Engineering Papers⌕ Search

Engineering topics

Menzies, R. T.

Publications and source records attributed to Menzies, R. T..

At least 73 records · Page 4

A re-evaluation of laser heterodyne radiometer ClO measurements

Previously reported measurements of stratospheric ClO using a balloon-borne laser heterodyne radiometer, launched from Palestine, Texas, are re-evaluated as a result of recent spectroscopic data. A spectral feature which was observed during September, 1978 and November, 1979 flights was incorrectly identified as a ClO absorption line, while a second feature observed during the latter flight with somewhat limited sensitivity is now believed to be due to ClO. This new interpretation results in a measured ClO profile which falls off more rapidly with decreasing altitude than the previous results indicated.

Menzies, R. T.↗

Spectrophone stabilization and offset tuning of a carbon dioxide waveguide laser

A sensitive spectrophone containing CO2 gas is incorporated into a feedback loop to stabilize the frequency of a CO2 waveguide laser. First or second harmonic detection combined with a zero offset feature and the relatively high operating pressure of the laser allows continuous tuning of the stabilized frequency over a 400 MHz range. Frequency stability of better than + or - 1 MHz is achieved.

Kavaya, M. J.↗

Mode selection and frequency tuning by injection in pulsed TEA-CO2 lasers

An analytical model characterizing pulsed-TEA-CO2-laser injection locking by tunable CW-laser radiation is presented and used to explore the requirements for SLM pulse generation. Photon-density-rate equations describing the laser mechanism are analyzed in terms of the mode competition between photon densities emitted at two frequencies. The expression derived for pulsed dye lasers is extended to homogeneously broadened CO2 lasers, and locking time is defined as a function of laser parameters. The extent to which injected radiation can be detuned from the CO2 line center and continue to produce SLM pulses is investigated experimentally in terms of the analytical framework. The dependence of locking time on the detuning/pressure-broadened-halfwidth ratio is seen as important for spectroscopic applications requiring tuning within the TEA-laser line-gain bandwidth.

Flamant, P. H.↗

Pulse evolution and mode selection characteristics in a TEA-CO2 laser perturbed by injection of external radiation

A grating-tunable TEA-CO2 laser with an unstable resonator cavity, modified to allow injection of CW CO2 laser radiation at the resonant transition line by means of an intracavity NaCl window, has been used to study the coupling requirements for generation of single frequency pulses. The width and shape of the mode selection region, and the dependence of the gain-switched spike buildup time and the pulse shapes on the intensity and detuning frequency of the injected radiation are reported. Comparisons of the experimental results with previously reported mode selection behavior are discussed.

Flamant, P. H.↗

Infrared laser optogalvanic spectroscopy of molecules

Infrared laser optogalvanic spectra of portions of the NH3 nu3 band at 9.5 microns and the NO2 nu3 band at 6.2 microns have been recorded using CW tunable diode lasers to probe dc electrical discharges in pure NH3 and an NO2/He gas mixture. Two contributions to the optogalvanic signal are identified: one which corresponds to an increase in discharge impedance and is seen only for irradiation of the negative glow region; and a second which corresponds to a decrease in discharge impedance and is seen for irradiation of all other discharge regions and the volume outside the interelectrode region. Mechanisms by which infrared laser irradiation may cause impedance changes in the discharge are proposed.

Webster, C. R.↗

A survey of laser and selected optical systems for remote measurement of pollutant gas concentrations

Applications of the Differential Absorption Lidar (DIAL) technique to the remote sensing of pollutant gases are surveyed. In the DIAl technique, the differential absorption of two laser beams reflected back to a receiver from a target determines the concentration of the gas being studied. The types of instruments available are considered in detail: dye lidar (to measure nitrogen dioxide, sulfur dioxide, and ozone); carbon dioxide laser (for ozone, ethylene, ammonia, and hydrazine), helium-neon laser (for methane); hydrogen fluoride laser (for HF); and tunable diode laser (for nitric oxide and carbon monoxide). DIAL instruments are compared with other optical remote sensors such as Fourier-transform infrared spectrometers, correlation spectrometers (COSPEC and GASPEC), and grating spectrometers; and criteria for the selection of an appropriate gas measuring system are suggested. Laser and other optical remote sensors are found to be cost effective in many cases, despite the fact that they are more costly than point-monitoring systems.

Grant, W. B.↗

Remote measurement of trace gases with the JPL laser absorption spectrometer

Extensive data from large regions are needed as a basis for the study of anthropogenic trace gases in the troposphere. The need arises, therefore, for an instrument which is capable to monitor rapidly the atmosphere in a region. The present investigation is concerned with the results of efforts to develop an instrument which is capable of remotely measuring gases in the troposphere. The Laser Absorption Spectrometer (LAS) was designed for use in aircraft, and was employed to measure tropospheric ozone distribution since 1977. Attention is given to a description of the LAS instrument, the theoretical basis of instrument operation, LAS measurement programs, the results of the LAS development program, and future work.

Shumate, M. S.↗

Lidar system analysis for measurement of atmospheric species

Several important aspects of lidar are discussed, which pertain to a system analysis of the applicability of certain types of lidar to specific measurement objectives. The differential absorption lidar (DIAL) technique is emphasized. A brief treatment of the DIAL technique is followed by a discussion of the comparison of DIAL with other lidar measurement techniques. Sensitivity expressions are presented for DIAL with either direct or coherent (heterodyne) detection systems. A treatment of the fundamental similarities and differences in using the UV and IR spectral regions for species measurements, such as backscattering properties, spectral characteristics of the absorbing species, and factors relevant to the optimization of the DIAL measurement accuracy, is also included. Finally, results obtained from an existing ground-based DIAL system used to measure water vapor profiles are briefly discussed.

Menzies, R. T.↗

Stratospheric species measurements with tunable diode laser absorption spectroscopy

A balloon-borne instrument for stratospheric research has been developed with the capability to simultaneously measure several chemically related species in situ, for a full diurnal cycle. The instrument utilizes tunable infrared diode lasers (TDLs) to provide the radiation in selected wavelength regions for sensitive absorption spectroscopy over a one-km round-trip path. The TDL radiation is directed to a remote retroreflector which is lowered 500 m below the instrument gondola. A HeNe laser and co-aligned TV camera with CID imaging are used for retroreflector tracking. Currently the instrument operates with two TDLs, and the capability exists to measure four stratospheric species: NO, NO2, O3, and H2O. The number of operating TDLs can be expanded to four, resulting in the possibility of measuring several additional trace species.

Menzies, R. T.↗

Tunable diode laser optogalvanic spectroscopy of molecules

The laser optogalvanic (LOG) technique for studying molecular spectra has been extended for the first time to the infrared wavelength region. Portions of the NH3 nu-2 band at 9.5 microns and the NO2 nu-3 band at 6.2 microns have been recorded at Doppler-limited resolution using CW tunable diode lasers to probe dc electrical discharges in pure NH3 and an NO2/He gas mixture. Using adjustable electrode positions and an orthogonal geometry between the probe laser and the discharge axis, two contributions to the optogalvanic signal are identified: one which corresponds to an increase in discharge impedance and is seen only for irradiation of the negative glow region; and a second which corresponds to a decrease in discharge impedance and is seen for irradiation of all other discharge regions.

Webster, C. R.↗

A tunable coherent CO2 lidar for measurements of atmospheric aerosol backscatter and attenuation

A coherent laser radar system using a grating-tunable, injection-locked TEA-CO2 transmitter is being used to measure the altitude dependence of atmospheric aerosol backscatter and attenuation at a variety of CO2 laser wavelengths in the 9-11 micron region. Injection control of the TEA-CO2 laser allows one to obtain Single-Longitudinal-Mode (SLM) pulses which will follow the frequency of the injected radiation if the TEA laser cavity length is adjusted so that a cavity resonance is in proximity with the injected signal frequency, and if various additional conditions are satisfied. Requirements for generation of SLM pulses in this manner from a TEA CO2 laser with an unstable resonator cavity will be discussed. Procedures used for quantitative range-gated measurements of aerosol backscatter and attenuation will also be discussed.

Menzies, R. T.↗

Linewidth measurements of tunable diode lasers using heterodyne and etalon techniques

Measurements of the linewidths of Pb-salt diode lasers operating in the 8- and 9-micron region are reported. The linewidths of the 9-micron lasers were determined by conventional heterodyne techniques, while for the 8-micron lasers a new technique based on a Fabry-Perot etalon was used. The new technique avoids the complexity and limited wavelength range of the heterodyne measurements and can be used for any tunable laser. The linewidths observed varied from 0.6 to more than 500-MHz FWHM. The linewidth was found to vary dramatically from device to device, to depend strongly on junction temperature and injection current, and to be correlated with vibrations caused by operation of a closed-cycle refrigerator.

Reid, J.↗

Dependence of injection locking of a TEA CO2 laser on intensity of injected radiation

The results of an experimental study to determine the minimum required injected power to control the output frequency of a TEA CO2 laser are reported. A CW CO2 waveguide laser was used as the injection oscillator. Both the power and the frequency of the injected radiation were varied, while the TEA resonator cavity length was adjusted to match the frequency of the injected signal. Single-longitudinal mode (SLM) TEA laser radiation was produced for injected power levels which are several orders of magnitude below those previously reported. The ratio of SLM output power to injection power exceeded 10 to the 12th at the lowest levels of injected intensity.

Oppenheim, U. P.↗

Aligning the transmitter and receiver telescopes of an infrared lidar A novel method

A method for aligning the transmitter and receiver telescopes of a lidar is proposed which involves the use of a small high-quality corner tube reflector placed immediately in front of the transmitter in such a way that a small fraction of the transmitted radiation is reflected to the receiver. The reflected radiation is brought to a focus in a focal plane where it appears as a small red dot and is superimposed on the image of the distant scene. The dot and the target appear in the same plane and may be brought to coincidence by moving the transmitter-receiver pair together until the image of the target falls on the red dot. The alignment is concluded by imaging the red dot onto an IR detector.

Oppenheim, U. P.↗

Optogalvanic stabilization and offset tuning of a carbon dioxide waveguide laser

A feedback loop employing the change in discharge impedance with output power is used to stabilize the frequency of a CO2 waveguide laser. The relatively high operating pressure of the laser combined with a zero offset feature in the feedback loop allows continuous tuning of the stabilized frequency over a 300-400 MHz range.

Kavaya, M. J.↗

Tunable pulsed carbon dioxide laser

Transverse electrically-excited-atmosphere (TEA) laser is continuously tunable over several hundred megahertz about centers of spectral lines of carbon dioxide. It is operated in single longitudinal mode (SLM) by injection of beam from continuous-wave, tunable-waveguide carbon dioxide laser, which serves as master frequency-control oscillator. Device measures absorption line of ozone; with adjustments, it is applicable to monitoring of atmospheric trace species.

Megie, G. J.↗

Balloon-borne laser heterodyne radiometer for measurements of stratospheric trace species

A laser heterodyne radiometer has been flown to measure chlorine monoxide in the stratosphere, which has an important role in the catalytic destruction of ozone. The measured values in the 35-38 km region are found to be significantly higher than model predictions, and the drop-off at lower altitudes occurs at a higher rate, even after adjusting the profile to include the solar zenith angle effects.

Menzies, R. T.↗

Laser absorption spectrometer - Remote measurement of tropospheric ozone

The laser absorption spectrometer (LAS) is an airborne instrument able to perform remote measurement of trace atmospheric gases. The instrument uses a pair of carbon dioxide laser-heterodyne receiver systems that are directed downward from an airplane and determines gas concentration by the differential absorption method. Configured to measure tropospheric ozone, the LAS has been used in conjunction with another instrumented aircraft to test the accuracy of this method of measurement. A complete description of the instrument is presented, and the results of extensive flight testing are summarized.

Shumate, M. S.↗