Progress and directions in low-cost redox flow batteries for large-scale energy storage
This article reviews recent progresses and directions of redox flow battery technologies.
Engineering topics
Publications and source records attributed to Li, Bin.
This article reviews recent progresses and directions of redox flow battery technologies.
The microstructure of the perfluorinated sulfonic acid proton exchange membranes such as Nafion significantly affects their transport properties and performance in a vanadium redox flow battery (VRB). In this work, Nafion membranes with various equivalent weights (EW) ranging from 1000 to 1500 are prepared and the structure-property-performance relationship is investigated. Nuclear magnetic resonance (NMR) and small-angle X-ray scattering (SAXS) studies revealed their composition and morphology variances, which lead to major differences in key transport properties related to proton conduction and vanadium ion permeation. Their performances are further characterized as VRB membranes. Based on those understanding, a new perfluorosulfonic acid membrane is designed with optimal pore geometry and thickness, leading to higher ion selectivity and lower cost compared with the widely used Nafion® 115. Excellent VRB single-cell performance (89.3% energy efficiency at 50mA∙cm-2) was achieved along with a stable cyclical capacity over prolonged cycling.
Abstract not provided
Nonaqueous redox flow batteries are promising in pursuit of high-energy storage systems owing to the broad voltage window, but currently are facing key challenges such as poor cycling stability and lack of suitable membranes. Here we report a new nonaqueous all-organic flow chemistry that demonstrates an outstanding cell cycling stability primarily because of high chemical persistency of the organic radical redox species and their good compatibility with the supporting electrolyte. A feasibility study shows that Daramic® and Celgard® porous separators can lead to high cell conductivity in flow cells thus producing remarkable cell efficiency and material utilization even at high current operations. This result suggests that the thickness and pore size are the key performance-determining factors for porous separators. With the greatly improved flow cell performance, this new flow system largely addresses the above mentioned challenges and the findings may greatly expedite the development of durable nonaqueous flow batteries.
A large-area (6 cm × 6 cm) air surface dielectric barrier discharge has been generated at atmospheric pressure by using well-aligned and micron-sized dielectric tubes with tungsten wire electrodes. Intensified CCD images with an exposure time of 5 ns show that the uniform surface air discharge can be generated during the rising and falling time of pulsed DC voltage. Current and voltage and optical measurements confirm the formation of glow-like air discharges on the surface of micron-sized dielectric tubes. Simulation results indicate that the microelectrode configuration contributes to the formation of strong surface electric field and plays an important role in the generation of uniform surface air discharge.
This paper presents MOFs serving as catalysts are applicable in zinc-ployioidide redox flow batteries.
The wide-band-gap (WBG) devices based 6.6 kW bidirectional on-board charger (OBC) system for plug-in electric vehicles (PEVs) is recently developed. With the proposed novel variable DC-link voltage system architecture, high frequency soft switching operation, and integrated magnetics, the OBC system becomes more compact and more efficient compared to a Sibased counterpart. The design considerations of the AC/DC stage are introduced in this paper including the evaluation of 1.2 kV SiC MOSFETs; the zero-voltage-switching (ZVS) extension function for the line-cycle ZVS operation; and the novel universal control strategy for both the rectifier mode and the inverter mode. The prototype of the AC/DC stage is built which achieves 98.5% efficiency at higher than 300 kHz switching frequency. Finally, the complete 6.6 kW OBC system using both SiC and GaN devices is demonstrated with 37 W/in3 power density and above 96% efficiency.
We report Shanghai Tian Ma Radio Telescope (TMRT) detections of several long carbon-chain molecules in the C and Ku bands, including HC{sub 3}N, HC{sub 5}N, HC{sub 7}N, HC{sub 9}N, C{sub 3}S, C{sub 6}H, and C{sub 8}H toward the starless cloud Serpens South 1a. We detected some transitions (HC{sub 9}N J = 13–12, F = 12–11, and F = 14–13; H{sup 13}CCCN J = 2–1, F = 1–0, and F = 1–1; HC{sup 13}CCN J = 2–1, F = 2–2, F = 1–0, and F = 1–1; HCC{sup 13}CN J = 2–1, F = 1–0, and F = 1–1) and resolved some hyperfine components (HC{sub 5}N J = 6–5, F = 5–4; H{sup 13}CCCN J = 2–1, F = 2–1) for the first time in the interstellar medium. The column densities of these carbon-chain molecules in the range 10{sup 12}–10{sup 13} cm{sup −2} are comparable to two carbon-chain molecule rich sources, TMC-1 and Lupus-1A. The abundance ratios are 1.00:(1.11 ± 0.15):(1.47 ± 0.18) for [H{sup 13}CCCN]:[HC{sup 13}CCN]:[HCC{sup 13}CN]. This result implies that the {sup 13}C isotope is also concentrated in the carbon atom adjacent to the nitrogen atom in HC{sub 3}N in Serpens South 1a, which is similar to TMC-1. The [HC{sub 3}N]/[H{sup 13}CCCN] ratio of 78 ± 9, the [HC{sub 3}N]/[HC{sup 13}CCN] ratio of 70 ± 8, and the [HC{sub 3}N]/[HCC{sup 13}CN] ratio of 53 ± 4 are also comparable to those in TMC-1. Serpens South 1a proves to be a suitable testing ground for understanding carbon-chain chemistry.
Abstract A dual oxidative approach using O 2 plasma followed by treatment with H 2 O 2 to impart oxygen functional groups onto the surface of a graphite felt electrode. When used as electrodes for an all‐vanadium redox flow battery (VRB) system, the energy efficiency of the cell is enhanced by 8.2 % at a current density of 150 mA cm −2 compared with one oxidized by thermal treatment in air. More importantly, by varying the oxidative techniques, the amount and type of oxygen groups was tailored and their effects were elucidated. It was found that O−C=O groups improve the cells performance whereas the C−O and C=O groups degrade it. The reason for the increased performance was found to be a reduction in the cell overpotential after functionalization of the graphite felt electrode. This work reveals a route for functionalizing carbon electrodes to improve the performance of VRB cells. This approach can lower the cost of VRB cells and pave the way for more commercially viable stationary energy storage systems that can be used for intermittent renewable energy storage.
We demonstrate the application of the Chevrel phase Mo6S8 nanocubes as the anode material for rechargeable Zn-ion batteries. Mo6S8 can host Zn2+ ions reversibility both in aqueous and nonaqueous electrolytes with specific capacities around 90 mAh/g and exhibited remarkable intercalation kinetics as well as stability. Furthermore, we assembled full cells by integrating Mo6S8 anode with zinc-polyiodide (I-/I3-) based catholytes, and demonstrated that such fuel cells was also able to deliver outstanding rate performance and cyclic stability. This first demonstration of zinc intercalating anode could inspire the design of advanced Zn ion batteries.
We report on the in situ engineering of hybrid Co-picene magnetic structures with variable spin coupling using a low-temperature scanning tunneling microscope. Single picene molecules adsorbed on Au(111) are manipulated to accommodate individual Co atoms one by one, forming stable artificial hybrid structures with magnetism introduced by the Co atoms. By monitoring the evolution of the Kondo effect at each site of Co atom, we found that the picene molecule plays an important role in tuning the spin coupling between individual Co atoms, which is confirmed by theoretical calculations based on the density-functional theory. Our findings indicate that the hybrid metal-molecule structures with variable spin coupling on surfaces can be artificially constructed in a controlled manner.
Purpose: In computed tomography perfusion (CTP) imaging, an initial phase CT acquired with a high-dose protocol can be used to improve the image quality of later phase CT acquired with a low-dose protocol. For dynamic regions, signals in the later low-dose CT may not be completely recovered if the initial CT heavily regularizes the iterative reconstruction process. The authors propose a hybrid nonlocal means (hNLM) regularization model for iterative reconstruction of low-dose CTP to overcome the limitation of the conventional prior-image induced penalty. Methods: The hybrid penalty was constructed by combining the NLM of the initial phase high-dose CT in the stationary region and later phase low-dose CT in the dynamic region. The stationary and dynamic regions were determined by the similarity between the initial high-dose scan and later low-dose scan. The similarity was defined as a Gaussian kernel-based distance between the patch-window of the same pixel in the two scans, and its measurement was then used to weigh the influence of the initial high-dose CT. For regions with high similarity (e.g., stationary region), initial high-dose CT played a dominant role for regularizing the solution. For regions with low similarity (e.g., dynamic region), the regularization relied on a low-dose scan itself. This new hNLM penalty was incorporated into the penalized weighted least-squares (PWLS) for CTP reconstruction. Digital and physical phantom studies were performed to evaluate the PWLS-hNLM algorithm. Results: Both phantom studies showed that the PWLS-hNLM algorithm is superior to the conventional prior-image induced penalty term without considering the signal changes within the dynamic region. In the dynamic region of the Catphan phantom, the reconstruction error measured by root mean square error was reduced by 42.9% in PWLS-hNLM reconstructed image. Conclusions: The PWLS-hNLM algorithm can effectively use the initial high-dose CT to reconstruct low-dose CTP in the stationary region while reducing its influence in the dynamic region.
Mass spectrometry imaging (MSI) has become an important analytical tool for many sectors of science and medicine. As the application of MSI expands into new areas of inquiry, existing methodologies must be adapted and improved to meet emerging challenges. In particular salient is the need for small molecule imaging methods that are compatible with complex multicomponent systems, a challenge that is amplified by the effects of analyte migration and matrix interference. Furthermore, with a focus on microbial biofilms from the opportunistic pathogen Pseudomonas aeruginosa, the relative advantages of two established microprobe-based MSI techniques—polyatomic secondary ion mass spectrometry (SIMS) and laser desorption/ionization—are compared, with emphasis on exploring the effect of surface metallization on small molecule imaging. A combination of qualitative image comparison and multivariate statistical analysis demonstrates that sputtering microbial biofilms with a 2.5 nm layer of gold selectively enhances C 60 -SIMS ionization for several molecular classes including rhamnolipids and 2-alkyl-quinolones. Metallization also leads to the reduction of in-source fragmentation and subsequent ionization of media-specific background polymers, which improves spectral purity and image quality. Our findings show that the influence of metallization upon ionization is strongly dependent on both the surface architecture and the analyte class, and further demonstrate that metal-assisted C 60 -SIMS is a viable method for small molecule imaging of intact molecular ions in complex biological systems. VC 2016 American Vacuum Society.