Engineering Papers⌕ Search

Engineering topics

Meffert, Bill

Publications and source records attributed to Meffert, Bill.

The Value of Regression Models in Determining Industrial Energy Savings

Determination of industrial facility energy savings is commonly undertaken to comply with legal requirements, meet sustainability goals, and quantify greenhouse gas emissions, cost savings, and as one way to demonstrate energy performance improvement per the requirements of an energy management system standard, such as ISO 50001. At their most basic level, energy savings are determined through a process of accounting for baseline and reporting period energy consumption followed by a calculation of energy savings as the difference in the levels of energy consumption between the two periods. The determination of industrial facility-wide energy savings can be undertaken in a wide variety of ways and in relation to energy performance improvement, energy savings can be expressed as any number of energy performance indicators (EnPIs). Energy savings values will vary depending upon if an absolute, intensity, or regression basis of calculation is selected for use. The use of one of the three basis of energy savings calculation will alter the relevance, meaning, and comparability of the resulting energy savings values To increase consistency in the determination of energy savings values, standards such as the International Performance Measurement and Verification Protocol (IPMVP), ISO 17747 – Determination of Energy Savings in Organization, and the U.S. Department of Energy (U.S. DOE) Superior Energy Performance (SEP) program Measurement and Verification Protocol (SEP M&V Protocol) have been published. Industrial facilities in the United States, Mexico, and Canada are certified to the U.S. DOE SEP program after becoming ISO 50001 certified and verification by a third party of calculated energy savings per the SEP M&V Protocol. This paper discusses some of the different meanings energy savings values will have when calculated by using the three different bases. Additionally, data from five SEP certified industrial facilities are used to calculate energy savings values using the three bases and compared as energy performance improvement percentage (EPI %) values. Discussion of why a large degree in variation in EPI % values are seen for any given set of data is provided. Ultimately, while each energy saving calculation basis has merit and can be used appropriately in its own context, the regression basis is shown to best translates energy savings values into contextualized energy performance improvement values by conveying comparable information regarding operational and behavioural improvements not otherwise observable with the absolute or intensity bases.

Therkelsen, Peter↗

Final Technical Report

The Georgia Institute of Technology’s Industrial Assessment Center (GT IAC) has a long history working on the IAC program with over 30 years of experience in meeting the IAC program’s goals in a very effective manner since beginning participation in the IAC program’s predecessor, the EADC, in 1977. During the last four year contract period, October 1, 2002 through September 31, 2006, the GT IAC continued this work with the assessments of eighty nine (89) industrial facilities. These assessments resulted in the reported implemented savings of forty eight thousand (48,000,000) kWh of electricity and seven hundred and fifty thousand (750,000) MMBtu of natural gas. The total calculated cost savings from the recommendations implemented was five and a half million dollars ($5,500,000). These savings reoccur annually. However, this cost savings is the total of various recommendations that were calculated during 2002 to 2006. During this time period, energy prices were almost always lower than current energy prices. If you adjust the cost savings number to account for current energy prices, the cost savings would exceed nine million dollars ($9,000,000) reoccurring annually. Beyond the reduction of industrial energy consumption and the cost savings benefit, education has also been an important element of this Center’s work. Primarily this entailed both formal and on the job training of this Center’s student employees. Over the four year time frame, this Center has had fifteen different student employees work for this Center. This Center has also instructed a graduate level senior mechanical engineering class that allowed senior engineering students to conduct IAC assessments under the supervision of IAC staff. This class exposed over one hundred students to industrial energy consumption and energy efficiency. In addition to educating students, the education of plant personnel has also been an important element for this Center. It is believed that this Center has made effective use of IAC program resources by reducing industrial plant energy consumption and cost by helping them become more energy efficient. In turn, this has helped make domestic industry more competitive. This Center has also helped by introducing the next generation of engineers to energy efficiency in the industrial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗