Engineering Papers⌕ Search

Engineering topics

Mendoza, Paul Michael

Publications and source records attributed to Mendoza, Paul Michael.

Improved evaluation of safeguards parameters from spent fuel measurements with the Differential Die-Away (DDA) instrument

The Differential Die-Away (DDA) technique is a highly sensitive non-destructive assay method for characterizing and detecting the presence of fissile material within an item of interest. DDA utilizes a series of pulses from a neutron generator (NG) to actively interrogate an item of interest. The die-away time of the neutron population induced by this active interrogation and the integral of the total differential die-away signal can be used to characterize items such as nuclear waste drums and spent nuclear fuel assemblies. In this work, Los Alamos National Laboratory (LANL) conceptualized, designed, and fabricated a DDA instrument that was deployed for field test measurements at the Central Interim Storage Facility for Spent Nuclear Fuel (Clab) in Oskarshamn, Sweden. The instrument performed multiple static measurements at fixed locations and dynamic axial scans of 15 pressurized water reactor (PWR) and 10 boiling water reactor (BWR) spent fuel assemblies, collecting both passive and active measurement data. The static assays of the assemblies measured the differential die-away signal, die-away time, and total passive neutron emission rate to create calibration curves for the evaluation of assembly multiplication, burnup, initial enrichment, effective fissile mass, and total elemental plutonium mass. Each calibration curve was optimized by minimizing the relative root mean square error (RRMSE) of assembly assay results compared to declared assembly parameters. The same quantities were also measured with the axial scans, and the resulting data were applied in two ways: (1) in the creation of calibration curves to improve evaluation of the same safeguards parameters as static assays, and (2) for comparison to simulation. In most cases, across both PWR and BWR assemblies, axial scan data improved the estimation of the above parameters, quantified by decreasing the calibration curve RRMSE. These axial scan results demonstrate the ability of the DDA instrument and analysis method to characterize spent PWR and BWR fuel as well as, or better than, a static assay of the same assembly. Furthermore, the DDA instrument’s unique ability to obtain both active and passive data in a single, axial scan of an entire spent fuel assembly represents a more efficient and accurate way of assaying spent fuel for verification purposes. These results represent a significant advancement for characterizing spent nuclear fuel compared to current technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AWCC Simulations

Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗