Engineering Papers⌕ Search

Engineering topics

Geist, William H.

Publications and source records attributed to Geist, William H..

At least 19 records

AWCC Simulations

Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Evaluation of the Fast-Neutron Passive Collar (FNPC) Performance and Comparison with Scintillation Based Collars

This report describes a new method for the verification of fresh low enrichment uranium (LEU) fuel assemblies that can reduce International Atomic Energy Agency (IAEA) inspection time in the field and be completely independent of operator declared burnable poison content. The passive measurement makes unattended mode operation practical, and thus provides the potential for reducing inspector time in the field for future applications. The new simplified passive neutron measurement uses the 238 U spontaneous fission in LEU fresh fuel rods to self-interrogate the 235 U mass in the neighboring rods. The measured response increases linearly with the increase in the linear density (LD) of 235 U. The relatively high efficiency of the passive neutron detector (24%) provides good statistical precision (~ 2%) for the singles, doubles, and triples counting rates in the thermal-neutron mode. The three observables makes possible multiplicity analysis so that both the 235 U LD and the effective burnable poison content can be determined independent of the operator declarations. This closes the potential diversion path of miss-declaration the burnable poison content. This report presents the detector design, the as-built system, the detector parameter measurements, the calibration, and the assay uncertainty estimates. The calibration measurements were performed using the Los Alamos Laboratory mockup PWR fuel assembly. The measurements were made in both the fastneutron mode (with Cd/Gd metal liners) and the thermal-neutron mode (no Cd/Gd liners).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental Evaluation of the Fast-Neutron Passive Collar (FNPC) Performance (Interim Report)

This report represents a deliverable in the Safeguards Technology WBS # Project Title, 24.1.3.1, Task 3 (Report on laboratory-based performance testing of the FNPC). A new, simplified method for the verification of the 235 U mass in fresh LEU fuel assemblies that is relatively independent of burnable poison content is being developed. LWR fresh fuel is currently verified using the uranium neutron coincidence collar (UNCL), which relies on an AmLi source to induce fission in the 235 U. AmLi neutrons are slowed down in polyethylene, so the induced fission is primarily due to thermal neutrons. Burnable poisons, which are added to nuclear fuel assemblies to extend the lifetime of the fuel, absorb neutrons that would otherwise have induced fission in the fuel, thereby reducing the neutron count rate and thus the measured 235 U mass. To remove this bias factor a correction is applied based on the operator’s declared burnable poison content. The new technique uses 238 U spontaneous fission in LWR fresh fuel rods to self-interrogate the 235 U mass. The 238 U spontaneous fission neutrons have a hard neutron energy spectrum, which means that the technique is less sensitive to burnable poisons than the AmLi based systems. This project has continued the work done over the past two years to study this new technique using the optimized 3 He based fastneutron passive collar (FNPC). Fabrication of the FNPC has been completed and measurements are in progress using the LANL mockup PWR fuel assembly. Also, preliminary evaluations of advanced analysis techniques and unattended mode operation have been performed. In FY18, the 3 He tube based detector was compared with a 10 B sealed cell based detector for the same set of PWR fuel assemblies in the Rodeo-II program. The results were that the optimized 3 He detector had higher efficiency and less weight than the 10 B based system where both systems had about the same cost. Thus, the FY19 work continued exclusively with the 3 He based detector; although, either system had the potential for future applications. However, the high efficiency of the FPNC (~24%) is critical for precise measurements of the triples rate necessary in the multiplicity advanced analysis technique which can solve for the burnable poison content.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast Neutron Passive Collar Optimization Report

The UNCL has been used for over thirty years for the verification of the 235 U content of LWR nuclear fuel.The most recent version of the detector, the UNCL-II, consists of four HDPE blocks, three containing 3He proportional counters and a fourth containing a slot for an AmLi source. [1] The 3He proportional counters have a nominal active length of 33 cm, a diameter of 2.54 cm and a gas pressure of 4 atm. The UNCL-II has cavity dimensions 41.4 x 23.4 x 23.4 cm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A new method to measure the U-235 content in fresh LWR fuel assemblies via fast-neutron passive self-interrogation

The purpose of this paper is to provide a solution to a decades old safeguards problem in the verification of the fissile concentration in fresh light water reactor (LWR) fuel assemblies. The problem is that the burnable poison (e.g. Gd 2 O 3 ) addition to the fuel rods decreases the active neutron assay for the fuel assemblies. This paper presents a new innovative method for the verification of the 235 U linear mass density in fresh LEU fuel assemblies that is insensitive to the burnable poison content. The technique makes use of the 238 U atoms in the fuel rods to self-interrogate the 235 U mass. The innovation for the new approach is that the 238 U spontaneous fission (SF) neutrons from the rods induces fission reactions (IF) in the 235 U that are time correlated with the SF source neutrons. Thus, the coincidence gate counting rate benefits from both the nu-bar of the 238 U SF (2.07) and the 235 U IF (2.44) for a fraction of the IF reactions. Whereas, the 238 U SF background has no time-correlation boost. The higher the detection efficiency, the higher the correlated boost because background neutron counts from the SF are being converted to signal doubles. This time-correlation in the IF signal increases signal/background ratio that provides a good precision for the net signal from the 235 U mass. The hard neutron energy spectrum makes the technique insensitive to the burnable poison loading where a Cd or Gd liner on the detector walls is used to prevent thermal-neutron reflection back into the fuel assembly from the detector. Here, we have named the system the fast-neutron passive collar (FNPC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrations of Neutron Assay Systems

The purpose of this project is to to provide participants with a demonstration on how various neutron NDA assay systems are used to assay nuclear material in the field.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IAEA Sampling Plan

The objectives for this presentation are to describe the method that the IAEA uses to determine a sampling plan for nuclear material measurements; describe the terms detection probability and significant quantity; list the three nuclear materials measurement types; describe the sampling method applied to an item facility; and describe multiple method sampling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Boron-lined parallel-plate Collar

This report presents boron-lined parallel plate technology features, experimental benchmarking of initial MCNP model, and parallel-plate UNCL collar optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

U/Pu Analysis with Gamma-Ray Spectroscopy

This report presents an overview of the nuclear materials for the international workshop on nuclear, material forensics methodologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measuring SNM Isotopic Distributions using FRAM

The first group of slides provides background information on the isotopic composition of plutonium. It is shown that 240 Pu is the critical isotope in neutron coincidence/multiplicity counting. Next, response function analysis to determine isotopic composition is discussed. The isotopic composition can be determined by measuring the net peak counts from each isotope and then taking the ratio of the counts for each isotope relative to the total counts for the element. Then FRAM (Fixed energy Response function Analysis with Multiple efficiencies) is explained. FRAM can control data acquisition, automatically analyze newly acquired data, analyze previously acquired data, provide information on the quality of the analysis, and facilitate analysis in unusual situations (non-standard energy calibrations, gamma rays from non-SNM isotopes, poor spectra (within limits)).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplicity Counting

This set of slides begins by giving background and a review of neutron counting; three attributes of a verification item are discussed: 240 Pu eff mass; α, the ratio of (α,n) neutrons to spontaneous fission neutrons; and leakage multiplication. It then takes up neutron detector systems – theory & concepts (coincidence counting, moderation, die-away time); detector systems – some important details (deadtime, corrections); introduction to multiplicity counting; multiplicity electronics and example distributions; singles, doubles, and triples from measured multiplicity distributions; and the point model: multiplicity mathematics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗