Engineering PapersSearch

Engineering topics

Hynecek, J.

Publications and source records attributed to Hynecek, J..

Texas Instruments' virtual phase charge-coupled device (CCD) imager operated in the frontside electron-bombarded mode

The present investigation is concerned with the suitability of the virtual phase CCD imager for frontside detection of electrons up to 25 keV. The investigation has the objective to determine if the imager can be used in the frontside mode with a photocathode to detect very low light levels in astronomical applications, the ultimate goal being individual photon detection. It is found that the standard virtual phase imager will function properly over an extended period at low levels of 20 kV electron irradiation consistent with photon counting applications. The imager can detect individual primary electrons with nearly 100 percent efficiency. However, further studies are needed to determine the mechanisms for the flat band shifts so that the imager design may be modified to eliminate or at least reduce them.

Everett, P.

Virtual phase imager for Galileo

A CCD imaging array with a new virtual-phase technology that has been developed for use in a slow-scan imaging system for NASA's Galileo mission to Jupiter is described. Among its features are an absence of interlevel shorts, simplicity of fabrication, low dark current (less than 0.4 nA/sq cm), high full well, high quantum efficiency in the front side illumination mode, large dynamic range (greater than 5000), good charge transfer efficiency (0.99997), excellent linearity (0.2%), uniform pixel response (1%), and improved radiation hardness. It is noted that its operating voltages must be constrained to narrow windows to maintain good charge transfer efficiency and avoid the production of spurious and leakage charge.

Janesick, J. R.

Single frequency RF powered ECG telemetry system

It has been demonstrated that a radio frequency magnetic field can be used to power implanted electronic circuitry for short range telemetry to replace batteries. A substantial reduction in implanted volume can be achieved by using only one RF tank circuit for receiving the RF power and transmitting the telemetered information. A single channel telemetry system of this type, using time sharing techniques, was developed and employed to transmit the ECG signal from Rhesus monkeys in primate chairs. The signal from the implant is received during the period when the RF powering radiation is interrupted. The ECG signal is carried by 20-microsec pulse position modulated pulses, referred to the trailing edge of the RF powering pulse. Satisfactory results have been obtained with this single frequency system. The concept and the design presented may be useful for short-range long-term implant telemetry systems.

Ko, W. H.

Microelectronic bioinstrumentation systems

The possibility of using RF fields to power biologically implanted transmitters used in biomedical experiments was investigated. This approach would be especially useful when animal subjects are strapped in chairs or confined in cages. A telemetry system using an external source of energy has the additional advantage of not being limited in operation by battery lifetime and can therefore operate for virtually infinite lengths of time. A description of a system based on this principle is given. Progress in the development of battery-driven transmitters is also reported, including an ingestible temperature telemetry system and a resistance-to-pulse frequency convertor for implantable temperature telemetry systems.

Ko, W. H.