Engineering Papers⌕ Search

Engineering topics

Moseley, S. H.

Publications and source records attributed to Moseley, S. H..

At least 91 records · Page 5

A monolithic Si bolometer array for the Caltech Submillimeter Observatory

We are developing a submillimeter continuum camera for the Caltech Submillimeter Observatory (CSO) located on Mauna Kea. The camera will employ a monolithic Si bolometer array which was developed by Moseley et al. at the NASA Goddard Space Flight Center (GSFC). The camera will be cooled to a temperature of about 300 mK in a He-3 cryostat, and will operate primarily at wavelengths of 350 and 450 micrometers. We plan to use a bolometer array with 1x24 directly illuminated pixels, each pixel of dimension 1x2 sq mm, which is about half of the F/4 beam size at these wavelengths. Each pixel is 10 to 12 micrometers thick and is supported only by four thin Si legs formed by wet chemical etch. The pixels are doped n-type by phosphorus implantation, compensated by boron implantation. Signals from the bolometer pixels are first amplified by cryogenically cooled FET's. The signals are further amplified by room-temperature amplifiers and then separately digitized by 16 bit A/D converters with differential inputs. The outputs of the A/D converters are fed into a digital signal processing board via fiber-optic cables. The electronics and data acquisition system were designed by the Goddard group. We will report the status of this effort.

Wang, Ning↗

High-resolution mid-infrared spectra of Co II, Ni I, and Fe II in SN 1987A

Ground-based infrared observations of SN 1987A on day 612 after the explosion have yielded resolved line profiles of Co II, Ni I, Fe II at 10.52, 11.31, and 17.94 micron, respectively. The spectra were taken at a resolving power of about 1000 with an array grating spectrometer on the 4 m telescope of Cerro Tololo Inter-American Observatory. Based on the observed line intensities we have estimated the minimum mass of each ion: M(Co II) = (6.0 +/- 1.8) x 10 exp -5 solar mass; M(Ni I) = (1.1 +/- 0.1) x 10 exp -3 solar mass; and M(Fe II) = (8.0 +/- 1.5) x 10 exp -3 solar mass. From these we infer total masses for cobalt, nickel, and iron in the ejecta. The nickel and iron line profiles are markedly asymmetric. We interpret these as arising from two components, one centered on the stellar rest velocity with an approximately 3250 km/s full width, and the second at about +1200 km/s with an approximately 1100 km/s full width. The asymmetry may represent a large-scale fracturing of the ejecta by Rayleigh-Taylor instabilities.

Jennings, D. E.↗

Superconducting Al-trilayer tunnel junctions for use as X-ray detectors

Photolithographic techniques have been developed to fabricate high-quality Al-Al oxide-Al superconducting tunnel junctions for use in X-ray detectors. These devices are designed to incorporate about 1-micron-thick superconducting X-ray absorbers for the detection of less than 10-keV single photons. In an effort to increase energy resolution, superconductor bandgap engineering with lateral and vertical trapping has been used to shorten quasi-particle tunneling times and diffusion lengths and to prevent quasi-particle diffusion away from the tunnel junction. Methods that have been developed for overcoming materials imcompatibility and device degradation upon thermal cycling are reported. The authors also report on the use of a nonrectangular tunnel junction geometry which reduces the magnetic field needed to suppress the Josephson current for stable biasing. Work in progress to measure the energy resolution of these X-ray detectors at 0.35 K is also discussed.

Gaidis, M. C.↗

X ray microcalorimeters: Principles and performance

Microcalorimeters operating at cryogenic temperatures can be excellent X-ray spectrometers. They simultaneously offer very high spectral resolving power and high efficiency. These attributes are important for X-ray astronomy where most sources have low fluxes and where high spectral resolution is essential for understanding the physics of the emitting regions. The principles of operation of these detectors, limits to their sensitivity, design considerations, techniques of fabrication, and their performance as X-ray spectrometers, are reviewed.

Moseley, S. H.↗

Dust and gas contributions to the energy output of SN 1987A on day 1153

SN 1987A spectra at 16-30 microns taken on days 1152 and 1154 after core collapse are presented. The observations are used to derive the mass of radiating Fe II in the ejecta, the mass and temperature of the dust that gives rise to the continuum emission, and the bolometric luminosity of the SN. The observed luminosity requires that the Co-57/Co-56 mass production rate be enhanced by a factor of (4.5 +/- 1.6) compared to its solar value, if 0.0001 solar mass of Ti-44 were produced in the ejecta.

Dwek, E.↗

Thermal detectors for X-ray astronomy - Current performance and limitations

We have been developing thermal detectors for X-ray astronomy. These detectors have the advantages of both high energy resolution and high quantum efficiency. A practical detector operating at a temperature of 0.1 K could ideally have a resolution as good as 1 eV (FWHM). We have produced a detector with a measured resolution of 7 eV (FWHM) for 6 keV X-rays. The detailed behavior of the detector thermistor and thermal links impose limits on performance. Techniques for improving detector behavior will be discussed. We are currently constructing an instrument for launch on a sounding rocket to observe the soft X-ray emission from the interstellar medium.

Juda, M.↗

Observations of 40-70 micron bands of ice in IRAS 09371 + 1212 and other stars

IRAS 09371 + 1212 is still an absolutely unique object. This M giant star, with circumstellar CO and a spectacular bipolar nebula, displays unique IRAS FIR colors which had been attributed to strong emission in the 40-70-micron bands of ice, as subsequently supported by the observation of a strong 3.1-micron absorption band. The results of the KAO observations have confirmed its unusual nature: the far-infrared bands of ice are by far the strongest known. Its dust temperature, 50 K or less, is by far the lowest known for a late-type circumstellar envelope.

Omont, A.↗

Far-infrared spectrophotometry of SN 1987A - Days 265 and 267

The paper presents 16-66-micron spectra of SN 1987A taken on days 266 and 268 after core collapse. The spectrum consists of a nearly flat continuum, strong emission lines of hydrogen, and fine-structure lines of Fe II, Fe III, Co II, S I, and possibly Fe I, Ni II, and S III. From the relative strength of three lines which arise from transitions within the ground and excited states of Fe II, the temperature and a lower limit on the density of the line-emitting region are derived. From the line strengths, the abundances of Fe and S I, the end products of explosive nucleosynthesis in the supernova are estimated. An upper limit is also set to the amount of Co II remaining in the mantle. The low measured mass of Fe suggests that the ejecta are clumpy. The flat continuum is most likely free-free emission from the expanding supernova ejecta. About 35 percent of this emission arises from the ionized metals in the mantle; the rest arises from ionized hydrogen. At the time of these observations, there is no evidence for any emission from dust that may have formed in the supernova ejecta or from preexisting dust in the surrounding medium.

Moseley, S. H.↗

Construction and performance of a high-temperature-superconductor composite bolometer

A high-Tc superconducting bolometer has been constructed using a YBa2Cu3O(x) thin-film meander line 20 microns wide and 76,000 microns long, deposited on a SrTiO3 substrate. Radiation is absorbed by a thin film of Bi with well-characterized absorption properties deposited on a Si substrate in contact with the SrTiO3. At 1.8 Hz the measured bolometer response to a 500-K blackbody is 5.2 V/W (820 V/W extrapolated to dc). The impact of apparent nonohmic behavior at the transition is discussed, as are ways of reducing the observed 1/f noise. The response time is 32 s and is dominated by the heat capacity of the SrTiO3 substrate.

Brasunas, J. C.↗

Observations of 40-70 micron bands of ice in IRAS 09371+1212 and other stars

The observations of the M giant star, IRAS 09371+1212, in the 40 to 70 microns emission bands, are reported. This star has a circumstellar CO envelope, and a unique infrared color, attributed to ice emission bands. The observations performed in February 1988, using grating spectrometer, showed that the far infrared bands of ice are the strongest known in the sky, and that its dust temperature (50K) is the lowest known for a circumstellar envelope. The 43 microns band of ice is also detected in several very cold circumstellar envelopes.

Omont, A.↗

Far-infrared observations of thermal dust emission from supernova 1987A

Observations of SN1987A in the spectral range 18-35 microns taken on November 16 and 23, 1988, 632 and 639 days after core collapse, are reported. A strong and rather flat continuum underlies weak fine-structure lines from heavy elements and declines slowly between 24 and 30 microns. The spectral shape indicates thermal emission from an almost featureless dust component, probably graphite, with silicates contributing less than 20 percent of the emitting dust mass. Some of the emission may be an 'echo' of supernova light reflected from a preexisting dust cloud, but a better explanation which can account for the entirety of emission from infrared to gamma wavelengths, is that dust is being formed in the supernova ejecta. This also accounts more naturally for the inferred dust composition.

Moseley, S. H.↗

Postdispersion system for astronomical observations with Fourier transform spectrometers in the thermal infrared

A postdispersion system for astronomical observations with Fourier transform spectrometers in the thermal infrared has been developed which improves the sensitivity of radiation noise limited observations by reducing the spectral range incident on the detector. Special attention is given to the first-generation blocked impurity band detector. Planetary, solar, and stellar observations are reported.

Wiedermann, Guenter↗

Effects of ionizing radiation on cryogenic infrared detectors

The Diffuse Infrared Background Experiment (DIRBE) is one of three experiments to be carried aboard the Cosmic Background Explorer (COBE) satellite scheduled to be launched by NASA on a Delta rocket in 1989. The DIRBE is a cryogenic absolute photometer operating in a liquid helium dewar at 1.5 K. Photometric stability is a principal requirement for achieving the scientific objectives of this experiment. The Infrared Astronomy Satellite (IRAS), launched in 1983, which used detectors similar to those in DIRBE, revealed substantial changes in detector responsivity following exposure to ionizing radiation encountered on passage through the South Atlantic Anomaly (SAA). Since the COBE will use the same 900 Km sun-synchronous orbit as IRAS, ionizing radiation-induced performance changes in the detectors were a major concern. Here, ionizing radiation tests carried out on all the DIRBE photodetectors are reported. Responsivity changes following exposure to gamma rays, protons, and alpha particle are discussed. The detector performance was monitored following a simulated entire mission life dose. In addition, the response of the detectors to individual particle interactions was measured. The InSb photovoltaic detectors and the Blocked Impurity Band (BIB) detectors revealed no significant change in responsivity following radiation exposure. The Ge:Ga detectors show large effects which were greatly reduced by proper thermal annealing.

Moseley, S. H.↗

Characterization of feedback resistors for cryogenic applications

Results are presented on the testing of feedback resistors selected for use in the transimpedance amplifiers (TIAs) in the Diffuse Infrared Background Experiment (DIRBE) to be flown on the NASA's Cosmic Background Explorer satellite planned for a launch in 1989. The resistors without encapsulation were found to be reliable as cryogenic circuit elements. Their resistance is sufficiently high (so that their Johnson noise does not dominate amplifier noise at the signal frequency), and they are sufficiently linear; no correction need to be made for signals up to 1.5 V, the 100,000 signal-to-noise level for the DIRBE, which covers most of the signals expected to be seen on the sky.

Lakew, B.↗

Progress in kinetic inductance thermometers for X-ray calorimeters

Conventional X-ray microcalorimeters have so far used ionimplanted resistors for thermometers. Recently, however, several new methods for sensing small temperature changes have been suggested that are nondissipative. Such devices may have intrinsically better energy resolution by eliminating the Johnson noise present in resistive devices. The use of kinetic inductance thermometers for X-ray microcalorimeters is being investigated. This technique exploits the strong temperature dependence of magnetic penetration depth of thin superconducting films. The prototype system, designed for operation at 1.5 K, uses films of aluminum and tin. Once the expected temperature sensitivity and alpha particle detection have been demonstrated, aluminum will be replaced with titanium or another material with a suitable critical temperature and the device will be operated at 0.3 K. At this temperature, the energy resolution from thermal noise should be sufficiently good to allow X-ray detection.

Rawley, G. L.↗

Airborne 20-65 micron spectrophotometry of Comet Halley

Observations of Comet Halley with a grating spectrometer on board the Kuiper Airborne Observatory on four nights in Dec. 1985 to Apr. 1986 are reported. Low resolution 20 to 65 micrometer spectra of the nucleus with a 40 arcsec FWHM beam was obtained on 17 Dec. 1985, and on 15 and 17 Apr. 1986. On 20 Dec. 1985, only a 20 to 35 micrometer spectrum was obtained. Most of the data have been discussed in a paper where the continuum was dealt with. In that paper, models were fit to the continuum that showed that more micron sized particles of grain similar to amorphous carbon were needed to fit the spectrum than were allowed by the Vega SP-2 mass distribution, or that a fraction of the grains had to be made out of a material whose absorption efficiency fell steeper than lambda sup -1 for lambda greater than 20 micrometers. Spectra was also presented taken at several points on the coma on 15 Apr. which showed that the overall shape to the spectrum is the same in the coma. Tabulated values of the data and calibration curves are available. The spectral features are discussed.

Glaccum, William↗

Advances toward high spectral resolution quantum X-ray calorimetry

Thermal detectors for X-ray spectroscopy combining high spectral resolution and quantum efficiency have been developed. These microcalorimeters measure the energy released in the absorption of a single photon by sensing the rise in temperature of a small absorbing structure. The ultimate energy resolution of such a device is limited by the thermodynamic power fluctuations in the thermal link between the calorimeter and isothermal bath and can in principle be made as low as 1 eV. The performance of a real device is degraded due to noise contributions such as excess 1/f noise in the thermistor and incomplete conversion of energy into phonons. The authors report some recent advances in thermometry, X-ray absorption and thermalization, fabrication techniques, and detector optimization in the presence of noise. These improvements have resulted in a device with a spectral resolution of 17 eV FWHM, measured at 6 keV.

Moseley, S. H.↗

High resolution X-ray spectroscopy using microcalorimeters

The use of microcalorimeters for high-resolution, high quantum efficiency, nondispersive X-ray spectroscopy has been demonstrated over the past few years. In this paper, the principles of X-ray calorimetry are reviewed, and the results of ongoing X-ray tests using microcalorimetry are summarized. An approach to building an X-ray calorimeter spectrometer is discussed.

Kelley, R. L.↗