Metrics for implosion performance with enhanced energy coupling on NIF
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Patel, P.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We are reporting on a series of indirect-drive 0.9-scale CH capsule implosions (inner radius = 840 μm) fielded in low gas-fill (0.6 mg/cm 3 ) hohlraums of 6.72 mm diameter at the National Ignition Facility. Thanks to the 11%-reduction of the capsule size at a given hohlraum diameter compared to previously tested full-scale capsules, we achieved good hot spot symmetry control near 33% cone-fraction and without the need to invoke cross beam energy transfer. As a result, we achieved a hot spot pressure of 280 ± 40 Gbar, which is the highest pressure demonstrated in layered DT implosions with CH capsules to date. Pushing this design to higher velocity resulted in a reduction of neutron yield. Highly resolved capsule simulations suggest that higher Au M-shell preheat resulted in an increase in Atwood number at the ablator–ice interface, which leads to increased fuel-ablator instability and mixing. The results reported here provide important scaling information for next-generation CH designs.
Abstract not provided
We have developed and fielded x-ray penumbral imaging on the National Ignition Facility in order to enable sub-10 μm resolution imaging of stagnated plasma cores (hot spots) of spherically shock compressed spheres and shell implosion targets. By utilizing circular tungsten and tantalum apertures with diameters ranging from 20 μm to 2 mm, in combination with image plate and gated x-ray detectors as well as imaging magnifications ranging from 4 to 64, we have demonstrated high-resolution imaging of hot spot plasmas at x-ray energies above 5 keV. Here we give an overview of the experimental design criteria involved and demonstrate the most relevant influences on the reconstruction of x-ray penumbral images, as well as mitigation strategies of image degrading effects like over-exposed pixels, artifacts, and photon limited source emission. We describe experimental results showing the advantages of x-ray penumbral imaging over conventional Fraunhofer and photon limited pinhole imaging and showcase how internal hot spot microstructures can be resolved.
Abstract not provided
Objective: To investigate the prognostic significance of image gradients and in predicting clinical outcomes in a patients with non-small cell lung cancer treated with stereotactic body radiotherapy (SBRT) on 71 patients with 83 treated lesions. Methods: The records of patients treated with lung SBRT were retrospectively reviewed. When applicable, SBRT target volumes were modified to exclude any overlap with pleura, chestwall, or mediastinum. The ITK software package was utilized to generate quantitative measures of image intensity, inhomogeneity, shape morphology and first and second-order CT textures. Multivariate and univariate models containing CT features were generated to assess associations with clinicopathologic factors. Results: On univariate analysis, tumor size (HR 0.54, p=0.045) sumHU (HR 0.31, p=0.044) and short run grey level emphasis STD (HR 0.22, p=0.019) were associated with regional failure-free survival; meanHU (HR 0.30, p=0.035), long run emphasis (HR 0.21, p=0.011) and long run low grey level emphasis (HR 0.14, p=0.005) was associated with distant failure-free survival (DFFS). No features were significant on multivariate modeling however long run low grey level emphasis had a hazard ratio of 0.12 (p=0.061) for DFFS. Adenocarcinoma and squamous cell carcinoma differed with respect to long run emphasis STD (p=0.024), short run low grey level emphasis STD (p<0.001), and long run low grey level emphasis STD (p=0.024). Multivariate modeling of texture features associated with tumor histology was used to estimate histologies of 18 lesions treated without histologic confirmation. Of these, MVA suggested the same histology as a prior metachronous lung malignancy in 3/7 patients. Conclusion: Extracting radiomics features on clinical datasets was feasible with the ITK package with minimal effort to identify pre-treatment quantitative CT features with prognostic factors for distant control after lung SBRT.
Purpose: To evaluate the variations in dwell times and doses expected when using an episcleral brachytherapy device for treatment of neovascular agerelated macular degeneration (n-AMD) based on accurate imaging modalities Methods: Data from 40 eyes from 40 subjects with known n- AMD acquired through the Distance of Choroid Study (DOCS) conducted at Moorfields Eye Hospital was used to determine the target depth; the distance from the outer scleral surface of the eye, through the choroid, to the apex of the choroidal neovascularization (CNV). Each subject underwent, in triplicate, enhanced-depth Spectral Domain Optical Coherence Tomography (SD-OCT), Swept Source Optical Coherence Tomography, (SS-OCT) and Ocular Ultrasound (O-US). These data are the most comprehensive and accurate measurements of the dimensions of the CNV and adjacent layers of the eye for this cohort of patients. During treatment of n-AMD, patients receive a dose of 24Gy to the apex at the target depth. Using the percentage depth dose for a Sr-90 episcleral brachytherapy device, dwell times and doses to the apex were computed to determine the expected variations. Results: The mean target depth and the 95% confidence interval (CI) determined by combining O-US with SD-OCT were 1326 (956,1696)µm and with SS-OCT were 1332 (970,1693)µm. The calculated corresponding mean dwell times and 95% (CI) were 334 (223,445)s and 335 (226,445)s for SD-OCT and SS-OCT determined depths, respectively. The corresponding mean apex dose and 95% (CI) were 24 (35.9,18.0)Gy (SD-OCT) and 24 (35.6,18.1)Gy (SS-OCT). Conclusion: For episcleral brachytherapy treatment of n-AMD, using a patient population average target depth for treatment planning is inadequate, resulting in dose variations of a factor of approximately two over the 95% CI and larger variations for a nontrivial segment of the population. Each patient should have individualized imaging studies to determine the target depth for use in the dwell time calculation. Study was sponsored by Salutaris Medical Devices, Ltd., a subsidiary of Salutaris Medical Devices, Inc. Hamilton and Marsteller are founders of Salutaris Medical Devices, Inc. Drew, McGovern and Vitali are minor equity holders in Salutaris Medical Devices, Inc.
Mode 1 radiation drive asymmetry (pole-to-pole imbalance) at significant levels can have a large impact on inertial confinement fusion implosions at the National Ignition Facility (NIF). This asymmetry distorts the cold confining shell and drives a high-speed jet through the hot spot. The perturbed hot spot shows increased residual kinetic energy and reduced internal energy, and it achieves reduced pressure and neutron yield. The altered implosion physics manifests itself in observable diagnostic signatures, especially the neutron spectrum which can be used to measure the neutron-weighted flow velocity, apparent ion temperature, and neutron downscattering. Numerical simulations of implosions with mode 1 asymmetry show that the resultant simulated diagnostic signatures are moved toward the values observed in many NIF experiments. The diagnostic output can also be used to build a set of integrated implosion performance metrics. The metrics indicate that P{sub 1} has a significant impact on implosion performance and must be carefully controlled in NIF implosions.
Abstract not provided
The recent development of petawatt-class lasers with kilojoule-picosecond pulses, such as OMEGA EP [L. Waxer et al., Opt. Photonics News 16, 30 (2005)], provides a new diagnostic capability to study inertial-confinement-fusion (ICF) and high-energy-density (HED) plasmas. Specifically, petawatt OMEGA EP pulses have been used to backlight OMEGA implosions with energetic proton beams generated through the target normal sheath acceleration (TNSA) mechanism. This allows time-resolved studies of the mass distribution and electromagnetic field structures in ICF and HED plasmas. This principle has been previously demonstrated using Vulcan to backlight six-beam implosions [A. J. Mackinnon et al., Phys. Rev. Lett. 97, 045001 (2006)]. The TNSA proton backlighter offers better spatial and temporal resolution but poorer spatial uniformity and energy resolution than previous D{sup 3}He fusion-based techniques [C. Li et al., Rev. Sci. Instrum. 77, 10E725 (2006)]. A target and the experimental design technique to mitigate potential problems in using TNSA backlighting to study full-energy implosions is discussed. The first proton radiographs of 60-beam spherical OMEGA implosions using the techniques discussed in this paper are presented. Sample radiographs and suggestions for troubleshooting failed radiography shots using TNSA backlighting are given, and future applications of this technique at OMEGA and the NIF are discussed.
The physics issues involved in scaling from sub ignition to high gain fast ignition are discussed. Successful point designs must collimate the electrons and minimize the stand off distance to avoid multi mega-joule ignition energies. Collimating B field configurations are identified and some initial designs are explored.
Transparent armor is a material or system of materials designed to be optically transparent, yet protect from fragmentation or ballistic impacts. Although engineered to defeat specific threats, or a range of threats, there are general requirements common to all of these designs. The primary requirement for a transparent armor system is to not only defeat the designated threat but also provide a multi-hit capability with minimized distortion of surrounding areas. Ground platforms have several parameters that must be optimized, such as weight, space efficiency, and cost versus performance. Glass exhibits tensile failure stress that is very much dependent on the amount of material being stressed, the side being tensile-stressed (i.e., air-versus tin-side if a float glass), and where it is being tensile stressed (i.e., in the middle or near an edge). An axiom arising from those effects is a greater amount of allowable deflection (i.e., higher failure stress) of a ballistically impacted transparent armor will result in improved ballistic resistance. Therefore, the interpretation and management of those tensile-failure-stress dependencies shall ultimately improve ballistic resistance and its predictability of transparent armor. Each of those three dependencies (size, side, and location) in a soda-lime silicate glass is described.
In this paper we report on the radiography of a shock-compressed target using laser produced proton beams. A low-density carbon foam target was shock compressed by long pulse high-energy laser beams. The shock front was transversally probed with a proton beam produced in the interaction of a high intensity laser beam with a gold foil. We show that from radiography data, the density profile in the shocked target can be deduced using Monte Carlo simulations. By changing the delay between long and short pulse beams, we could probe different plasma conditions and structures, demonstrating that the details of the steep density gradient can be resolved. This technique is validated as a diagnostic for the investigation of warm dense plasmas, allowing an in situ characterization of high-density contrasted plasmas.
Abstract not provided
Diamond-like nanocomposite (DLN) thin films, comprising the networks of a-C:H and a-Si:O were deposited on pyrex glass or silicon substrate using gas precursors (e.g., hexamethyldisilane, hexamethyldisiloxane, hexamethyldisilazane, or their different combinations) mixed with argon gas, by plasma enhanced chemical vapor deposition technique. Surface morphology of DLN films was analyzed by atomic force microscopy. High-resolution transmission electron microscopic result shows that the films contain nanoparticles within the amorphous structure. Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, and x-ray photoelectron spectroscopy (XPS) were used to determine the structural change within the DLN films. The hardness and friction coefficient of the films were measured by nanoindentation and scratch test techniques, respectively. FTIR and XPS studies show the presence of C-C, C-H, Si-C, and Si-H bonds in the a-C:H and a-Si:O networks. Using Raman spectroscopy, we also found that the hardness of the DLN films varies with the intensity ratio I{sub D}/I{sub G}. Finally, we observed that the DLN films has a better performance compared to DLC, when it comes to properties like high hardness, high modulus of elasticity, low surface roughness and low friction coefficient. These characteristics are the critical components in microelectromechanical systems (MEMS) and emerging nanoelectromechanical systems (NEMS).
The use of a high-intensity plasma-arc lamp was used to irradiate the surface of soda-lime silicate glass tiles to determine if an increase in strength could be achieved. The lamp had a power density of 3500 W/cm2, a processing area of 1 cm x 10 cm, irradiated near-infrared heating at a wavelength between 0.2 1.4 m, and was controlled to unidirectionally sweep across 50-mm-square tiles at a constant speed of 8 mm/s. Ring-on-ring (RoR) equibiaxial flexure and 4 pt uni-directional flexure testings of entire tiles were used to measure and compare failure stress distributions of treated and untreated glass. Even with non-optimized processing conditions, RoR failure stress increased by approximately 25% and the 4 pt bend failure stress increased by approximately 65%. Strengthening was due to a fire-polishing-like mechanism. The arc-lamp heat-treatment caused the location of the strength-limiting flaws in the 4-pt-bend tiles to change; namely, failure initiation occurred on the gage section surface for the treated glass whereas it occurred at a gage section edge for the untreated. Arc-lamp heat-treatment is attractive not only because it provides strengthening, but because it can (non-contact) process large amounts of glass quickly and inexpensively, and is a process that either a glass manufacturer or end-user can readily employ.