Engineering Papers⌕ Search

Engineering topics

Mosby, Shea Morgan

Publications and source records attributed to Mosby, Shea Morgan.

At least 37 records · Page 2

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct measurement of 59 Ni( n, p ) 59 Co and 59 Ni( n, α ) 56 Fe at fast-neutron energies from 500 keV to 10 MeV

We report nuclear reaction data for neutron induced reactions on unstable nuclei are critical for a wide range of applications spanning studies of nuclear astrophysics, nuclear reactor designs, and radiochemistry diagnostics. However, nuclear data evaluations of the reaction cross sections are largely based on calculations due to the difficulty in performing this class of measurements and the resulting lack of experimental data. For neutron induced charged particle reactions at fast neutron energies, at the MeV scale, these cross section predictions are predominately driven by statistical Hauser-Feshbach calculations. In this work, we present partial and total 59 Ni(n, p) and 59 Ni(n, α) cross sections, measured directly with a radioactive 59 Ni target, and compare the results to the present nuclear data evaluations. In addition, the results from this work are compared to a recent study of the 59 Ni(n, xp) reaction cross section that was performed via an indirect surrogate ratio method. The expected energy trend of the cross section, based on the current work, is inconsistent with that of the surrogate work. This calls into question the reliability of that application of the surrogate ratio method and highlights the need for direct measurements on unstable nuclei, when feasible.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LANSCE Overview for NA-113 WANDA 2022 [Slides]

Attached are presentation materials providing summary levels of LANSCE accelerator technical capabilities and experimental beam line applications with their associated user communities. These presentations are being provided as input material for the plenary session to be delivered by NA-113 at the WANDA 2022 meeting.

43 PARTICLE ACCELERATORS↗

Total absorption spectroscopy measurement on neutron-rich 74,75 Cu isotopes

This paper reports on the first β-decay study of 74,75 Cu isotopes using the technique of total absorption spectroscopy (TAS). The experiment was performed at the National Superconducting Cyclotron Laboratory at Michigan State University using the Summing NaI(Tl) (SuN) detector. The Cu isotopes are good candidates to probe the single-particle structure in the region because they have one proton outside the Z = 28 shell. Comparing the β-decay intensity distributions in the daughter Zn isotopes to the theoretical predictions provides a stringent test of the calculations. The nuclei in this region are also identified as playing an important role in the astrophysical r-process. Furthermore, the measured β-decay intensity distributions provide essential nuclear physics inputs required to better understand heavy element nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Report for LANSCE Futures Spring 2021 Workshop Series

The Los Alamos Neutron Science Center (LANSCE) has a long and successful history of delivering high-impact science for NNSA missions. The breadth of science LANSCE delivers is enabled by a unique combination of beam power, flexibility, and authorization basis. Though LANSCE is entering its 50th year of operations, current plans for the stockpile require LANSCE capabilities beyond 2050. These requirements demand a technical conversation about the accelerator and the long-term scientific vision for the facility, so we convened a set of workshops to initiate that conversation. The LANSCE Futures workshops spanned three capability areas of LANSCE: dynamic radiography, scattering science, and nuclear science. Participants included the relevant experts from the programs sponsoring LANSCE, the experimentalists utilizing the end-stations, and accelerator systems experts. A final workshop combined the three focus areas to begin the conversation about capabilities that could meet future mission needs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of material isotopics and atom number ratio with α-particle spectroscopy for a NIFFTE fission Time Projection Chamber actinide target

In this work, we present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target using α-spectroscopy and mass spectrometry. The double-sided actinide target, with predominantly 239 Pu on one side and 235 U on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is needed to extract an absolute measurement fission cross-section ratio. The 239 Pu/ 235 U atom number ratio was measured with a combination of mass spectrometry and α-spectroscopy with a planar silicon detector achieving uncertainties of less than 1%. Different strategies for estimating isotopic concentration from the α-spectrum are presented to demonstrate the potential of these methods for non-destructive target assay. We found that a combination of fitting spectra with constraints from mass spectrometry, and summing counts in a region of the spectrum provided the most consistent results with the lowest uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status and prospects for the development of a Neutron Target Facility

Neutron-induced reactions are a topic of general interest, with scientific and technical impact ranging from nuclear energy and national security to the fundamental sciences. Details of the fission process are critically important for energy production and reactivity for applications, while transmutation reactions such as (n,γ) can contribute to application-specific diagnostic information as well as our understanding of stellar nucleosynthesis. As a result, there is a long history of global investment in the necessary facilities and scientific programs to study this important class of physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of neutron-induced reactions on natural carbon using an active target at neutron energies up to 22 MeV at LANSCE

A single crystal chemical vapor deposited (sCVD) diamond detector is used as an active target to measure neutron-induced reactions on natural carbon using the neutrons produced by spallation, with a broad energy spectrum at LANSCE. Additionally, the neutron-induced reactions are detected in the diamond as low as E n = 400 keV and up to approximately 100 MeV. Relative cross sections for C 12 ( n , α 0 ) , C 12 ( n , p 0 ) , C 12 ( n , d 0 + p 1 ) , and C 13 ( n , α 0 ) are reported up to E n = 22 MeV and comparisons on detected pulse-height spectra and detector response of scattering reactions are made with GEANT4 simulations using the ENDF/B-VIII.0 evaluated nuclear data library up to 20 MeV. The results are compared with past experimental data, including other works that incorporate diamond detectors as an active carbon target. In addition, R-matrix calculations for the C 13 + n system are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Late Prompt Fission Gamma Rays from 235 U(n,f) and 252 Cf(sf)

Two measurements of fission γ rays were performed with the DANCE and NEUANCE arrays using the reactions 235 U(n, f) and 252 Cf(sf). Utilizing the fast time response of the detectors and a method for estimating the accidental background, we obtained the energy spectrum of the late prompt fission γ rays as a function of the time since fission. The experimental results are compared with predictions of the code CGMF folded with GEANT4 simulations of the detector response.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Isotopically resolved neutron total cross sections at intermediate energies

The neutron total cross sections σ tot of 16,18 O, 58 64 Ni, 103 Rh, and 112,124 Sn have been measured at the Los Alamos Neutron Science Center from low to intermediate energies (3 ≤ E lab ≤ 450 MeV) by leveraging wave-form-digitizer technology. The σ tot relative differences between isotopes are presented, revealing additional information about the isovector components needed for an accurate optical-model description away from stability. Digitizer-enabled σ tot -measurement techniques are discussed and a series of uncertainty-quantified dispersive optical model (DOM) analyses using these new data is presented, validating the use of the DOM for modeling light systems ( 16,18 O) and systems with open neutron shells ( 58,64 Ni and 112,124 Sn). Here, the valence-nucleon spectroscopic factors extracted for each isotope reaffirm the usefulness of high-energy proton reaction cross sections for characterizing depletion from the mean-field expectation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 65 Cu(η, γ) cross section using the Detector for Advanced Neutron Capture Experiments at LANL

Improving our understanding of the origin of the elements in the observable universe as well as the nature of the environments responsible for their production has been of paramount importance to the nuclear physics community. More than half of the isotopes of these elements are created via neutron-capture processes, and thus accurate measurements of the salient underlying nuclear physics, such as neutron-capture cross sections, masses, and β-decay half-lives are crucial. Of particular signifcance to the synthesis of isotopes in the mass range of A ≈ 60 to A ≈ 90, via the weak s process, are the neutron-capture cross sections of 63,65 Cu, where large discrepancies between measurements exist. Recent measurements have addressed these discrepancies for 63 Cu [Weigand et al., Phys. Rev. C 95, 015808 (2017)], but questions still remain for 65 Cu. Here, we report a new measurement of the 65Cu(n, γ ) cross section performed using the Detector for Advanced Neutron Capture Experiments located at the Los Alamos Neutron Science Center of Los Alamos National Laboratory. The Maxwellian-averaged cross section (MACS) for 65 Cu(η, γ) at $kT$ = 30 keV deduced from this work is (37.0 ± 0.3 stat. ± 3.3 sys. ) mb. The impact on weak s-process nucleosynthesis of new MACS values, calculated over the range of kT = 5 to 100 keV, for 65 Cu, combined with the updated MACS for 63 Cu [Weigand et al., Phys. Rev. C 95, 015808 (2017)] and 63 Ni [Weigand et al., Phys. Rev. C 92, 045810 (2015)], were investigated. Findings of this investigation show an increase of predicted nucleosynthesis yields of elements of Zn to Zr by as much as 20%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Statistical neutron capture in the limit of low nuclear level density

A major barrier in the study of neutron-induced nuclear reactions is the impossibility of direct measurements with short-lived radioactive isotopes. For these exotic nuclei, theoretical inputs such as the Photon Strength Function (PSF) are poorly constrained. At Los Alamos National Laboratory, the Detector for Advanced Neutron Capture Experiments (DANCE) provides direct measurements of γ-ray cascades following neutron capture reactions on stable or long-lived radioactive nuclei. While Hauser-Feshbach calculations can provide reasonable predictions for neutron capture on heavy nuclei, their application to neutron-rich light nuclei with low nuclear level densities and low neutron separation energies is questionable. In this paper, we report on the γ-ray spectra from individual neutron resonances from the 96 Zr(n, γ) reaction, with an emphasis on the sensitivity of of the γ-ray spectra to different PSF models. The comparison of the measured γ-ray spectra with predicted spectra does not support the addition of a low-energy enhancement of the size reported in many charged-particle reaction measurements, but the sensitivity of the γ-ray spectra to different PSF models is weak.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗