Integrated magnetic components for distributed power conversion
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Lieneweg, U..
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The NASA roadmap outlining future deep space missions to Europa and other outer planetary destinations calls for continued reductions in the mass and volume of the spacecraft avionics. Spacecraft power electronics, including the power switches and converters, remain difficult to miniaturize due to the need for large numbers of discrete passive components such as resistors, capacitors, inductors and transformers. As part of the System-on-a-chip program at the Center for Integrated Space Microsystems and at the University of Arkansas, we are working to develop integrated or embedded passive components geared specifically for use in power management and distribution (PMAD) in future avionics over the next five to ten years. This will not only enable a scaling down of the power subsystems, but will make possible new architectures such as "distributed" PMAD. Additional information is contained in the original extended abstract.
This paper will focus on the development of microinductors for a 1-10 MHz integrated dc-dc converter for space applications.
Explore the source record for details and available documents.
In the present work, the hot-carrier degradation of transistors fabricated by a 0.25- mu m FD SOI CMOS process was investigated.
The prospect of a monolithic, integrated dc-dc converter has spurred the development in on-chip inductors using conventional silicon compatible fabrication techniques.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The sub-orbital rocket mission was a collaborative project between the University of New Hampshire, Cornell University, and the Jet Propulsion Laboratory (JPL) to study filamentation phenomena in the northern Auroral zone. The Enstrophy mission test flies the JPL Free-Flying Magnetometer (FFM) concept. The FFM technology development task has been funded by NASA develop miniaturized, low-power, integrated "sensorcrafts". JPL's role was to design, integrate, test, and deliver four FFMs for deployment from the sounding rocket, allowing a unique determination of curl-B. This provides a direct measurement of magnetic-field-aligned current density along the rocket trajectory. A miniaturized three-axis fluxgate magnetometer was integrated with a 4-channel 22-bit sigma-delta Analog to Digital Converter (ADC), four temperature sensors, digital control electronics, seven (Li-SOCl2) batteries, two (4 deg x 170 deg field of view) sun-sensors, a fan-shaped-beam laser diode beacon, a (16 MHz) stable Temperature Compensated Crystal Oscillator (TCXO) clock, Radio Frequency (RF) communication subsystem, and an antenna for approximately 15 minutes of operation where data was collected continuously and transmitted in three (3) bursts (approximately 26 seconds each) to ground station antennas at Poker Flat, Alaska. FFMs were stowed within two trays onboard the rocket during the rocket launch and were released simultaneously using the spinning action of the rocket at approximately 300 km altitude (approximately 100 sec. into the flight). FFMs were deployed with spin rate of approximately 17 Hz and approximately 3 m/sec linear velocity with respect to the rocket. For testing purposes while the rocket was in the launch pad and during flight prior to release of FFMs from the rocket, commands (such as "power on", "test", "flight", "power off', and clock "Reset" signal) were transmitted via a infrared Light Emitting Diode to an infrared detector in the FFM. Special attention was paid to low magnetic signature electronic design and choice of materials in packaging. The miniaturized fluxgate magnetometers had a range of 1-60000 nT with 0.1% full-scale linearity. The frequency range of interest for magnetic measurement was 10 mHz - 50 Hz. Digital data from the magnetometer's three axes were placed in a 4MB Static Random Access Memory (SRAM) in data packages (frames) formatted together with time tags and frame ID. After a specified time was elapsed, the data were Viterbi encoded and transmitted at a rate of 100 kbps (BPSK). Each of the four FFMs transmitted at different frequency. These carrier frequencies were in the range of 2200-2300 MHz. The antenna was a single patch on a high dielectric constant substrate covering one end-plate of the hockey-puck-sized unit. The local clocks aboard the FFMs were reset at the start of the mission and stayed synchronized within 3 msec during the mission. Position of each FFM with respect to the rocket is calculated by the knowledge of its release velocity (measured at exit point of the FFM launcher tract) providing an accuracy of 1 m over the maximum range of 3 km. Spatial and temporal nature of observants can be separated to within 3 m in space or 3 msec time interval.
Explore the source record for details and available documents.
A Free-Flying Magnetometer (FFM) is an autonomous spin-stabilized sensorcraft that measures vector magentic field at dc and low frequencies by means of a 3-axis magnetometer.
In this paper a method for achieving integrated power electronics is discussed. Furture spacecraft are projected to feature high levels of intergration at the system level particularly in areas not typically associated with an integrated approach.
The sub-orbital rocket mission was a collaborative project between the University of New Hampshire, Cornell University, and the Jet Propulsion Laboratory to study filamentation phenomenon in the northern Auroral zone.
Data storage systems based on vertical Bloch lines have been fabricated in 2 um bubble garnet material. The input/output line was fully operational, and experiments in reading and writing showed an encouraging correlation between input and output.
It was attempted to assess the reliability of DRAMs at the package level.