PV systems. Here, NREL's Dirk C. Jordan, Kirsten Perry, Robert White, Josh Parker, Byron McDanold and Chris Deline report on research revealing the long-term consequences of hail, wind and other weather phenomena on PV production

14 SOLAR ENERGY↗

Reducing Uncertainty of Fielded Photovoltaic Performance (Final Technical Report)

Improved analysis and reporting of photovoltaic (PV) field performance increases the certainty of owners and financiers that systems will perform as expected. Advanced module technologies (e.g., PERC, HJT, and bifacial) introduce new degradation mechanisms and performance characteristics. The FY19-21 Reducing Uncertainty project leveraged data from the ever-increasing PV fleet to develop models and understanding of the field performance of existing and new technologies. Specifically, we accomplished: report on field performance and degradation rates for high-efficiency silicon (HJT, PERC, IBC) and more conventional technologies; developed automated analysis techniques to quantify system performance (performance ratio, energy yield) and production shortfalls (soiling, degradation, availability); refined the RdTools software toolkit to bring standard, validated analysis techniques to bear on third-party data; analyzed and reported on large datasets including Treasury data and Lawrence Berkeley National Laboratory's Utility-Scale dataset to expand the high-quality degradation-rate histogram published previously; worked with industry partners and the DuraMAT data hub to enable private parties to share and aggregate PV production data anonymously, leveraging cloud-based data analysis infrastructure and publishing on US fleet-scale performance comprising over 7GW of operating systems. (https://www.nrel.gov/pv/fleet-performance-data-initiative.html). Through our industry collaborations we have engaged in NDA-covered data transfer with twelve PV fleet owners as of January 2022, with more agreements in negotiation. Our scalable cloud-based time series database contains over 30 billion rows (20TB) of PV time series data, representing over 1700 commercial and utility-scale systems, and over 7.2 GW of DC capacity (Fig 1). Initial field performance results have been distributed in several public reports. Because our fleet composition and data quality methods are continually improving, annual updates to these results are published to our PV Fleet webpage [ https://www.nrel.gov/pv/fleet-performance-data-initiative.html ] and DuraMAT data hub [DOI: 10.21948/1842958]. Another existing dissemination channel used for observed soiling losses is a map we maintain for soiling losses. Additional products developed include a report detailing fleet-wide performance index, availability, startup loss and snow loss factors, a detailed report on the 1603 grant dataset comprising over 100,000 PV systems with failure and performance details and a utility-scale report coauthored with LBNL on 31 GW of system performance.

14 SOLAR ENERGY↗

Photovoltaic fleet degradation insights

Abstract In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m 2 . Causes for this technology‐dependent behavior are under investigation.

14 SOLAR ENERGY↗

Automated detection of photovoltaic cleaning events: A performance comparison of techniques as applied to a broad set of labeled photovoltaic data sets

Extracting accurate soiling loss information from photovoltaic (PV) production data first requires segmenting the time series data per natural or manually occurring cleaning events. Maintenance logs are often incomplete, rain data are often unavailable, and the debate on rain thresholds for cleaning and dew or wind cleanings is still ongoing. The present work aims to overtake these issues by improving automated methods to detect these cleaning events and therefore improve extraction of soiling loss information. Time series power production data from 22 PV inverters were labeled for natural or manually occurring cleaning events. The data sets were carefully selected to include varying degrees of soiling, cleaning events, and noise. Several algorithms, including filtering logic and change point detection, were examined for efficacy at detecting the labeled cleanings. All the methods introduced except for changepoint detection showed significant improvement at detecting the labeled cleaning events per the mean F 1 score. Furthermore, the highest performing cleaning detection algorithm achieved an absolute increase in the mean F 1 score of 43% over the default version of the RdTools stochastic rate and recovery (SRR) algorithm. The highest performing algorithm included irradiance filtering and a cleaning detection threshold, adjusted based on the 40-day centered rolling median of the absolute day-to-day deviations in the daily performance index (PI). Furthermore, these improvements are promising as cleaning detection is an essential step in the automated analysis of PV soiling.

14 SOLAR ENERGY↗

Photovoltaic Data Acquisition (PVDAQ) Public Datasets

The NREL PVDAQ is a large-scale time-series database containing system metadata and performance data from a variety of experimental PV sites and commercial public PV sites. The datasets are used to perform on-going performance and degradation analysis. Some of the sets can exhibit common elements that effect PV performance (e.g. soiling). The dataset consists of a series of files devoted to each of the systems and an associated set of metadata information that explains details about the system hardware and the site geo-location. Some system datasets also include environmental sensors that cover irradiance, temperatures, wind speeds, and precipitation at the site.

Array↗