Boosting Activity and Selectivity of CO2 Electroreduction by Pre-Hydridizing Pd Nanocubes
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Lee, J..
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A novel scheme to measure the longitudinal emittance and phase space profile in an electron storage ring by using correlations between time and the vertical coordinate, and between energy and the horizontal coordinate, is proposed. This longitudinal profile measurement scheme will help to demonstrate recent results of advanced studies for manipulating the longitudinal beam profile and for investigating beam instability in an electron storage ring.
Explore the source record for details and available documents.
Superconducting properties of Nb in microwave fields vary significantly with lattice defects and impurity content, where sub-at.% impurity level can reduce or increase microwave surface resistance by an order of magnitude. In this study, we studied the microwave properties of Nb films, deposited by different PVD techniques, at low microwave fields correlating microwave properties at dilution fridge temperatures with material properties characterized with surface science techniques. We are studying the microwave properties of Nb films, deposited by different PVD techniques, at low microwave fields and low temperatures. The first Nb film, deposited onto an elliptical niobium cavity by HiPIMS technique at CERN, was tested at low temperatures. The first results show that film performance was similar to that of the bulk niobium cavities.
Explore the source record for details and available documents.
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of 134 Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity to search for the double beta decay of 134 Xe, for which xenon detectors enriched in 136 Xe are less effective. For the two-neutrino decay mode, LZ is predicted to exclude values of the half-life up to 1.7 x 10 24 years at 90% confidence level (CL), and has a three-sigma observation potential of 8.7 x 10 23 years, approaching the predictions of nuclear models. For the neutrinoless decay mode LZ, is projected to exclude values of the half-life up to 7.3 x 10 24 years at 90% CL.
LUX-ZEPLIN is a dark matter detector expected to obtain world-leading sensitivity to weakly-interacting massive particles interacting via nuclear recoils with a ∼7-tonne xenon target mass. This paper presents sensitivity projections to several low-energy signals of the complementary electron recoil signal type: 1) an effective neutrino magnetic moment, and 2) an effective neutrino millicharge, both for 𝑝𝑝-chain solar neutrinos, 3) an axion flux generated by the Sun, 4) axionlike particles forming the Galactic dark matter, 5) hidden photons, 6) mirror dark matter, and 7) leptophilic dark matter. World-leading sensitivities are expected in each case, a result of the large 5.6 t 1000 d exposure and low expected rate of electron-recoil backgrounds in the <100 keV energy regime. A consistent signal generation, background model and profile-likelihood analysis framework is used throughout.
Explore the source record for details and available documents.
A first γ -ray study of Cl 47 , 49 spectroscopy was performed at the Radioactive Isotope Beam Factory with Ar 50 projectiles at 217 MeV/nucleon, impinging on the liquid hydrogen target of the MINOS device. Prompt deexcitation γ rays were measured with the NaI(Tl) array DALI2 + . Through the one-proton knockout reaction Ar 50 ( p , 2 p ) , a spin assignment could be determined for the low-lying states of Cl 49 from the momentum distribution obtained with the SAMURAI spectrometer. A spin-parity J π = 3 / 2 + is deduced for the ground state of Cl 49 , similar to the recently studied N = 32 isotope K 51 . The evolution of the energy difference E ( 1 / 2 1 + ) - E ( 3 / 2 1 + ) is compared to state-of-the-art theoretical predictions.
A discrepancy in the asymmetry dependence of spectroscopic factors extracted with different reaction probes calls into question whether the corresponding reaction models are properly understood. In this work, we present extracted spectroscopic factors from the Ar 46 , 34 ( p , d ) Ar 45 , 33 transfer reactions in inverse kinematics at a beam energy of 70 MeV/nucleon. The results are consistent with previous measurements of these reactions at a lower beam energy [Lee et al. , Phys. Rev. Lett. 104 , 112701 (2010) ], indicating that the transfer reaction is a reliable probe for the nuclear structure of exotic nuclei across a wide energy range. Results from a large body of transfer reaction measurements, ( p , p N ) measurements, and theoretical nuclear structure studies make a compelling case for much weaker asymmetry dependence than what is observed with single-nucleon knockout reactions on beryllium or carbon targets.
Results from KSTAR powder injection experiments, in which tens of milligrams of boron nitride (BN) were dropped into low-power H-mode plasmas, show an improvement in wall conditions in subsequent discharges and, in some cases, a reduction or elimination of edge-localized modes (ELMs). Injected powder is distributed by the plasma flow and is deposited on the wall and, over the course of several discharges, was observed to gradually reduce recycling by 33%, and decrease both the ELM amplitude and frequency. This is the first demonstration of the use of BN for ELM mitigation. In all of these experiments, an Impurity Powder Dropper (IPD) was used to introduce precise, controllable amounts of the materials into ELMy H-mode KSTAR discharges. The plasma duration was between 10 s and 15 s, I p = 500 kA, B T = 1 . 8 T, P NBI = 1 . 6 MW, and P ECH = 0 . 6 MW. Plasma densities were between 2 and 3 × 1 0 19 m -3 . In all cases, the pre-fill and startup gas-fueling was kept constant, suggesting that the decrease in baseline D α emission is in fact due to a reduction in recycling. The results presented herein highlight the viability of powder injection for intra-shot and between-shot wall conditioning
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3×3×57 mm3 and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to a most probable value (MPV) of energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.