On the use of the cross section concept as applied to pulsed CO2 laser dynamics

The 'cross sections' which are commonly used in combination with the molecular vibrational level densities to describe induced transition rates are time dependent in a pulsed discharge. This greatly affects the relative rates of buildup of radiation at the various lines of a molecular gain medium in a nondispersive cavity, and the consequences for line selection by injection in a TEA-CO2 laser are discussed.

Flamant, P. H.↗

Digital control of diode laser for atmospheric spectroscopy

A system is described for remote absorption spectroscopy of trace species using a diode laser tunable over a useful spectral region of 50 to 200 cm(-1) by control of diode laser temperature over range from 15 K to 100 K, and tunable over a smaller region of typically 0.1 to 10 cm(-1) by control of the diode laser current over a range from 0 to 2 amps. Diode laser temperature and current set points are transmitted to the instrument in digital form and stored in memory for retrieval under control of a microprocessor during measurements. The laser diode current is determined by a digital to analog converter through a field effect transistor for a high degree of ambient temperature stability, while the laser diode temperature is determined by set points entered into a digital to analog converter under control of the microprocessor. Temperature of the laser diode is sensed by a sensor diode to provide negative feedback to the temperature control circuit that responds to the temperature control digital to analog converter.

Menzies, R. T.↗

Laser Pollutant-Measuring Systems

Laser optical system for remote gas pollutant measurements surveyed. Laser systems discussed in published report, and choices of appropriate gasmeasuring instruments and their sensitivities evaluated.

Grant, W. B.↗

Microprocessor-controlled laser tracker for atmospheric sensing

An optical tracking system comprising a visible HeNe laser, an imaging detector, and a microprocessor-controlled mirror, has been designed to track a moving retroreflector located up to 500 m away from an atmospheric instrument and simultaneously direct spectrally tunable infrared laser radiation to the retroreflector for double-ended, long-path absorption measurements of atmospheric species. The tracker has been tested during the recent flight of a balloon-borne tunable diode laser absorption spectrometer which monitors the concentrations of stratospheric species within a volume defined by a 0.14-m-diameter retroreflector lowered 500 m below the instrument gondola.

Johnson, R. A.↗

Lasers in space

Hinkley and Herring (1984) have considered the differences between active (laser) and passive remote sensing from space. The conclusion was reached that spaceborne lasers will eventually complement passive sensors in providing information on the distributions of key atmospheric species and meteorological parameters. Precise information can also be obtained of ice sheet and crustal dynamics for geological and mapping applications. NASA initiated recently an airborne measurement program directed toward some of these objectives. The program employs optical radar (laser radar) systems onboard the NASA advanced ER-2 high-flying aircraft. The results of the experiments are to provide important information with respect to the potential utility of spaceborne laser remote sensing. A study indicated that a spaceborne pulsed carbon dioxide laser could measure tropospheric winds. Attention is also given to measurements of atmospheric gases by spaceborne lasers, solid-state lasers for spaceborne remote sensing, and laser communication in space.

Hinkley, E. D.↗

Precise Control of a Tunable IR Diode Laser

Tuning system applicable to lead-salt semiconductor tunable diode laser (TDL) and other solid-state lasers with temperature and current dependent emission wavelength developed for balloon borne, highresolution spectrometer that measures trace atmospheric constituents in stratosphere. Instrument measures absorption at approximately 20 points in 100 MHz wide spectral line.

Menzies, R. T.↗

High sensitivity detection of trace gases at atmospheric pressure using tunable diode lasers

A detailed study of the detection of trace gases at atmospheric pressure using tunable diode lasers is described. The influence of multipass cells, retroreflectors and topographical targets is examined. The minimum detectable infrared absorption ranges from 0.1 percent for a pathlength of 1.2 km to 0.01 percent over short pathlengths. The factors which limit this sensitivity are discussed, and the techniques are illustrated by monitoring atmospehric CO2 and CH4.

Reid, J.↗

Coherent and incoherent lidar - An overview

Characteristics of coherent and incoherent lidars are described. The carrier-to-noise ratio (CNR), SNR relationship, coherence diameter, speckle averaging, multiple pulse averaging, and the possibility of single-frequency pulse generation from the laser transmitter for the two lidar types are compared. Diagrams of the incoherent lidar's direct detection system and the coherent lidar's heterodyne detection system are presented. The transverse coherence diameter is discussed and equations for backscatter from a distributed medium, transverse coherence length, and return path refractive index variations are provided. The importance of transverse coherence length in the coherence lidar system design is considered. The effectiveness of the lidar systems is evaluated in terms of CNR and SNR. The differences in generation of noise-equivalent power are studied and it is observed that the coherent lidar system achieves higher CNR values. The relation between signal fluctuation due to speckle effects and SNR is analyzed; equations for SNR in coherent and incoherent lidar systems are given.

Menzies, R. T.↗

Visual Alinement Technique for Infrared LIDAR

Visible He/Ne laser beam substituted for invisible CO2 beam during alinement. System accomplished visually by using low-power He/Ne laser previously adjusted to visible beam parallel to invisible infrared CO2 laser beam. Method used to aline adjacent telescopes in other optical systems.

Menzies, R. T.↗

Tunable mode and line selection by injection in a TEA CO2 laser

Tunable mode selection by injection in pulsed CO2 lasers is examined, and both analytical and numerical models are used to compute the required injection power for a variety of experimental cases. These are treated in two categories: mode selection at a desired frequency displacement from the center frequency of a transition line in a dispersive cavity and mode (and line) selection at the center frequency of a selected transition line in a nondispersive cavity. The results point out the potential flexibility of pulsed injection in providing wavelength tunable high-energy single-frequency pulses.

Menzies, R. T.↗

Atmospheric aerosol backscatter measurements using a tunable coherent CO2 lidar

Measurements of atmospheric aerosol backscatter coefficients, using a coherent CO2 lidar at 9.25- and 10.6-micron wavelengths, are described. Vertical profiles of the volume backscatter coefficient beta have been measured to a 10-km altitude over the Pasadena, CA, region. These measurements indicate a wide range of variability in beta both in and above the local boundary layer. Certain profiles also indicate a significant enhancement in beta at the 9.25-micron wavelength compared with beta at the 10.6-micron wavelength, which possibly indicates a major contribution to the volume backscatter from ammonium sulfate aerosol particles.

Menzies, R. T.↗

Evidence for speckle effects on pulsed CO2 lidar signal returns from remote targets

A pulsed CO2 lidar was used to study statistical properties of signal returns from various rough surfaces at distances near 2 km. These included natural in situ topographic materials as well as man-made hard targets. Three lidar configurations were used: heterodyne detection with single temporal mode transmitter pulses, and direct detection with single and multiple temporal mode pulses. The significant differences in signal return statistics, due largely to speckle effects, are discussed.

Menzies, R. T.↗

In situ measurement of stratospheric nitric oxide using a balloon-borne tunable diode laser spectrometer

The stratospheric mixing ratio of nitric oxide at an altitude of 36 km has been measured using a balloon-borne tunable diode laser (TDL) instrument operating in the 5.2-micron wavelength region. Currently the instrument operates with two TDLs, and the capability exists to measure four stratospheric species simultaneously: NO, NO2, O3, and H2O. During the NO measurements reported here, the second TDL operating near 6.2 microns was used to monitor water vapor concentration in the vicinity of the gondola by observing the 1889.57 per cm line absorption in the reference channel path length (1 m).

Webster, C. R.↗

Aerosol backscatter lidar calibration and data interpretation

A treatment of the various factors involved in lidar data acquisition and analysis is presented. This treatment highlights sources of fundamental, systematic, modeling, and calibration errors that may affect the accurate interpretation and calibration of lidar aerosol backscatter data. The discussion primarily pertains to ground based, pulsed CO2 lidars that probe the troposphere and are calibrated using large, hard calibration targets. However, a large part of the analysis is relevant to other types of lidar systems such as lidars operating at other wavelengths; continuous wave (CW) lidars; lidars operating in other regions of the atmosphere; lidars measuring nonaerosol elastic or inelastic backscatter; airborne or Earth-orbiting lidar platforms; and lidars employing combinations of the above characteristics.

Kavaya, M. J.↗

Spectrophone stabilized laser with line center offset frequency control

Continuous offset tuning of a frequency stabilized CW gas laser is achieved by using a spectrophone filled with the same gas as the laser for sensing a dither modulation, detecting a first or second derivative of the spectrophone output with a lock-in amplifier, the detected output of which is integrated, and applying the integrator output as a correction signal through a circuit which adds to the dither signal from an oscillator a dc offset that is adjusted with a potentiometer to a frequency offset from the absorption line center of the gas, but within the spectral linewidth of the gas. Tuning about that offset frequency is achieved by adding a dc value to the detected output of the dither modulation before integration using a potentiometer.

Kavaya, M. J.↗

Target reflectance measurements for calibration of lidar atmospheric backscatter data

Wavelength and angular dependence of reflectances and depolarization in the 9-11 micron region are reported for four standard targets: flowers of sulfur, flame-sprayed aluminum, 20-grit sandblasted aluminum, and 400-grit silicon carbon sandpaper. Measurements are presented and compared using a CW CO2 grating-tunable laser in a laboratory backscatter apparatus, an integrating sphere, and a coherent pulsed TEA-CO2 lidar system operating in the 9-11 micron region. Reflectance theory related to the use of hard targets to calibrate lidar atmospheric backscatter data is discussed.

Kavaya, M. J.↗

Balloon-borne diode-laser absorption spectrometer for measurements of stratospheric trace species

An instrument has been designed for the measurement of stratospheric trace species which utilizes tunable infrared diode lasers as sources for sensitive in situ absorption spectroscopy in selected wavelength regions. This instrument, the Balloon-Borne Laser In Situ Sensor (BLISS), is a high-resolution absorption spectrometer designed to provide measurements of the concentrations of stratospheric species and their diurnal variations. The instrument employs second-harmonic detection of the absorption of tunable diode laser (TDL) radiation (3-30 microns) in a 1 km path length defined by a retroreflector lowered 0.5 km below the BLISS gondola. Retroreflector tracking under microprocessor control is obtained using a He-Ne laser and coaligned TV camera with CID imaging. Simultaneous measurements of molecular species in the 20-40 km altitude range will be performed using four TDLs, with the predicted minimum-detectable mixing ratio at 30 km being typically less than or equal to 0.1 ppbv.

Menzies, R. T.↗