Engineering Papers⌕ Search

Engineering topics

Hecht, Ethan

Publications and source records attributed to Hecht, Ethan.

At least 55 records · Page 3

Hydrogen Refueling Reference Station Lot Size Analysis for Urban Sites

Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) is a project initiated by the DOE in 2015 and executed by Sandia National Laboratories and the National Renewable Energy Laboratory to address R&D barriers to the deployment of hydrogen fueling infrastructure. One key barrier to the deployment of fueling stations is the land area they require (i.e. "footprint"). Space is particularly a constraint in dense urban areas where hydrogen demand is high but space for fueling stations is limited. This work presents current fire code requirements that inform station footprint, then identifies and quantifies opportunities to reduce footprint without altering the safety profile of fueling stations. Opportunities analyzed include potential new methods of hydrogen delivery, as well as alternative placements of station technologies (i.e. rooftop/underground fuel storage). As interest in heavy-duty fueling stations and other markets for hydrogen grows, this study can inform techniques to reduce the footprint of heavy-duty stations as well. This work characterizes generic designs for stations with a capacity of 600 kg/day hydrogen dispensed and 4 dispenser hoses. Three base case designs (delivered gas, delivered liquid, and on-site electrolysis production) have been modified in 5 different ways to study the impacts of recently released fire code changes, colocation with gasoline refueling, alternate delivery assumptions, underground storage of hydrogen, and rooftop storage of hydrogen, resulting in a total of 32 different station designs. The footprints of the base case stations range from 13,000 to 21,000 ft 2 . A significant focus of this study is the NFPA 2 requirements, especially the prescribed setback distances for bulk gaseous or liquid hydrogen storage. While the prescribed distances are large in some cases, these setback distances are found to have a nuanced impact on station lot size; considerations of the delivery truck path, traffic flow, parking, and convenience store location are also important. Station designs that utilize underground and rooftop storage can reduce footprint but may not be practical or economical. For example, burying hydrogen storage tanks underground can reduce footprint, but the cost savings they enable depend on the cost of burial and the cost land. Siting and economic analysis of station lot sizes illustrate the benefit of smaller station footprints in the flexibility and cost savings they can provide. This study can be used as a reference that provides examples of the key design differences that fueling stations can incorporate, the approximate sizes of generic station lots, and considerations that might be unique to particular designs.

08 HYDROGEN↗

Hydrogen Stations for Urban Sites

Additional fueling stations need to be constructed in the U.S. to enable the wide-spread adoption of fuel cell electric vehicles. A wide variety of private and public stakeholders are involved in the development of this hydrogen fueling infrastructure. Each stakeholder has particular needs in the station planning, development, and operation process that may include evaluation of potential sites and requirements, understanding the components in a typical system, and/or improving public acceptance of this technology. Publicly available templates of representative station designs can be used to meet many of these stakeholder needs. These 'Reference Stations' help reduce the cost and speed the deployment of hydrogen stations by providing a common baseline with which to start a design, enabling quick assessment of the suitability of a particular site for a hydrogen station, and identifying contributors to poor economics and research and development areas for certain station designs.

08 HYDROGEN↗

Validation of the AltRAM Physics Models for use with Compressed Natural Gas

The Alternative Fuels Risk Assessment Models (A1tRAM) toolkit combines Quantitative Risk Assessment (QRA) with simulations of unignited dispersion, ignited turbulent diffusion flames, and indoor accumulation with delayed ignition of fuels. The models of the physical phenomena need to be validated for each of the fuels in the toolkit. This report shows the validation for methane which is being used as a surrogate for natural gas. For the unignited dispersion model, seven previously published experiments from credible sources were used to validate. The validation looked at gas concentrations with respect to the distance from the release point. Four of these were underexpanded jets (i.e. release velocity equal to or greater than local speed of sound) and the other three subsonic releases. The methane plume model in AltRAM matched both varieties well, with higher accuracy for the underexpanded releases. For the jet flame model, we compared the heat flux and thermal radiation data reported from five separate turbulent jet flame experiments to the quantities calculated by A1tRAM. Four of the five datasets were for underexpanded diffusion jets flames. While the results still match well enough to give a good estimate of what is occurring, the error is higher than what was seen with the plume model. For the underexpanded flames A1tRAM provided reasonable approximations, which would lead to conservative risk assessments. Some modeling errors can be attributed to environmental effects (i.e. wind) since most large scale flame experiments are conducted outdoors. A1tRAM has been shown to be a reasonably accurate tool for calculating the concentration or flame properties of natural gas releases. Improvements could still be made for the plume of subsonic releases and radiative heat fluxes to reduce the conservative nature of these predictions. These models can provide valuable information for the risk assessment of natural gas infrastructure.

03 NATURAL GAS↗