Engineering Papers⌕ Search

Engineering topics

Huang, X.

Publications and source records attributed to Huang, X..

At least 55 records · Page 3

Measurement of Sequential ϒ Suppression in Au + Au Collisions at $\sqrt{s_{NN}}$ = 200 GeV with the STAR Experiment

We report on measurements of sequential ϒ suppression in Au+Au collisions at $\sqrt{s_{NN}}$ = 200 GeV with the STAR detector at the Relativistic Heavy Ion Collider (RHIC) through both the dielectron and dimuon decay channels. In the 0%–60% centrality class, the nuclear modification factors (𝑅 𝐴⁢𝐴 ), which quantify the level of yield suppression in heavy-ion collisions compared to 𝑝 + 𝑝 collisions, for ϒ⁡(1⁢𝑆) and ϒ⁡(2⁢𝑆) are 0.40 ± 0.03⁢(stat) ± 0.03⁢(sys) ± 0.09⁢(norm) and 0.26 ± 0.08⁢(stat) ± 0.02⁢(sys) ± 0.06⁢(norm), respectively, while the upper limit of the ϒ⁡(3⁢𝑆) 𝑅 𝐴⁢𝐴 is 0.17 at a 95% confidence level. This provides experimental evidence that the ϒ⁡(3⁢𝑆) is significantly more suppressed than the ϒ⁡(1⁢𝑆) at RHIC. The level of suppression for ϒ⁡(1⁢𝑆) is comparable to that observed at the much higher collision energy at the Large Hadron Collider. Furthermore, these results point to the creation of a medium at RHIC whose temperature is sufficiently high to strongly suppress excited ϒ states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for the chiral magnetic effect in Au+Au collisions at $\sqrt{s_{NN}}$ = 27 GeV with the STAR forward event plane detectors

A decisive experimental test of the Chiral Magnetic Effect (CME) is considered one of the major scientific goals at the Relativistic Heavy-Ion Collider (RHIC) towards understanding the nontrivial topological fluctuations of the Quantum Chromodynamics vacuum. In heavy-ion collisions, the CME is expected to result in a charge separation phenomenon across the reaction plane, whose strength could be strongly energy dependent. The previous CME searches have been focused on top RHIC energy collisions. In this Letter, we present a low energy search for the CME in Au+Au collisions at $\sqrt{s_{NN}}$ = 27 GeV. We measure elliptic flow scaled charge-dependent correlators relative to the event planes that are defined at both mid-rapidity |η| < 1.0 and at forward rapidity 2.1 < |η| < 5.1. We compare the results based on the directed flow plane ( $Ψ$ 1 ) at forward rapidity and the elliptic flow plane ( $Ψ$ 2 ) at both central and forward rapidity. The CME scenario is expected to result in a larger correlation relative to $Ψ$ 1 than to $Ψ$ 2 , while a flow driven background scenario would lead to a consistent result for both event planes. In 10-50% centrality, results using three different event planes are found to be consistent within experimental uncertainties, suggesting a flow driven background scenario dominating the measurement. We obtain an upper limit on the deviation from a flow driven background scenario at the 95% confidence level. This work opens up a possible road map towards future CME search with the high statistics data from the RHIC Beam Energy Scan Phase-II.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Energy Dependence of Fifth- and Sixth-Order Net-Proton Number Fluctuations in Au + Au Collisions at RHIC

We report the beam energy and collision centrality dependence of fifth and sixth order cumulants (C 5 , C 6 ) and factorial cumulants (κ 5 , κ 6 ) of net-proton and proton distributions, from $\sqrt{s_{NN}}$=3-200 GeV Au+Au collisions at RHIC. The net-proton cumulant ratios generally follow the hierarchy expected from QCD thermodynamics, except for the case of collisions at $\sqrt{s_{NN}}$ = 3 GeV. C 6 /C 2 for 0-40\% centrality collisions is increasingly negative with decreasing $\sqrt{s_{NN}}$, while it is positive for the lowest $\sqrt{s_{NN}}$ studied. These observed negative signs are consistent with QCD calculations (at baryon chemical potential, μ B ≤ 110 MeV) that include a crossover quark-hadron transition. In addition, for $\sqrt{s_{NN}}$≥ 11.5 GeV, the measured proton κ n , within uncertainties, does not support the two-component shape of proton distributions that would be expected from a first-order phase transition. Taken in combination, the hyper-order proton number fluctuations suggest that the structure of QCD matter at high baryon density, μ B ~750 MeV ($\sqrt{s_{NN}}$ = 3 GeV) is starkly different from those at vanishing μ B ~20MeV ($\sqrt{s_{NN}}$ = 200 GeV and higher).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GBT20, a 20.48 Gbps PAM4 Optical Transmitter Module for Particle Physics Experiments

We present a pluggable radiation-tolerant 4-level Pulse-Amplitude-Modulation (PAM4) optical transmitter module called GBT20 (Giga-Bit Transmitter at 20 Gbps) for particle-physics experiments. GBT20 has an OSFP or firefly connector to input 16-bit data each at 1.28 Gbps. The GBT20 drives a VCSEL die with an LC lens or a VCSEL TOSA and interfaces an optical fiber with a standard LC connector. The minimum module, including the host connector, occupies 41 mm x 13 mm x 6 mm. At 20.48 Gbps, the minimum Transmitter Dispersion Eye Closure Quaternary (TDECQ) is around 0.7 dB. The power consumption is around 164 mW in the low-power mode. The SEE cross-section is below 7.5x10^(-14) cm^2. No significant performance degrades after a TID of 5.4 kGy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An FPGA-based readout chip emulator for the CMS ETL detector upgrade

Here, we present an FPGA-based readout chip emulator board for the CMS Endcap Timing Layer (ETL) detector upgrade. The emulator board uses an Intel Cyclone 10 GX FPGA to emulate the digital functions of four Endcap Layer Readout Chips (ETROCs). Based on the actual ETROC design, the firmware is implemented and verified. The emulator board is being used for the ETROC digital design verification and system development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pion, kaon, and (anti)proton production in $\cup + \cup$ collisions at $\sqrt{s_{NN}} = 193$ GeV measured with the STAR detector

We present the first measurements of transverse momentum spectra of $π^±, K^±, p(\overline{p})$ at midrapidity ($|y|$ < 0.1) in $\cup + \cup$ collisions at $\sqrt{s_{NN}} = 193$ GeV with the STAR detector at the Relativistic Heavy Ion Collider (RHIC). The centrality dependence of particle yields, average transverse momenta, particle ratios and kinetic freezeout parameters are discussed. The results are compared with the published results from Au+Au collisions at $\sqrt{s_{NN}} = 200$ GeV in STAR. The results are also compared to those from A Multi Phase Transport (AMPT) model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The design and test results of A Giga-Bit Cable Receiver (GBCR) for the ATLAS Inner Tracker Pixel Detector

This paper presents the design and test results of a Gigabit Cable Receiver ASIC called GBCR for the HL-LHC upgrade of the ATLAS Inner Tracker (ITk) pixel detector. Three prototypes (GBCR1, GBCR2, and GBCR3) have been designed in the CERN-identified 65 nm CMOS technology. GBCR receives seven (GBCR2) or six (GBCR3) channels (RX) each at 1.28 Gbps from the front-end readout chip RD53B via flex cables up to 1 meter and Twinax cables up to 5 meters and sends the equalized and retimed signals to lpGBT. Both GBCR2 and GBCR3 ASICs have two transmitting channels (TX) that pre-emphasize the signals from lpGBT before sending them to RD53B through the same cables. No Single-Event Upset (SEU) is observed in any tested channels of GBCR2 in a 400 MeV proton beam. The extrapolated bit error rate for the future HL-LHC application is below 8*10^(-16), significantly below the specified BER criterion. GBCR3 is designed to improve the immunity to single-event-upset by applying the Triple Modular Redundancy (TMR) technology to all RX channels. The retimed signals from GBCR3 have less total jitter than those from GBCR2 (35 ps versus 79 ps). Each receiver channel of GBCR3 consumes 75% more power than that of GBCR2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TDC with uncontrolled delay lines: calibration approaches and precision improvement methods

The time-to-digital-converter (TDC) using uncontrolled delay lines has a simple structure and finer measurement precision since the delay cells are pure digital gates that operate at maximum speed. For every incoming hit, two “snapshots” of the delay line are taken by the register array with two strobes separated with a known time interval. With two measurements, propagation delays of each cell in the delay line can be calibrated for the operating temperature and voltage. The two measurements can also be averaged to improve the TDC measurement precision. We will discuss various calibration approaches and present test results in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A high-resolution clock phase shifter circuitry for ALTIROC

Abstract A high-resolution clock phase shifter is implemented to adjust the phase of multiple clocks at 40 MHz, 80 MHz, or 640 MHz in the ALTIROC chip. The phase shifter has a coarse-phase shifter and a fine-phase shifter to achieve a step size of 97.7 ps and an adjustable range of 25 ns. The fine delay unit is based on a Delay Locked Loop (DLL) operating at 640 MHz. The phase shifter is fabricated in a 130 nm CMOS process. The area of the phase shifter is 725 µm × 248 µm. The Differential Non-Linearity (DNL) and the Integral Non-Linearity (INL) are ±0.6 LSB and ±0.75 LSB, respectively. The jitter from −25 °C to 20 °C is less than 15.5 ps (RMS), including the contributions from the FPGA clock source and the PLL. The power consumption is 11.2 mW.

Instruments & Instrumentation↗

Toward fully coherent soft x-ray free-electron laser via echo-enabled harmonic generation in fourth generation synchrotron light sources

Having previously reported on bunching via echo-enabled harmonic generation (EEHG) as an effective way to improve the longitudinal coherence in the NSLS-II storage ring [X. Yang et al., Sci. Rep. 12, 9437 (2022)], we demonstrate that this EEHG scheme can be easily adopted to any fourth generation diffraction-limited synchrotron light source with significant benefits. The advantage of the scheme is that it requires no change of the lattice and is fully compatible with other beamlines. Since the EEHG performance is mainly determined by the momentum compaction, beam emittances, and beta functions of a SR lattice, we have identified these crucial parameters and successfully built a generalized model, which can predict the performance of nearly any SLS. Regarding the fourth generation SLSs, momentum compactions are often significantly smaller; thus, to cover the x rays with a photon energy of up to 1 keV, we utilize a specific design, including a 250 nm seed-laser wavelength. Our model predicts that for most of the current and future fourth generation SLSs, the EEHG scheme can produce significant prebunching up to harmonic 200 and, thus, generate a few MW scale peak power at 1.25 nm wavelength.

47 OTHER INSTRUMENTATION↗

A new Kirkpatrick–Baez-based scanning microscope for the Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II

The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.

36 MATERIALS SCIENCE↗

QTIA, a 2.5 or 10 Gbps 4-channel array optical receiver ASIC in a 65 nm CMOS technology

Here, the Quad transimpedance and limiting amplifier (QTIA) is a 4-channel array optical receiver ASIC, developed using a 65 nm CMOS process. It is configurable between the bit rate of 2.56 Gbps and 10 Gbps per channel. QTIA offers careful matching to both GaAs and InGaAs photodiodes. At this R&D stage, each channel has a different biasing scheme to the photodiode for optimal coupling. A charge pump is implemented in one channel to provide a higher reverse bias voltage, which is especially important to mitigate radiation effects on the photodiodes. The circuit functions of QTIA successfully passed the lab tests with GaAs photodiodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A radiation tolerant clock generator for the CMS endcap timing layer readout chip

Here, we present the test results of a low jitter Phase Locked Loop (PLL) prototype chip for the CMS Endcap Timing Layer readout chip (ETROC). This chip is based on the improved version of a clock synthesis circuit named ljCDR from the Low Power Gigabit Transceiver (lpGBT) project. The ljCDR is tested in its PLL mode. An automatic frequency calibration (AFC) block with the Triple Modular Redundancy (TMR) register is developed for the LC-oscillator calibration. The chip was manufactured in a 65 nm CMOS process with 10 metal layers. The chip has been extensively tested, including Total Ionizing Dose (TID) testing up to 300 Mrad and Single Event Upset (SEU) testing with heavy ions possessing a Linear Energy Transfer (LET) from 1.3 to 62.5 MeV × cm 2 /mg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗