Engineering topics
Hecht, Ethan
Publications and source records attributed to Hecht, Ethan.
INFLUENCE OF NON-EQUILIBRIUM CONDITIONS ON LIQUID HYDROGEN STORAGE TANK BEHAVIOR.
Abstract not provided.
Analysis to support revised distances between bulk liquid hydrogen systems and exposures.
Abstract not provided.
Effect of wind on cryogenic hydrogen dispersion from vent stacks.
Abstract not provided.
Hydrogen Risk Assessment Models (HyRAM) (V.3.1) (Technical Reference Manual)
The HyRAM software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of hydrogen safety, hazards, and risk. HyRAM includes generic probabilities for hydrogen equipment failures, probabilistic models for the impact of heat flux on humans and structures, and experimentally validated first-order models of hydrogen release and flame physics. HyRAM integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing hydrogen hazards (thermal effects from jet res, overpressure effects from deflagrations), and assessing impact on people and structures. HyRAM is developed at Sandia National Laboratories for the U.S. Department of Energy to increase access to technical data about hydrogen safety and to enable the use of that data to support development and revision of national and international codes and standards. HyRAM is a research software in active development and thus the models and data may change. This report will be updated at appropriate developmental intervals. This document provides a description of the methodology and models contained in HyRAM version 3.1. There have been several impactful updates since version 3.0. HyRAM 3.1 contains a correction to use the volume fraction for two-phase speed of sound calculations; this only affects cryogenic releases in which two-phase ow (vapor and liquid) is predicted in the orifice. Other changes include clarifications that inputs for tank pressure should be given in absolute pressure, not gauge pressure. Additionally, the interface now rejects invalid inputs to probability distributions, and the less accurate single-point radiative source model selection was removed from the interface.
Scientific justification for updating the bulk liquid separation distance tables in NFPA 2.
Abstract not provided.
Experiments and Analysis in Support of Science-Based Liquid Hydrogen Codes and Standards.
Abstract not provided.
Dispenser Reliability: Materials R&D. A Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Report
Dispensers are the top cause of maintenance events and down-time at hydrogen fueling stations. In an effort to help characterize and enable improvements in dispenser reliability, an extensive accelerated lifetime testing set-up was designed and built at NREL involving components typically part of dispensing operations at fueling stations. Device Under Test (DUTs) included different components such as normally open valves, normally closed valves, fueling nozzles, breakaways devices and filters. Conditions of testing included pressures, and flow rates similar to light duty fuel cell electric vehicles fueling at -40°C, and -20°C for thousands of cycles in hydrogen. Tested components (failed and non-failed) were disassembled at SNL and polymeric O-rings were carefully retrieved and cataloged for chemical and physical characterization. Data collected was compared to similar O-rings from unexposed or non-tested components for hydrogen effects, and failure modes. Degradation analyses, based on select polymer chemistries common across all component types, their location within components, visual assessment of damage coupled with strong hydrogen effects from chemical characterization, was completed and presented to NREL and DOE. Overall, the failure rate amongst the components was not as high as expected for the test conditions. Among the component types tested, breakaways were the most susceptible to damage under these test conditions, with fueling nozzles a close second. The proper combination of selection of the right polymer and optimum component design was found to make a strong difference in component reliability under severe dispenser operating conditions. Physical degradation of polymers, rather than chemical changes due to low temperature hydrogen exposure, is more prevalent as failure mode for these test conditions. The nature and the extent of the degradation was much less at -20°C as compared to -40°C. The damage and failure rates were higher at lower temperatures than at higher test temperatures. As expected, increasing the number of cycles at the lowest test temperature (-40°C) increased damage. This indicates that cycling at the low temperature of -40°C required by SAE J2601 can reduce component life in fuel dispensing operations
Developing a scientific basis for liquid hydrogen safety codes and standards in the United States.
Abstract not provided.
Session: Progress in Safety Research Topic: Low T (LH2/cryogenic) related.
Abstract not provided.
Computational fluid dynamics analysis of char conversion in Sandia’s pressurized entrained flow reactor
Design and analysis of practical reactors utilizing solid feedstocks rely on reaction rate parameters that are typically generated in lab-scale reactors. Evaluation of the reaction rate information often relies on assumptions of uniform temperature, velocity, and species distributions in the reactor, in lieu of detailed measurements that provide local information. This assumption might be a source of substantial error, since reactor designs can impose significant inhomogeneities, leading to data misinterpretation. Spatially resolved reactor simulations help understand the key processes within the reactor and support the identification of severe variations of temperature, velocity, and species distributions. In this work, Sandia’s pressurized entrained flow reactor is modeled to identify inhomogeneities in the reaction zone. Tracer particles are tracked through the reactor to estimate the residence times and burnout ratio of introduced coal char particles in gasifying environments. The results reveal a complex mixing environment for the cool gas and particles entering the reactor along the centerline and the main high-speed hot gas reactor flow. Furthermore, the computational fluid dynamics (CFD) results show that flow asymmetries are introduced through the use of a horizontal gas pre-heating section that connects to the vertical reactor tube. Computed particle temperatures and residence times in the reactor differ substantially from the idealized plug flow conditions typically evoked in interpreting experimental measurements. Furthermore, experimental measurements and CFD analysis of heat flow through porous refractory insulation suggest that for the investigated conditions (1350 °C, <20 atm), the thermal conductivity of the insulation does not increase substantially with increasing pressure.