A WRF-Chem Analysis of Flash Rates, Lightning-NOx Production and Subsequent Trace Gas Chemistry of the 29-30 May 2012 Convective Event in Oklahoma During DC3

The Deep Convective Clouds and Chemistry (DC3) field campaign in 2012 provided a plethora of aircraft and ground-based observations (e.g., trace gases, lightning and radar) to study deep convective storms, their convective transport of trace gases, and associated lightning occurrence and production of nitrogen oxides (NOx). This is a continuation of previous work, which compared lightning observations (Oklahoma Lightning Mapping Array and National Lightning Detection Network) with flashes generated by various flash rate parameterization schemes (FRPSs) from the literature in a Weather Research and Forecasting Chemistry (WRF-Chem) model simulation of the 29-30 May 2012 Oklahoma thunderstorm. Based on the Oklahoma radar observations and Lightning Mapping Array data, new FRPSs are being generated and incorporated into the model. The focus of this analysis is on estimating the amount of lightning-generated nitrogen oxides (LNOx) produced per flash in this storm through a series of model simulations using different production per flash assumptions and comparisons with DC3 aircraft anvil observations. The result of this analysis will be compared with previously studied mid-latitude storms. Additional model simulations are conducted to investigate the upper troposphere transport, distribution, and chemistry of the LNOx plume during the 24 hours following the convective event to investigate ozone production. These model-simulated mixing ratios are compared against the aircraft observations made on 30 May over the southern Appalachians.

Cummings, Kristin A.↗

MO-F-16A-05: Spot-Scanning Proton Therapy Patient-Specific Quality Assurance: Our Methodology and Results From 295 Treatment Plans

Purpose: To report on the patient-specific quality assurance (PSQA) results for 295 spot-scanning proton therapy treatment plans from the MD Anderson PTC-Houston. We show how the results differed by treatment site and how they were affected by the treatment plan optimization method and by a range shifter in the treatment field. We also discuss some causes of PSQA problems. Methods: The PSQA procedure, which is designed to verify both the accuracy of the treatment planning system's (Eclipse™ v8.9) dose calculations and the dose delivery of the Hitachi PROBEAT synchrotron, consists of (1) an end-to-end test in which the beam is delivered and measured at the prescribed gantry angle, and (2) additional dose plane measurements made from gantry angle 270°. HPlusQA™ software automatically performs the gamma analysis with criteria 3% (dose tolerance), 3 mm (distance-to-agreement, DTA) and 2%, 2 mm. Passing is defined as at least 90% of the pixels having a gamma score less than 1. Results: The PSQA gamma passing rate was 96.2% for 3%, 3 mm, and 85.3% for 2%, 2 mm. The rate depended on the treatment site. For example, the 3%, 3 mm passing rate was 95% for head and neck plans, vs 100% for prostate plans. The passing rates of multi- vs. single-field optimization plans did not significantly differ. However, the rate for fields with range shifters was 94.8±0.6%, vs 99.0±0.6% for those without (p = 0.002). Longitudinal dose gradients caused most of the low scores. Overestimation of the calculated dose proximal to the spread-out Bragg peak (SOBP) caused many of the others. Conclusion: The planned and delivered doses consistently agreed within tolerance levels. Minor dose modeling deficiencies remain proximal to the SOBP. The 3% dose tolerance, 3 mm DTA, with 90% pixel passing rate is a reasonable action level for 2D gamma comparisons.

60 APPLIED LIFE SCIENCES↗

TH-C-BRD-07: Minimizing Dose Uncertainty for Spot Scanning Beam Proton Therapy of Moving Tumor with Optimization of Delivery Sequence

Purpose: Intensity modulated proton therapy (IMPT) has been shown to be able to reduce dose to normal tissue compared to intensity modulated photon radio-therapy (IMRT), and has been implemented for selected lung cancer patients. However, respiratory motion-induced dose uncertainty remain one of the major concerns for the radiotherapy of lung cancer, and the utility of IMPT for lung patients was limited because of the proton dose uncertainty induced by motion. Strategies such as repainting and tumor tracking have been proposed and studied but repainting could result in unacceptable long delivery time and tracking is not yet clinically available. We propose a novel delivery strategy for spot scanning proton beam therapy. Method: The effective number of delivery (END) for each spot position in a treatment plan was calculated based on the parameters of the delivery system, including time required for each spot, spot size and energy. The dose uncertainty was then calculated with an analytical formula. The spot delivery sequence was optimized to maximize END and minimize the dose uncertainty. 2D Measurements with a detector array on a 1D moving platform were performed to validate the calculated results. Results: 143 2D measurements on a moving platform were performed for different delivery sequences of a single layer uniform pattern. The measured dose uncertainty is a strong function of the delivery sequence, the worst delivery sequence results in dose error up to 70% while the optimized delivery sequence results in dose error of <5%. END vs. measured dose uncertainty follows the analytical formula. Conclusion: With optimized delivery sequence, it is feasible to minimize the dose uncertainty due to motion in spot scanning proton therapy.

60 APPLIED LIFE SCIENCES↗

TH-C-BRD-12: Robust Intensity Modulated Proton Therapy Plan Can Eliminate Junction Shifts for Craniospinal Irradiation

Purpose: The passive scattering proton therapy (PSPT) technique is the commonly used radiotherapy technique for craniospinal irradiation (CSI). However, PSPT involves many numbers of junction shifts applied over the course of treatment to reduce the cold and hot regions caused by field mismatching. In this work, we introduced a robust planning approach to develop an optimal and clinical efficient techniques for CSI using intensity modulated proton therapy (IMPT) so that junction shifts can essentially be eliminated. Methods: The intra-fractional uncertainty, in which two overlapping fields shift in the opposite directions along the craniospinal axis, are incorporated into the robust optimization algorithm. Treatment plans with junction sizes 3,5,10,15,20,25 cm were designed and compared with the plan designed using the non-robust optimization. Robustness of the plans were evaluated based on dose profiles along the craniospinal axis for the plans applying 3 mm intra-fractional shift. The dose intra-fraction variations (DIV) at the junction are used to evaluate the robustness of the plans. Results: The DIVs are 7.9%, 6.3%, 5.0%, 3.8%, 2.8% and 2.2%, for the robustly optimized plans with junction sizes 3,5,10,15,20,25 cm. The DIV are 10% for the non-robustly optimized plans with junction size 25 cm. The dose profiles along the craniospinal axis exhibit gradual and tapered dose distribution. Using DIVs less than 5% as maximum acceptable intrafractional variation, the overlapping region can be reduced to 10 cm, leading to potential reduced number of the fields. The DIVs are less than 5% for 5 mm intra-fractional shifts with junction size 25 cm, leading to potential no-junction-shift for CSI using IMPT. Conclusion: This work is the first report of the robust optimization on CSI based on IMPT. We demonstrate that robust optimization can lead to much efficient carniospinal irradiation by eliminating the junction shifts.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-08: GPU-Monte Carlo Based Fast IMRT Plan Optimization

Purpose: Intensity-modulated radiation treatment (IMRT) plan optimization needs pre-calculated beamlet dose distribution. Pencil-beam or superposition/convolution type algorithms are typically used because of high computation speed. However, inaccurate beamlet dose distributions, particularly in cases with high levels of inhomogeneity, may mislead optimization, hindering the resulting plan quality. It is desire to use Monte Carlo (MC) methods for beamlet dose calculations. Yet, the long computational time from repeated dose calculations for a number of beamlets prevents this application. It is our objective to integrate a GPU-based MC dose engine in lung IMRT optimization using a novel two-steps workflow. Methods: A GPU-based MC code gDPM is used. Each particle is tagged with an index of a beamlet where the source particle is from. Deposit dose are stored separately for beamlets based on the index. Due to limited GPU memory size, a pyramid space is allocated for each beamlet, and dose outside the space is neglected. A two-steps optimization workflow is proposed for fast MC-based optimization. At first step, rough beamlet dose calculations is conducted with only a small number of particles per beamlet. Plan optimization is followed to get an approximated fluence map. In the second step, more accurate beamlet doses are calculated, where sampled number of particles for a beamlet is proportional to the intensity determined previously. A second-round optimization is conducted, yielding the final Result. Results: For a lung case with 5317 beamlets, 10{sup 5} particles per beamlet in the first round, and 10{sup 8} particles per beam in the second round are enough to get a good plan quality. The total simulation time is 96.4 sec. Conclusion: A fast GPU-based MC dose calculation method along with a novel two-step optimization workflow are developed. The high efficiency allows the use of MC for IMRT optimizations.

60 APPLIED LIFE SCIENCES↗

SU-E-P-06: A Novel Hybrid Planning Approach to Allow More Patients Benefited by the Intensity Modulated Proton Therapy

Purpose: We report a hybrid scattering and scanning beam delivery approach, termed as (HimpsPT), which demonstrated that majority IMPT delivery can be potentially replaced with hybrid IMPT and PSPT delivery with similar or better plan quality. Methods: Three representative clinical cases, including head and neck (HN), skull base chordoma (CNS) and lung cancer, treated in MDACC Proton Therapy Center with IMPT were retrospectively redesigned using HimpsPT. The PSPT plans are designed with the same prescriptions as those of IMPT plans. The whole treatment can be delivered by either alternating or sequential PSPT and IMPT delivery. The dosimetric data and dose distributions of HimpsPT plans are compared with those of IMPT plans. We also performed a worst-case robust analysis for all plans. Results: The target coverages for all cases are comparable. For the HN case, the mean dose of esophagus larynx, left parotid and right submandibular, oral cavity V20, the max dose of cord is 18.0, 36.1, 23.6, 47.2, 0.1, 31.7 Gy in HimpsPT plan, and 25.5, 33.8, 24.9, 49.1, 0.2, 33.8 Gy in IMPT plan. For the lung case, the lung V5, V20, V30, mean lung dose, heart V40, esophagus V70, cord maximum dose are 50.5%, 37.0%, 31.7%, 21.3 Gy, 7.2%, 4.9%, 35.5 Gy in HimpsPT plan, and 55.4%, 36.7%, 30.1%, 21.3 Gy, 7.7%, 8.4%, 36.8Gy in IMPT plans. For the CNS case, brainstem maximum dose is 50.5 Gy in HimpsPT plan and 55.4 Gy in IMPT plan due to sharp penumbra offered by the aperture of the PSPT plan in HimpsPT technique. Conclusion: For majority disease sites, the dosimetric advantage of IMPT technique can be achieved by the hybrid PSPT and IMPT technique, which enables the centers equipped with both scattering and scanning beam facilities to treat more patients which can be benefited by the scanning beam.

60 APPLIED LIFE SCIENCES↗

SU-E-J-79: Internal Tumor Volume Motion and Volume Size Assessment Using 4D CT Lung Data

Purpose: To assess internal tumor volume change through breathing cycle and associated tumor motion using the 4DCT data. Methods: Respiration induced volume change through breathing cycle and associated motion was analyzed for nine patients that were scanned during the different respiratory phases. The examined datasets were the maximum and average intensity projections (MIP and AIP) and the 10 phases of the respiratory cycle. The internal target volume (ITV) was delineated on each of the phases and the planning target volume (PTV) was then created by adding setup margins to the ITV. Tumor motion through the phases was assessed using the acquired 4DCT dataset, which was then used to determine if the margins used for the ITV creation successfully encompassed the tumor in three dimensions. Results: Results showed that GTV motion along the superior inferior axes was the largest in all the cases independent of the tumor location and/or size or the use of abdomen compression. The extent of the tumor motion was found to be connected with the size of the GTV. The smallest GTVs exhibited largest motion vector independent of the tumor location. The motion vector size varied through the phases depending on the tumor size and location and it was smallest for phases 20 and 30. The smaller the volume of the delineated GTV, the greater its volume difference through the different respiratory phases was. The average GTV volume change was largest for the phases 60 and 70. Conclusion: Even if GTV is delineated using both AIP and MIP datasets, its motion extent will exceed the used margins especially for the very small GTV volumes. When the GTV size is less than 10 cc it is recommended to use fusion of the GTVs through all the phases to create the planning ITV.

60 APPLIED LIFE SCIENCES↗

SU-E-J-122: Detecting Treatment-Induced Metabolic Abnormalities in Craniopharyngioma Patients Undergoing Surgery and Proton Therapy

Purpose: To identify treatment-induced defects in the brain of children with craniopharyngioma receiving surgery and proton therapy using fluorodeoxyglucose positron emission tomography (FDG PET). Methods: Forty seven patients were enrolled on a clinical trial for craniopharyngioma with serial imaging and functional evaluations. Proton therapy was delivered using the double-scattered beams with a prescribed dose of 54 Cobalt Gray Equivalent. FDG tracer uptake in each of 63 anatomical regions was computed after warping PET images to a 3D reference template in Talairach coordinates. Regional uptake was deemed significantly low or high if exceeding two standard deviations of normal population from the mean. For establishing the normal ranges, 132 children aged 1–20 years with noncentral nervous system related diseases and normal-appearing cerebral PET scans were analyzed. Age- and gender-dependent regional uptake models were developed by linear regression and confidence intervals were calculated. Results: Most common PET abnormality before proton therapy was significantly low uptake in the frontal lobe, the occipital lobe (particularly in cuneus), the medial and ventral temporal lobe, cingulate gyrus, caudate nuclei, and thalamus. They were related to injury from surgical corridors, tumor mass effect, insertion of a ventricular catheter, and the placement of an Ommaya reservoir. Surprisingly a significantly high uptake was observed in temporal gyri and the parietal lobe. In 13 patients who already completed 18-month PET scans, metabolic abnormalities improved in 11 patients from baseline. One patient had persistent abnormalities. Only one revealed new uptake abnormalities in thalamus, brainstem, cerebellum, and insula. Conclusion: Postoperative FDG PET of craniopharyngioma patients revealed metabolic abnormalities in specific regions of the brain. Proton therapy did not appear to exacerbate these surgery- and tumor-induced defects. In patients with persistent and new abnormalities, continued investigation on clinical symptoms and cognitive outcomes is ongoing to establish the association and predictive values of metabolic imaging.

60 APPLIED LIFE SCIENCES↗

SU-E-J-133: Evaluation of Inter- and Intra-Fractional Pancreas Tumor Residual Motions with Abdominal Compression

Purpose: Abdominal compression (AC) has been widely used to reduce pancreas motion due to respiration for pancreatic cancer patients undergoing stereotactic body radiotherapy (SBRT). However, the inter-fractional and intra-fractional patient motions may degrade the treatment. The purpose of this work is to study daily CBCT projections and 4DCT to evaluate the inter-fractional and intra-fractional pancreatic motions. Methods: As a standard of care at our institution, 4D CT scan was performed for treatment planning. At least two CBCT scans were performed for daily treatment. Retrospective studies were performed on patients with implanted internal fiducial markers or surgical clips. The initial motion pattern was obtained by extracting marker positions on every phase of 4D CT images. Daily motions were presented by marker positions on CBCT scan projection images. An adaptive threshold segmentation algorithm was used to extract maker positions. Both marker average positions and motion ranges were compared among three sets of scans, 4D CT, positioning CBCT, and conformal CBCT, for inter-fractional and intra-fractional motion variations. Results: Data from four pancreatic cancer patients were analyzed. These patients had three fiducial markers implanted. All patients were treated by an Elekta Synergy with single fraction SBRT. CBCT projections were acquired by XVI. Markers were successfully detected on most of the projection images. The inter-fractional changes were determined by 4D CT and the first CBCT while the intra-fractional changes were determined by multiple CBCT scans. It is found that the average motion range variations are within 2 mm, however, the average marker positions may drift by 6.5 mm. Conclusion: The patients respiratory motion variation for pancreas SBRT with AC was evaluated by detecting markers from CBCT projections and 4DCT, both the inter-fraction and intra-fraction motion range change is small but the drift of marker positions may be comparable to motion ranges.

60 APPLIED LIFE SCIENCES↗

SU-E-T-49: Automatic Beam Angle Determination for Lung IMRT Planning Using a Beam Configuration Atlas

Purpose: To present a technique to automatically determine beam angle configurations for lung IMRT planning based on the patient-specific anatomy and tumor geometry. Methods: The relationship between individual patient anatomy and proper beam configurations was learned from high quality clinical plans in three steps. First, a beam configuration atlas was obtained by classifying 60 lung IMRT plans into 6 beam configuration clusters based on a dissimilarity measure defined between different beam configurations. A beam configuration template was extracted from each cluster to form an atlas. Second, a beam efficiency index map (EI map) was constructed to characterize the geometry of the tumor relative to the lungs, the body and other OARs along each candidate beam direction. Finally, the EI maps of the clinical cases and the cluster assignments of their beam configurations were paired to train a Bayesian classification model. This technique was validated by leave-one-out cross validation with 16 cases randomly selected from the original dataset. An IMRT plan (autobeam plan) for each test case was generated using the beam configuration template according to the cluster assignment given by the model and was compared with the corresponding clinical plan. Results: The dosimetric parameters (mean±S.D. in percentage of prescription dose) in the auto-beam plans and in the clinical plans, respectively, and the p-values by a paired ttest (in parenthesis) are: lung Dmean: 16.3±9.3, 18.6±7.4 (0.48), esophagus Dmean: 28.4±18, 30.7±19.3 (0.02), Heart Dmean: 21.5±17.5,21.1±17.2 (0.76), Spinal Cord D2%: 48±23, 51.2±21.8 (0.01), PTV dose homogeneity (D2%–D99%): 22±27.4, 20.4±12.8 (0.10).The dose reductions by the autobeam plans in esophagus Dmean and cord D02 are statistically significant but the differences (<4%) may not be clinically significant. The other dosimetric parameters are not statistically different. Conclusion: Plans generated by the automatic beam angle determination method can achieve dosimetric quality equivalent to that of clinical plans. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.

60 APPLIED LIFE SCIENCES↗

SU-E-T-174: Evaluation of the Optimal Intensity Modulated Radiation Therapy Plans Done On the Maximum and Average Intensity Projection CTs

Purpose: To determine the difference in coverage between plans done on average intensity projection and maximum intensity projection CT data sets for lung patients and to establish correlations between different factors influencing the coverage. Methods: For six lung cancer patients, 10 phases of equal duration through the respiratory cycle, the maximum and average intensity projections (MIP and AIP) from their 4DCT datasets were obtained. MIP and AIP datasets had three GTVs delineated (GTVaip — delineated on AIP, GTVmip — delineated on MIP and GTVfus — delineated on each of the 10 phases and summed up). From the each GTV, planning target volumes (PTV) were then created by adding additional margins. For each of the PTVs an IMRT plan was developed on the AIP dataset. The plans were then copied to the MIP data set and were recalculated. Results: The effective depths in AIP cases were significantly smaller than in MIP (p < 0.001). The Pearson correlation coefficient of r = 0.839 indicates strong degree of positive linear relationship between the average percentage difference in effective depths and average PTV coverage on the MIP data set. The V2 0 Gy of involved lung depends on the PTV coverage. The relationship between PTVaip mean CT number difference and PTVaip coverage on MIP data set gives r = 0.830. When the plans are produced on MIP and copied to AIP, r equals −0.756. Conclusion: The correlation between the AIP and MIP data sets indicates that the selection of the data set for developing the treatment plan affects the final outcome (cases with high average percentage difference in effective depths between AIP and MIP should be calculated on AIP). The percentage of the lung volume receiving higher dose depends on how well PTV is covered, regardless of on which set plan is done.

60 APPLIED LIFE SCIENCES↗

SU-E-T-452: Impact of Respiratory Motion On Robustly-Optimized Intensity-Modulated Proton Therapy to Treat Lung Cancers

Purpose: We compared conventionally optimized intensity-modulated proton therapy (IMPT) treatment plans against the worst-case robustly optimized treatment plans for lung cancer. The comparison of the two IMPT optimization strategies focused on the resulting plans' ability to retain dose objectives under the influence of patient set-up, inherent proton range uncertainty, and dose perturbation caused by respiratory motion. Methods: For each of the 9 lung cancer cases two treatment plans were created accounting for treatment uncertainties in two different ways: the first used the conventional Method: delivery of prescribed dose to the planning target volume (PTV) that is geometrically expanded from the internal target volume (ITV). The second employed the worst-case robust optimization scheme that addressed set-up and range uncertainties through beamlet optimization. The plan optimality and plan robustness were calculated and compared. Furthermore, the effects on dose distributions of the changes in patient anatomy due to respiratory motion was investigated for both strategies by comparing the corresponding plan evaluation metrics at the end-inspiration and end-expiration phase and absolute differences between these phases. The mean plan evaluation metrics of the two groups were compared using two-sided paired t-tests. Results: Without respiratory motion considered, we affirmed that worst-case robust optimization is superior to PTV-based conventional optimization in terms of plan robustness and optimality. With respiratory motion considered, robust optimization still leads to more robust dose distributions to respiratory motion for targets and comparable or even better plan optimality [D95% ITV: 96.6% versus 96.1% (p=0.26), D5% - D95% ITV: 10.0% versus 12.3% (p=0.082), D1% spinal cord: 31.8% versus 36.5% (p =0.035)]. Conclusion: Worst-case robust optimization led to superior solutions for lung IMPT. Despite of the fact that robust optimization did not explicitly account for respiratory motion it produced motion-resistant treatment plans. However, further research is needed to incorporate respiratory motion into IMPT robust optimization.

60 APPLIED LIFE SCIENCES↗

Measurement of the inclusive semileptonic branching fraction B ( B s 0 → X - ℓ + ν ℓ ) at Belle

Here, we report a measurement of the inclusive semileptonic B s 0 branching fraction in a 121 fb - 1 data sample collected near the Υ ( 5 S ) resonance with the Belle detector at the KEKB asymmetric energy e + e - collider. Events with B s 0 ( * ) B ¯ s 0 ( * ) pairs are selected by reconstructing a tag side D s + and identifying a signal side lepton ℓ + ( ℓ = e , μ ) that is required to have the same-sign charge to ensure that both originate from different B s 0 mesons. The B s 0 → X - ℓ + ν ℓ branching fraction is extracted from the ratio of the measured yields of D s + mesons and D s + ℓ + pairs and the known production and branching fractions. The inclusive semileptonic branching fraction is measured to be [ 10.6 ± 0.5 ( stat ) ± 0.7 ( syst ) ] % .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗