Publications and source records attributed to Lin, Y.-S..

CRRES microelectronic test chip orbital data. II

Data from a MOSFET matrix on two JPL (CIT Jet Propulsion Laboratory) CRRES (Combined Release and Radiation Effects Satellite) chips, each behind different amounts of shielding, are presented. Space damage factors are nearly identical to ground test values for pMOSFETs. The results from neighboring rows of MOSFETs show similar radiation degradation. The SRD (Space Radiation Dosimeter) is used to measure the total dose accumulated by the JPL chips. A parameter extraction algorithm that does not underestimate threshold voltage shifts is used. Temperature effects are removed from the MOSFET data.

Soli, G. A.

CRRES microelectronic test chip

The JPL CRRES chip was designed and fabricated in 1985 and included in the CRRES MEP. MOSFET Matrix results show the effect of shielding on radiation-induced MOSFET threshold voltage shifts and channel mobility degradation. Shielded (middle board) MOSFETs have a threshold-voltage damage factor that is approximately three orders of magnitude smaller than would be estimated from Co-60 ground tests. Unshielded (outer board) MOSFETs have a threshold-voltage damage factor that would be estimated from Co-60 ground tests. Temperature swings as large as 23 C with a 22.5 orbit periodicity affected the MOSFET data and were removed from the data in order to reveal the radiation effects. This experiment demonstrated the feasibility of characterizing MOSFETs in a matrix, thus reducing the complexity and mass of the experiment.

Lin, Y.-S.

Test chips and ASIC qualification

A test chip set being developed to aid in the qualification of spaceborne Application Specific Integrated Circuits (ASICs) is described. The chip set consists of a process monitor for process parameter verification, a fault chip for yield analysis, a reliability chip for ASIC failure rate analysis, and total ionizing dose and single event upset chips for radiation effect analysis. The test structures contained in these chips are discussed along with representative test results.

Buehler, M. G.

End-of-fabrication CMOS process monitor

A set of test 'modules' for verifying the quality of a complementary metal oxide semiconductor (CMOS) process at the end of the wafer fabrication is documented. By electrical testing of specific structures, over thirty parameters are collected characterizing interconnects, dielectrics, contacts, transistors, and inverters. Each test module contains a specification of its purpose, the layout of the test structure, the test procedures, the data reduction algorithms, and exemplary results obtained from 3-, 2-, or 1.6-micrometer CMOS/bulk processes. The document is intended to establish standard process qualification procedures for Application Specific Integrated Circuits (ASIC's).

Buehler, M. G.

Radiation dependence of inverter propagation delay from timing sampler measurements

A timing sampler consisting of 14 four-stage inverter-pair chains with different load capacitances was fabricated in 1.6-micron n-well CMOS and irradiated with cobalt-60 at 10 rad(Si)/s. For this CMOS process the measured results indicate that the rising delay increases by about 2.2 ns/Mrad(Si) and the falling delay increase is very small, i.e., less than 300 ps/Mrad(Si). The amount of radiation-induced delay depends on the size of the load capacitance. The maximum value observed for this effect was 5.65 ns/pF-Mrad(Si). Using a sensitivity analysis, the sensitivity of the rising delay to radiation can be explained by a simple timing model and the radiation sensitivity of dc MOSFET parameters. This same approach could not explain the insensitivity of the falling delay to radiation. This may be due to a failure of the timing model and/or trapping effects.

Buehler, M. G.

Product assurance technology for procuring reliable, radiation-hard, custom LSI/VLSI electronics

Advanced measurement methods using microelectronic test chips are described. These chips are intended to be used in acquiring the data needed to qualify Application Specific Integrated Circuits (ASIC's) for space use. Efforts were focused on developing the technology for obtaining custom IC's from CMOS/bulk silicon foundries. A series of test chips were developed: a parametric test strip, a fault chip, a set of reliability chips, and the CRRES (Combined Release and Radiation Effects Satellite) chip, a test circuit for monitoring space radiation effects. The technical accomplishments of the effort include: (1) development of a fault chip that contains a set of test structures used to evaluate the density of various process-induced defects; (2) development of new test structures and testing techniques for measuring gate-oxide capacitance, gate-overlap capacitance, and propagation delay; (3) development of a set of reliability chips that are used to evaluate failure mechanisms in CMOS/bulk: interconnect and contact electromigration and time-dependent dielectric breakdown; (4) development of MOSFET parameter extraction procedures for evaluating subthreshold characteristics; (5) evaluation of test chips and test strips on the second CRRES wafer run; (6) two dedicated fabrication runs for the CRRES chip flight parts; and (7) publication of two papers: one on the split-cross bridge resistor and another on asymmetrical SRAM (static random access memory) cells for single-event upset analysis.

Buehler, M. G.

A CMOS matrix for extracting MOSFET parameters before and after irradiation

An addressable matrix of 16 n- and 16 p-MOSFETs was designed to extract the dc MOSFET parameters for all dc gate bias conditions before and after irradiation. The matrix contains four sets of MOSFETs, each with four different geometries that can be biased independently. Thus the worst-case bias scenarios can be determined. The MOSFET matrix was fabricated at a silicon foundry using a radiation-soft CMOS p-well LOCOS process. Co-60 irradiation results for the n-MOSFETs showed a threshold-voltage shift of -3 mV/krad(Si), whereas the p-MOSFETs showed a shift of 21 mV/krad(Si). The worst-case threshold-voltage shift occurred for the n-MOSFETs, with a gate bias of 5 V during the anneal. For the p-MOSFETs, biasing did not affect the shift in the threshold voltage. A parasitic MOSFET dominated the leakage of the n-MOSFET biased with 5 V on the gate during irradiation. Co-60 test results for other parameters are also presented.

Blaes, B. R.

Comparison of results from simple expressions for MOSFET parameter extraction

In this paper results are compared from a parameter extraction procedure applied to the linear, saturation, and subthreshold regions for enhancement-mode MOSFETs fabricated in a 3-micron CMOS process. The results indicate that the extracted parameters differ significantly depending on the extraction algorithm and the distribution of I-V data points. It was observed that KP values vary by 30 percent, VT values differ by 50 mV, and Delta L values differ by 1 micron. Thus for acceptance of wafers from foundries and for modeling purposes, the extraction method and data point distribution must be specified. In this paper measurement and extraction procedures that will allow a consistent evaluation of measured parameters are discussed.

Buehler, M. G.

Propagation delay measurements from a timing sampler intended for use in space

A 3-micron CMOS timing sampler is described which is a test circuit designed into the Jet Propulsion Labs' CRRES chip to be flown on the Combined Release and Radiation Effects Satellite (CRRES). The timing sampler consists of 64 inverter-pair stages with sampling latches and decoder circuitry. The sampler is used to measure inverter-pair propagation delays, which are nominally 2.5 ns, with a resolution of 100 ps. A simple model was developed to explain the radiation-induced inverter-pair delay shifts in terms of radiation-induced MOSFET threshold-voltage shifts and effective modal capacitances. The magnitude of the shift in pair delay with radiation was estimated at the point where the n-MOSFET threshold voltage became zero. For a 0.7-V-threshold shift, the pair delay increased from its preradiation value by 360 ps for a rising step input and decreased by 190 ps for a falling step input.

Blaes, B. R.