Engineering Papers⌕ Search

Engineering topics

Li, Y

Publications and source records attributed to Li, Y.

At least 55 records · Page 3

SU-E-T-07: 4DCT Robust Optimization for Esophageal Cancer Using Intensity Modulated Proton Therapy

Purpose: To develop a 4DCT robust optimization method to reduce the dosimetric impact from respiratory motion in intensity modulated proton therapy (IMPT) for esophageal cancer. Methods: Four esophageal cancer patients were selected for this study. The different phases of CT from a set of 4DCT were incorporated into the worst-case dose distribution robust optimization algorithm. 4DCT robust treatment plans were designed and compared with the conventional non-robust plans. Result doses were calculated on the average and maximum inhale/exhale phases of 4DCT. Dose volume histogram (DVH) band graphic and ΔD95%, ΔD98%, ΔD5%, ΔD2% of CTV between different phases were used to evaluate the robustness of the plans. Results: Compare to the IMPT plans optimized using conventional methods, the 4DCT robust IMPT plans can achieve the same quality in nominal cases, while yield a better robustness to breathing motion. The mean ΔD95%, ΔD98%, ΔD5% and ΔD2% of CTV are 6%, 3.2%, 0.9% and 1% for the robustly optimized plans vs. 16.2%, 11.8%, 1.6% and 3.3% from the conventional non-robust plans. Conclusion: A 4DCT robust optimization method was proposed for esophageal cancer using IMPT. We demonstrate that the 4DCT robust optimization can mitigate the dose deviation caused by the diaphragm motion.

60 APPLIED LIFE SCIENCES↗

SU-E-T-175: Clinical Evaluations of Monte Carlo-Based Inverse Treatment Plan Optimization for Intensity Modulated Radiotherapy

Purpose: Pencil-beam or superposition-convolution type dose calculation algorithms are routinely used in inverse plan optimization for intensity modulated radiation therapy (IMRT). However, due to their limited accuracy in some challenging cases, e.g. lung, the resulting dose may lose its optimality after being recomputed using an accurate algorithm, e.g. Monte Carlo (MC). It is the objective of this study to evaluate the feasibility and advantages of a new method to include MC in the treatment planning process. Methods: We developed a scheme to iteratively perform MC-based beamlet dose calculations and plan optimization. In the MC stage, a GPU-based dose engine was used and the particle number sampled from a beamlet was proportional to its optimized fluence from the previous step. We tested this scheme in four lung cancer IMRT cases. For each case, the original plan dose, plan dose re-computed by MC, and dose optimized by our scheme were obtained. Clinically relevant dosimetric quantities in these three plans were compared. Results: Although the original plan achieved a satisfactory PDV dose coverage, after re-computing doses using MC method, it was found that the PTV D95% were reduced by 4.60%–6.67%. After re-optimizing these cases with our scheme, the PTV coverage was improved to the same level as in the original plan, while the critical OAR coverages were maintained to clinically acceptable levels. Regarding the computation time, it took on average 144 sec per case using only one GPU card, including both MC-based beamlet dose calculation and treatment plan optimization. Conclusion: The achieved dosimetric gains and high computational efficiency indicate the feasibility and advantages of the proposed MC-based IMRT optimization method. Comprehensive validations in more patient cases are in progress.

60 APPLIED LIFE SCIENCES↗

SU-E-T-283: Dose Perturbations Near Heterogeneity Junctions for Modulated-Scanning Protons

Purpose: To compare calculated and measured doses near heterogeneity junctions of tissue-substitute materials for modulated-scanning protons. Methods: Three heterogeneous phantoms were configured using slabs of various plastics to simulate lung, fat, soft-tissue (polystyrene), and bone with known relative linear stopping powers (RLSPs). Each phantom consisted of soft-tissue and a single heterogeneity of a 5 or 10 cm thickness of a non-soft-tissue material. CT images were loaded into a Syngo treatment planning system and each material contoured and assigned its RLSP. Planning target volumes (PTVs) were drawn such that a beam would partially traverse the heterogeneity and partially only soft-tissue. Lateral profiles were measured using EDR2 films at a minimum of six depths between the phantom surface and the depth corresponding to the beam range. Absolute doses were measured inside and distal to the PTV in all phantoms using either a parallel plate or thimble chamber. Additional dose measurements were made between two lung slabs. Results: Profiles measured by film generally agreed with calculations except for depths distal to lung and fat junctions. Measured lateral penumbras for depths at the distal junction of lung were found to be wider than calculated ones. Compared with calculated doses, measured doses in the PTVs were 5.19% and 2.51% lower for lung and fat respectively but for bone were 0.2% higher. Measured doses for depths distal to the PTV were up to 29.65% and 10.58% higher for lung and fat, respectively but 6.30% lower for bone. Conclusion: The low measured doses in the PTVs for lung and fat might be due to underestimation of lateral scattering of protons. The higher measured doses distal to the PTV for the lung and fat are a Result of a shortened calculated beam range whereas the higher dose distal to the bone junction is within uncertainties.

60 APPLIED LIFE SCIENCES↗

SU-E-T-435: Flattening Filter Free Beams for Head and Neck IMRT and VMAT Optimization

Purpose: To investigate if there is benefits of using flattening filter free (FFF) versus flattening filter (FF) beams during plan optimization for head and neck targets. Methods: Five head and neck cancer patients previously treated were selected for this study. Each plan was optimized for volumetric modulated arc therapy (VMAT) using 2 full arcs. Target volumes and the organs at risk (OAR) were outlined by the same physician. The prescription doses for each patient and the dose limits for each OAR were specified by the physician. For each patient four plans were created by varying the photon beam energy (6MV vs 10MV) and the use of FF or FFF. For each patient the prescription dose and OAR dose limits remained unchanged. Furthermore, the number of optimization iterations remained the same for each plan without user interference. The plans were compared using dose volume histograms, conformity and homogeneity indices. Results: Our results showed that the plans optimized with FF beams produced more homogeneous dose distributions in the PTV than the ones with FFF beams (0.92 vs. 0.86 and 0.92 vs.85 for 6MVFF, 6MVFFF, 10MVFF and 10MVFFF respectively). The conformity was better for FFF beams than for FF beams (1.26 vs. 1.20 and 1.27 vs. 1.21 for 6MVFF, 6MVFFF, 10MVFF and 10MVFFF respectively). The overall minimum, maximum and means doses were reduced for the FFF plans by approximately 4% to 6%. All FFF plans allowed more sparing of organs at risk by 7% to 9% on average. Only one 10MVFFF plan had a 1% higher dose than the respective 10MVFF for the spinal cord. Conclusion: The 6MVFFF and 10MVFFF beams illustrated the improvement of normal tissue sparing while achieving similar target dose distribution compared to 6MVFF and 10MVFF beams. Further investigation is required to determine the magnitude of improvement. case specific, fluence-based optimization improved both PTV and OAR dosimetry in 80% of cases.

60 APPLIED LIFE SCIENCES↗

SU-E-T-755: Timing Characteristics of Proton and Carbon Ion Treatments Using a Synchrotron and Modulated Scanning

Purpose: The time required to deliver a treatment impacts not only the number of patients that can be treated each day but also the accuracy of delivery due to potential movements of patient tissues. Both macroscopic and microscopic timing characteristics of a beam delivery system were studied to examine their impacts on patient treatments. Methods: 35 patients were treated during a clinical trial to demonstrate safety and efficacy of a Siemens Iontris system prior to receiving approval from the Chinese Food and Drug Administration. The system has a variable cycle time and can provide proton beams from 48 to 221 MeV/n and carbon ions from 86 to 430 MeV/n. A modulated scanning beam delivery technique is used where the beam remains stationary at each spot aiming location and is not turned off while the spot quickly moves from one aiming location to the next. The treatment log files for 28 of the trial patients were analyzed to determine several timing characteristics. Results: The average portal time per target dose was 172.5 s/Gy for protons and 150.7 s/Gy for carbon ions. The maximum delivery time for any portal was less than 300 s. The average dwell time per spot was 12 ms for protons and 3.0 ms for carbon ions. The number of aiming positions per energy layer varied from 1 to 258 for protons and 1 to 621 for carbon ions. The average spill time and cycle time per energy layer were 1.20 and 2.68 s for protons and 0.95 and 4.73 s for carbon ions respectively. For 3 of the patients, the beam was gated on and off to reduce the effects of respiration. Conclusion: For a typical target volume of 153 cc as used in this clinical trial, the portal delivery times were acceptable.

60 APPLIED LIFE SCIENCES↗

SU-E-T-795: Validations of Dose Calculation Accuracy of Acuros BV in High-Dose-Rate (HDR) Brachytherapy with a Shielded Cylinder Applicator Using Monte Carlo Simulation

Purpose: Acuros BV has become available to perform accurate dose calculations in high-dose-rate (HDR) brachytherapy with phantom heterogeneity considered by solving the Boltzmann transport equation. In this work, we performed validation studies regarding the dose calculation accuracy of Acuros BV in cases with a shielded cylinder applicator using Monte Carlo (MC) simulations. Methods: Fifteen cases were considered in our studies, covering five different diameters of the applicator and three different shielding degrees. For each case, a digital phantom was created in Varian BrachyVision with the cylinder applicator inserted in the middle of a large water phantom. A treatment plan with eight dwell positions was generated for these fifteen cases. Dose calculations were performed with Acuros BV. We then generated a voxelized phantom of the same geometry, and the materials were modeled according to the vendor’s specifications. MC dose calculations were then performed using our in-house developed fast MC dose engine for HDR brachytherapy (gBMC) on a GPU platform, which is able to simulate both photon transport and electron transport in a voxelized geometry. A phase-space file for the Ir-192 HDR source was used as a source model for MC simulations. Results: Satisfactory agreements between the dose distributions calculated by Acuros BV and those calculated by gBMC were observed in all cases. Quantitatively, we computed point-wise dose difference within the region that receives a dose higher than 10% of the reference dose, defined to be the dose at 5mm outward away from the applicator surface. The mean dose difference was ∼0.45%–0.51% and the 95-percentile maximum difference was ∼1.24%–1.47%. Conclusion: Acuros BV is able to accurately perform dose calculations in HDR brachytherapy with a shielded cylinder applicator.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-T-04: Utilization of Optical Dosimeter for Modulated Spot-Scanning Particle Beam

Purpose: To present the utilization of an optical dosimeter for modulated spot-scanning carbon-ion and proton beams during the acceptance test of Siemens IONTRIS system. Method and Materials: An optical dosimeter using phosphor scintillation was developed to map and interactively analyze the shapes and sizes of spots over 190 energies for ProTom modulated-scanning system. The dose response to proton had been characterized with proper pixel calibration at ProTom system. The dose response was further studied at 0.7 cm depths by uniform 8cm in-diameter fields of 424.89 MeV/u (E290) carbon-ions and 215.18MeV (E282) protons at IONTRIS system. The virtual source axial distances (vSAD) of carbonions and protons of IONTRIS system was investigated by measuring either variations of spot position or field size at five different locations to Isocenter. By measuring lateral profiles of uniform doses with varied thin-thicknesses of chest-board pattern and placing the scintillation plate at near to the distal edge, range variations at different off-axis-distances (rOAD) were examined. Relative accuracy and reproducibility of beam range were measured for three beam ranges with a ramping block at front of scintillation plate. Results: Similar dose response was observed for high energies of carbon ions and protons. Mean vSAD at X and Y axes were 744.1 cm and 807.4cm with deviation of 7.4cm and 7.7cm, respectively. Variation of rOAD was within 0.35 mm over 10cm for both protons and carbon ions. Accuracy of measuring relative distal range using the ramping block was 0.2mm. Measured range over repeated three times for each range were within 0.25mm at same room, and within 1.0mm between four rooms. Conclusions: The optical dosimeter could efficiently measure the virtual source distance. And, to measure small range variation at different off-axial locations, and for the relative beam range between rooms during acceptance test of a modulated spot-scanning particle system.

60 APPLIED LIFE SCIENCES↗

TU-EF-304-07: Monte Carlo-Based Inverse Treatment Plan Optimization for Intensity Modulated Proton Therapy

Purpose: Intensity-modulated proton therapy (IMPT) is increasingly used in proton therapy. For IMPT optimization, Monte Carlo (MC) is desired for spots dose calculations because of its high accuracy, especially in cases with a high level of heterogeneity. It is also preferred in biological optimization problems due to the capability of computing quantities related to biological effects. However, MC simulation is typically too slow to be used for this purpose. Although GPU-based MC engines have become available, the achieved efficiency is still not ideal. The purpose of this work is to develop a new optimization scheme to include GPU-based MC into IMPT. Methods: A conventional approach using MC in IMPT simply calls the MC dose engine repeatedly for each spot dose calculations. However, this is not the optimal approach, because of the unnecessary computations on some spots that turned out to have very small weights after solving the optimization problem. GPU-memory writing conflict occurring at a small beam size also reduces computational efficiency. To solve these problems, we developed a new framework that iteratively performs MC dose calculations and plan optimizations. At each dose calculation step, the particles were sampled from different spots altogether with Metropolis algorithm, such that the particle number is proportional to the latest optimized spot intensity. Simultaneously transporting particles from multiple spots also mitigated the memory writing conflict problem. Results: We have validated the proposed MC-based optimization schemes in one prostate case. The total computation time of our method was ∼5–6 min on one NVIDIA GPU card, including both spot dose calculation and plan optimization, whereas a conventional method naively using the same GPU-based MC engine were ∼3 times slower. Conclusion: A fast GPU-based MC dose calculation method along with a novel optimization workflow is developed. The high efficiency makes it attractive for clinical usages.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-11: Activity Distributions of Positron-Emitting-Isotopes Activated by Modulated Spot-Scanning Particle Beams

Purpose: To present the characteristics of positron-emitting-isotope (PEI) activity distributions on homogeneous and CIRS thorax phantoms irradiated by modulated spot-scanning carbon-ions and protons in Siemens IONTRIS system. Methods and Materials: Cylindrical homogeneous wax was irradiated by carbon-ions and protons of 10cm uniform square field with single-energy-layer ranges of 7cm, 16cm and 29cm. Images of PEI distributions were acquired over a period of 30 minutes at 10 minutes after each irradiation. Optimized uniform biological-equivalent doses of carbon-ions over a 5.0cm spherical target was delivered to CIRS phantom. Doses with range shifts in depths from 1mm to 6mm were also calculated and delivered to evaluate the accuracy of measuring activated PEI distributions. Results: Activated PEI distribution on homogeneous phantoms showed sharper peak near distal edge with flatter distribution toward proximal depth by carbon-ions than by protons. For depths near at Bragg-peak, penetration-depth spreading for energies from 10MeV/u to 60 MeV/u are from 0.4mm to 10.3mm, and 1.2mm to 30.4mm for projectile-fragments by carbon-ions and target-fragments by protons, respectively. For depths proximal to Bragg-peak, target-fragments for both carbon-ions and protons had minimal energy dependence in depth. For complex dose distributions delivered to CIRS thorax phantom, similar PEI peak-like distributions were still observed for carbon-ions. And, the changes at locations and edges of measured PEI peak were correlated within 0.5mm of shifted ranges. Mean activities over 5.0cm spherical target were similar for CISR phantom irradiated by doses with various range shifts. Conclusions: Peak-like PEI distributions by carbon-ions with good correlation to distal edges in both homogeneous and CIRS thorax phantoms present the potential for the in-vivo range verification while additional efforts is needed for protons. Due to flat distributions for depths at 6mm proximal to distal edges, mean activity at target might be used for in-vivo dose verification of target.

60 APPLIED LIFE SCIENCES↗

Measurement of the direct CP asymmetry in B¯->Xs+dy decays with a lepton tag

We report the measurement of the direct CP asymmetry in the radiative B¯?Xs+d? decay using a data sample of (772±11)×106 BB¯ pairs collected at the ?(4S) resonance with the Belle detector at the KEKB asymmetric-energy e+e- collider. The CP asymmetry is measured as a function of the photon energy threshold. For E*?=2.1 GeV, where E*? is the photon energy in the center-of-mass frame, we obtain ACP(B¯?Xs+d?)=(2.2±3.9±0.9)%, consistent with the Standard Model prediction.

Pesantez, L↗

Observation of X ( 3872 ) in B → X ( 3872 ) K π decays

We report the first observation of B 0 →X(3872)(K + π – ) and evidence for B + → X(3872)(K 0 π + ). We measure the product of branching fractions for the former to be B(B 0 → X(3872)(K + π – )) × B(X(3872) → J/ψπ + π – ) = (7.9 ± 1.3(stat) ± 0.4(syst)) × 10 –6 and find that B 0 → X(3872)K*(892) 0 does not dominate the B 0 → X(3872)K + π – decay mode. We also measure B(B + → X(3872)(K 0 π + )) × B(X(3872) → J/ψπ + π – ) = (10.6 ± 3.0(stat) ± 0.9(syst)) × 10 –6 . Furthermore, this study is based on the full data sample of 711 fb –1 (772 × 10 6 BB¯ pairs) collected at the Υ(4S) resonance with the Belle detector at the KEKB collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗