Neutron capture on Actinides studied with DANCE
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Mosby, Shea Morgan.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Neutron diagnosed subcritical experiments (NDSEs) aim to measure the fission chain decay of subcritical test objects initiated by neutrons from an external source. The ultimate goal of future NDSEs is to make such measurements on dynamic subcritical objects as they are imploded. In this work, as a step toward that goal, we made measurements on three static subcritical assemblies containing highly enriched uranium. Specifically, we measured the die-off of both fission gamma rays and neutrons, with nanosecond resolution over several hundred microseconds, relative to the emission time of neutrons from a source in close proximity to the subcritical objects. Additionally, as simulations are expected to play a key role in interpreting future NDSEs, we compared our data to detailed MCNP® calculations. There was good agreement between the data and MCNP over die-off times expected to be most important to future NDSEs, but there were significant differences at both earlier and later times. We attempted to reconcile these differences by several changes to the simulations. In particular, we found that reducing the 235U(n,n’) cross section to 80% of the current ENDF7.1 evaluation resulted in much better agreement.
Explore the source record for details and available documents.
The goal of the Chi-Nu experiment at the Los Alamos Neutron Science Center is to measure the prompt fission neutron spectra from major actinides using a double time-of-flight method with a pulsed, white incoming neutron source. Fission events are detected with a parallel-plate avalanche counter and outgoing neutrons are detected with either a 6 Li-glass or liquid scintillator detector array for low- or high-energy neutrons, respectively. A detector response matrix for the interaction of neutrons with the experimental environment for neutrons measured with the Chi-Nu 6 Li-glass detector array has been calculated to obtain a full understanding of the measured Chi-Nu data and also to allow for nearly instantaneous production of simulated Chi-Nu data spectra. Prompt fission neutron spectra corresponding to 19 incoming neutron energy ranges from 0.7-20 MeV have been extracted using the ratio-of-ratios method with Chi-Nu 6 Li-glass data on the neutron-induced fission of 235 U.
Explore the source record for details and available documents.
We describe progress developing the Device for Indirect Capture Experiments on Radionuclides (DICER) on flight path 13 at the Lujan Center at the Los Alamos Neutron Science Center (LANSCE). This capability is being developed to tightly constrain neutron-capture cross section on short-lived radioactive nuclides of high importance to weapons-program sponsors via neutron total cross section measurements on the same nuclides. In this report, we describe progress in this endeavor during October 2017 through September 2018.
No abstract provided.
We describe progress developing the Device for Indirect Capture Experiments on Radionuclides (DICER) on flight path 13 at the Lujan Center at the Los Alamos Neutron Science Center (LANSCE). This capability is being developed to tightly constrain neutron-capture cross section on short-lived radioactive nuclides of high importance to weapons-program sponsors via neutron total cross section measurements on the same nuclides. In this report, we describe progress in this endeavor during October 2017 through March 2018.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In recent years, neutron radiography and tomography have been applied at different beam lines at Los Alamos Neutron Science Center (LANSCE), covering a very wide neutron energy range. The field of energy-resolved neutron imaging with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as quantitative density measurements, was pioneered at the Target 1 (Lujan center), Flight Path 5 beam line and continues to be refined. Applications include: imaging of metallic and ceramic nuclear fuels, fission gas measurements, tomography of fossils and studies of dopants in scintillators. The technique provides the ability to characterize materials opaque to thermal neutrons and to utilize neutron resonance analysis codes to quantify isotopes to within 0.1 atom %. The latter also allows measuring fuel enrichment levels or the pressure of fission gas remotely. More recently, the cold neutron spectrum at the ASTERIX beam line, also located at Target 1, was used to demonstrate phase contrast imaging with pulsed neutrons. This extends the capabilities for imaging of thin and transparent materials at LANSCE. In contrast, high-energy neutron imaging at LANSCE, using unmoderated fast spallation neutrons from Target 4 [Weapons Neutron Research (WNR) facility] has been developed for applications in imaging of dense, thick objects. Using fast (ns), time-of-flight imaging, enables testing and developing imaging at specific, selected MeV neutron energies. The 4FP-60R beam line has been reconfigured with increased shielding and new, larger collimation dedicated to fast neutron imaging. The exploration of ways in which pulsed neutron beams and the time-of-flight method can provide additional benefits is continuing. We will describe the facilities and instruments, present application examples and recent results of all these efforts at LANSCE.
In this study, the 239 Pu(n,γ) cross section has been measured from 10 eV to 1.3 MeV as part of an experimental campaign using the Detector for Advanced Neutron Capture Experiments (DANCE). The work represents a significant advance in experimental technique, with improved systematic uncertainties in key regions in the keV to MeV regime. In general the results of prior work are confirmed with improved uncertainties, particularly at the highest incident neutron energies.
New prompt fission neutron spectrum measurements are reported for 235 U(n,f) reactions induced by neutrons with energies from 0.7 to 20 MeV. These measurements cover outgoing neutron energies from 2.5 MeV down to 10 keV, using an array of 6 Li-glass scintillators for neutron detection and a double time-of-flight technique. The neutrons were produced at the Weapons Neutron Research facility of the Los Alamos Neutron Science Center. A detailed MCNP ® model of the experimental equipment and the surrounding room was used to interpret the experimental results. Backgrounds were measured in situ, making use of the time-dependent singles rates of the various detectors with asynchronous readout from waveform digitizers. The results presented here have been included in a re-evaluation of the fission neutron spectra for this fissioning system, a description of which is presented elsewhere in this issue.
To enhance the capabilities of the DANCE array, a new detector array NEUANCE was developed to enable simultaneous measurements of prompt fission neutrons and γ rays. NEUANCE was designed and constructed using 21 stilbene organic scintillator crystals. It was installed in the central cavity of the DANCE array. Signals from the 160 BaF 2 detectors of DANCE and the 21 detectors of NEUANCE were merged into a newly designed high-density high-throughput data acquisition system. The excellent pulse shape discrimination properties of stilbene enabled detection of neutrons with energy thresholds as low as 30–40 keVee. A fission reaction tagging method was developed using a NEUANCE γ-ray or neutron signal. The probability of detecting a neutron from the spontaneous fission of 252 Cf using NEUANCE is 47%. New correlated data for prompt fission neutrons and prompt fission rays were obtained for 252 Cf using this high detection efficiency experimental setup. In conclusion, average properties of prompt fission neutron emission as a function of prompt fission γ-ray quantities were also obtained, suggesting that neutron and γ-ray emission in fission are correlated.
Properties of fission in U-233 were studied at the Los Alamos Neutron Science Center (LANSCE) at incident neutron energies from thermal to 40 MeV at both the Lujan Neutron Scattering Center flight path 12 and at WNR flight path 90-Left from Dec 2016 to Jan 2017. Fission fragments are observed in coincidence using a twin ionization chamber with Frisch grids. The average total kinetic energy (TKE) released from fission and fragment mass distributions are calculated from observations of energy deposited in the detector and conservation of mass and momentum. Accurate experimental measurements of these parameters are necessary to better understand the fission process and obtain data necessary for calculating criticality. The average TKE released from fission has been well characterized for several isotopes at thermal neutron energy, however, few measurements have been made at fast neutron energies. This experiment expands on previous successful experiments using an ionization chamber to measure TKE and fragment mass distributions of U-235, U-238, and Pu-239. This experiment requires the full spectrum of neutron energies and can therefore only be performed at a small number of facilities in the world. The required full neutron energy spectrum is obtained by combining measurements from WNR 90L and Lujan FP12 at LANSCE.
Twenty pellets of mock-up accident tolerant fuels UN-U3Si5 were produced at LANL and loaded in two rodlet/capsule assemblies. Tomographic imaging and diffraction measurements were performed to characterize these samples at the Flight-Path 5 and HIPPO beam lines at LANSCE/LANL between November 2016 and January 2017 as well as in August 2017. The entire ~10 cm long, ~1 cm diameter fuel volume could be characterized, however due to time constraints only 2 mm slices in 4mm increments were characterized with neutron diffraction and a 28mm subset of the entire sample was characterized with energy-resolved neutron imaging. The double encapsulation of the fuel into two steel containers does not pose a problem for the neutron analysis and the methods could be applied to enriched as well irradiated fuels.
There are many neutron-capture cross sections of importance to radiochemical diagnostics and nuclear forensics which are beyond the reach of direct measurements. Hence, we have been developing an apparatus on flight path (FP) 13 at target 1 at LANSCE for tightly constraining these cross sections via determination of the underlying physical quantities. FP-13 was initially a cold-neutron beam line for materials science and therefore required substantial modification for use for nuclear physics. In FY17, we made several improvements to FP-13, demonstrated improved performance due to these changes via measurements on a variety of samples, identified a few more needed improvements, and reconfigured the beam line to implement the most important of these. New measurements to assess the impact of the most recent improvement will commence when beam is restored to LANSCE. Although FP-13 has not yet reached the performance required for small radioactive samples, measurements on a gold sample have led to an important science result which we are preparing for publication.