Engineering Papers⌕ Search

Engineering topics

Hilado, C. J.

Publications and source records attributed to Hilado, C. J..

At least 55 records · Page 3

Relative toxicity of materials in fire situations

The results of toxicity testing of additional materials is presented. Relative toxicity data on polymers by generic type are presented and include wood, polyurethane flexible foam, polyvinyl chloride (PVC), acrylonitrile/butadiene/styrene (ABS), and polyisoprene (natural rubber). A second table gives relative toxicity data on fibers and fabrics including wool, nylon, rayon, polyester, and aromatic polyamide. Sulfur-containing materials seemed to exhibit the shortest times to death of laboratory animals. Some chlorine-containing polymers tended to exhibit shortest time to death also while some halogen-containing polymers gave the shortest time to incapacitation. Among fibers and fabrics, wool, silk, and polyester exhibited the shortest times to incapacitation and times to death. Difficulty in restricting generally accepted materials is discussed and attention is given to other factors important in comparing materials, such as backcoatings and relative weights.

Hilado, C. J.↗

ALC/50/ values for some polymeric materials

Apparent lethal concentrations for 50 per cent of the test animals within a 30-min exposure period (ALC/50/) were determined for seventeen samples of polymeric materials, using the screening test method. The materials evaluated included resin-glass composites, film composites, and miscellaneous resins. ALC(50) values, based on weight of original sample charged, ranged from 24 to 110 mg/l. Modified phenolic resins seemed to exhibit less toxicity than the baseline epoxy resins. Among the film composites evaluated, only flame modified polyvinyl fluoride appeared to exhibit less toxicity than the baseline polyvinyl fluoride film.

Hilado, C. J.↗

Reproducibility of toxicity test data as a function of mouse strain, animal lot, and operator

The toxicity screening test method developed at the University of San Francisco was evaluated for reproducibility. The variables addressed were strain of mouse, lot of animals, and operator. There was a significant difference in response between Swiss Webster mice and ICR mice, with the latter exhibiting greater resistance. These two strains of mice are not interchangeable in this procedure. Variation between individual animals was significant and unavoidable. In view of this variation, between-lot and between-operator variations appear to have no practical significance. The significant variation between individual animals stresses the need for average values based on at least four animals, and preferably values based on at least two experiments and eight animals. Efforts to compare materials should be based on the evaluation of relatively simple responses using substantial numbers of animals, rather than on elaborate evaluation of single animals

Hilado, C. J.↗

Concentration-response data on toxicity of pyrolysis gases from six synthetic polymers

Concentration-response data are presented on the toxic effects of the pyrolysis gases from six synthetic polymers on Swiss Webster male mice, using a toxicity screening test method. The polymers consisted of one sample each of polycarbonate and polystyrene, and two samples each of polyethylene and acrylonitrile-butadiene-styrene (ABS). All six samples were evaluated using the rising temperature program, and three samples were evaluated using the fixed temperature program. The pyrolysis gases from polycarbonate, polyethylene, and ABS appeared to exhibit the concentration-response relationships commonly encountered in toxicology. The polystyrene sample gave variable results; probably due to poor reproducibility of the essentially anaerobic pyrolysis. Carbon monoxide seemed to be the principal toxicant in the pyrolysis gases from polycarbonate and polyethylene, but did not appear to be the principal toxicant in the pyrolysis gases from ABS.

Hilado, C. J.↗

Relative toxicity of pyrolysis gases from materials - Effects of chemical composition and test conditions

Relative toxicity test data on 270 materials are presented, based on test procedures developed at the University of San Francisco. The effects of chemical composition, using data on 13 types of synthetic polymers and eight types of fabrics, are discussed. Selected materials were evaluated using nine test conditions with the USF method, and using methods developed at the FAA Civil Aeromedical Institute, Douglas Aircraft Company and San Jose State University.

Hilado, C. J.↗

Toxicity of pyrolysis gases from wood

The toxicity of the pyrolysis gases from nine wood samples was investigated. The samples of hardwoods were aspen poplar, beech, yellow birch, and red oak. The samples of softwoods were western red cedar, Douglas fir, western hemlock, eastern white pine, and southern yellow pine. There was no significant difference between the wood samples under rising temperature conditions, which are intended to simulate a developing fire, or under fixed temperature conditions, which are intended to simulate a fully developed fire. This test method is used to determine whether a material is significantly more toxic than wood under the preflashover conditions of a developing fire.

Hilado, C. J.↗

Toxicity of pyrolysis gases from synthetic polymers

The screening test method was used to investigate toxicity in polyethylene, polystyrene, polymethyl methacrylate, polyaryl sulfone, polyether sulfone, polyphenyl sulfone, and polyphenylene sulfide. Changing from a rising temperature program to a fixed temperature program resulted on shorter times to animal responses. This effect was attributed in part to more rapid generation of toxicants. The toxicants from the sulfur containing polymers appeared to act more rapidly than the toxicants from the other polymers. It was not known whether this effect was due primarily to difference in concentration or in the nature of the toxicants. The carbon monoxide concentration found did not account for the results observed with the sulfur containing polymers. Polyphenyl sulfone appeared to exhibit the least toxicity among the sulfur containing polymers evaluated under these test conditions.

Hilado, C. J.↗

Standard wool fabric as a reference material

Standard wool fabric is investigated as a potential reference material. A screening test method for relative toxicity exposes four albino male rats enclosed in a 4.2 liter hemispherical chamber to pyrolysis effluents produced by pyrolyzing a 1.00 g sample under a variety of test conditions (200-800 C with a 40 C/min heating rate). It is found that for fabrics containing 86-100% wool, animal response remains virtually unchanged, although a 100% wool fabric is preferred as it eliminates local composition differences as a source of variation.

Hilado, C. J.↗

Polychloroprene flexible foam as a reference material

Polychloroprene flexible foam was evaluated as a reference material for fire toxicity tests. A commercial sample was evaluated using nine different test conditions of the USF methodology. The material exhibited a wide range of relative toxicity depending on the test conditions. Times to incapacitation and times to death were shortest at 16 ml/sec (1 l/min) air flow, at any fixed heating rate and upper limit temperature.

Hilado, C. J.↗

Effect of test conditions on relative toxicity rankings of fifteen materials

Fifteen materials were evaluated for relative toxicity of pyrolysis effluents, using different test conditions in the USF methodology. Wool fabrics were consistently among the most toxic materials, and polystyrene and polychloroprene flexible foam were consistently among the least toxic materials.

Hilado, C. J.↗

Effect of carbon monoxide and nitrogen dioxide on ICR mice

Times to incapacitation and death and LC(50) values were determined for male ICR mice exposed to different concentration of carbon monoxide for 30 min and of nitrogen dioxide for 10 min in a 4.2 liter hemispherical chamber. The data indicate that ICR mice are more resistant to these two toxicants than Swiss albino mice. The carbon monoxide LC(50) for a 30-min exposure was about 8,000 ppm for ICR mice compared to 3,570 ppm for Swiss albino mice. The nitrogen dioxide LC(50) for a 10-min exposure was above 2,000 ppm for ICR mice compared to about 1,000 ppm for Swiss albino mice.

Hilado, C. J.↗

Effect of heating rate on toxicity of pyrolysis gases from some synthetic polymers

The effect of heating rate on the toxicity of the pyrolysis gases from some synthetic polymers was investigate, using a screening test method. The synthetic polymers were polyethylene, polystyrene, polymethyl methacrylate, polycarbonate, ABS, polyaryl sulfone, polyether sulfone, and polyphenylene sulfide. The toxicants from the sulfur-containing polymers appeared to act more rapidly than the toxicants from the other polymers. It is not known whether this effect is due primarily to differences in concentration or in the nature of the toxicants. The carbon monoxide concentrations found do not account for the observed results.

Hilado, C. J.↗

Studies with the USF/NASA toxicity screening test method - Oxygen concentrations with various test conditions

Continuing efforts to increase the versatility of the USF/NASA toxicity screening test method have included the use of different test conditions in order to simulate various fire environments. The use of air flow at flow rates of 16 to 48 ml/sec maintains oxygen concentrations above 19 percent throughout the 30 min exposure period, compared to above 16 percent without forced air flow. These levels of oxygen are well within the tolerance range of mice, and approach the oxygen levels found in many real fire situations. Proposed minimum oxygen levels based on experience with rats are unduly restrictive on the use of other species such as mice, and tend to eliminate the cost savings which may more than justify the selection of mice.

Hilado, C. J.↗

Effect of heating rate on toxicity of pyrolysis gases from some elastomers

The effect of heating rate on the toxicity of the pyrolysis gases from six elastomers was investigated, using a screening test method. The elastomers were polyisoprene (natural rubber), styrene-butadiene rubber (SBR), ethylene propylene diene terpolymer (EPDM), acrylonitrile rubber, chlorosulfonated polyethylene rubber, and polychloroprene. The rising temperature and fixed temperature programs produced exactly the same rank order of materials based on time to death. Acrylonitrile rubber exhibited the greatest toxicity under these test conditions, and carbon monoxide was not found in sufficient concentrations to be the primary cause of death.

Hilado, C. J.↗

Flash fire propensity of materials

Flash fire test results on 86 materials, evaluated using the USF flash fire screening test, are presented. The materials which appear least prone to flash fires are PVC, polyphenylene oxide and sulfide, and polyether and polyaryl sulfone; these did not produce flash fires under these particular test conditions. The principal value of these screening tests at the present time is in identifying materials which appear prone to flash fires, and in identifying which formulations of a generic material are more or less prone to flash fires.

Hilado, C. J.↗

The prediction of toxic atmospheres from decomposing polymers

The generation of carbon monoxide from polymethyl methacrylate and polyethylene, and of hydrogen chloride from polyvinyl chloride, was calculated. Calculations were made for various amounts of polymer evolving gaseous products into a 60 cu ft compartment.

Buchler, A.↗

The use of a behavioral response system in the USF/NASA toxicity screening test method

Relative toxicity data on the pyrolysis effluents from bisphenol A polycarbonate and wool fabric were obtained, based on visual observations of the behavior of free-moving mice and on an avoidance response behavioral paradigm of restrained rats monitored by an instrumented behavioral system. The initial experiments show an essentially 1:1 correlation between the two systems with regard to first signs of incapacitation, collapse, and death from pyrolysis effluents from polycarbonate. It is hypothesized that similarly good correlations between these two systems might exist for other materials exhibiting predominantly carbon monoxide mechanisms of intoxication. This hypothesis needs to be confirmed, however, by additional experiments. Data with wool fabric exhibited greater variability with both procedures, indicating possibly different mechanisms of intoxication for wool as compared with bisphenol A polycarbonate.

Hilado, C. J.↗