Engineering Papers⌕ Search

Engineering topics

Fu, Yangyang

Publications and source records attributed to Fu, Yangyang.

At least 37 records · Page 2

Learning-based framework for sensor fault-tolerant building HVAC control with model-assisted learning

As people spend up to 87% of their time indoors, intelligent Heating, Ventilation, and Air Conditioning (HVAC) systems in buildings are essential for maintaining occupant comfort and reducing energy consumption. These HVAC systems in smart buildings rely 'on real-time sensor readings, which in practice often suffer from various faults and could also be vulnerable to malicious attacks. Such faulty sensor inputs may lead to the violation of indoor environment requirements (e.g., temperature, humidity, etc.) and the increase of energy consumption. While many model-based approaches have been proposed in the literature for building HVAC control, it is costly to develop accurate physical models for ensuring their performance and even more challenging to address the impact of sensor faults. In this work, we present a novel learning-based framework for sensor fault-tolerant HVAC control, which includes three deep learning based components for 1) generating temperature proposals with the consideration of possible sensor faults, 2) selecting one of the proposals based on the assessment of their accuracy, and 3) applying reinforcement learning with the selected temperature proposal. Moreover, to address the challenge of training data insufficiency in building-related tasks, we propose a model-assisted learning method leveraging an abstract model of building physical dynamics. Through extensive experiments, we demonstrate that the proposed fault-tolerant HVAC control framework can significantly reduce building temperature violations under a variety of sensor fault patterns while maintaining energy efficiency.

Xu, Shichao↗

Generalizing Similarity Laws for Radio-Frequency Discharge Plasmas across Nonlinear Transition Regimes

We generalize similarity theory based on the scaling and solution invariance of the Boltzmann equation, coupled with the Poisson equation, and demonstrate similarity laws for radio-frequency (rf) discharge plasmas across three nonlinear transitional regimes, namely, the alpha-gamma mode transition, the stochastic-Ohmic-heating mode transition, and the bounce-resonance-heating mode transition. Fundamental plasma parameters, e.g., the electron power absorption, under similar discharge conditions are examined via fully kinetic particle-in-cell simulations, and electron-kinetic invariance is exemplified in similar rf discharge plasmas. The results unambiguously confirm the applicability of similarity laws for rf plasmas in extended operating regimes, and strengthen the foundations and framework of similarity physics with universality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

A hardware-in-the-loop approach for laboratory performance verification of flexible building equipment in a typical commercial building

The overall objective of the project is to develop datasets that measure the holistic load flexibility performance of a suite of commonly-used commercial building HVAC and thermal storage equipment using a hardware-in-the-loop test method. The development of the software side of the hardware-in-the-loop flexible load testbed is summarized in this paper.

Chen, Zhelun↗

Direct current microplasma formation around microstructure arrays

We demonstrate the formation and transition behaviors of a microplasma around microstructure arrays at different gas pressures via two-dimensional particle-in-cell/Monte Carlo collision simulations. It is found that the microdischarge occurs outside the cathode microcavities at the lowest pressure and starts penetrating the microcavities with a curved sheath edge as the pressure increases. At higher pressure, coupled periodic microhollow cathode discharges (MHCDs) are formed inside the microcavities. Further increasing the gas pressure results in the disappearance of the MHCDs, and the dominant discharge shifts outside of the microcavity, locating above the protrusion tips. The effect of the space charge shielding on the discharge and the conditions for MHCD formation are discussed. The macroscopic discharge parameter scalings with the gas pressure and the electron kinetics are also examined. The results are helpful for deeply understanding the microplasma formation with nonplanar electrodes, which inform the scaling, design, and optimization of microplasma array devices across a wide range of pressure regimes in practical applications.

42 ENGINEERING↗

Improving Data Center Energy Efficiency Through End-to-End Cooling Modeling and Optimization. Final Report

This report summarizes the development and demonstration of the three features developed for the DOE project “Improving Data Center Energy Efficiency through End-to-End Cooling Modeling and Optimization” (Award No. DE-EE0007688). The development of the three software features, Feature 1: Optimization of Cooling System Operation, Feature 2: Optimization of Airflow Management System, and Feature 3: Simultaneous Optimization of Airflow Management and Cooling Systems, are described first. Feature 1 is implemented in Phase 1 of the project and demonstrates 15% energy savings from cooling system optimization by applying the proposed retrofit solutions. Feature 2 is implemented in Phase 2 and the assessments show cooling energy-saving potential between 19.3% and 54.0%, depending on the energy-saving measures employed. In addition, investigating the energy saving potential for a hypothetical simple data center shows about 6.8% energy savings by optimizing the server load placement. Feature 3 is implemented in Phase 3 and the results show energy savings of 53.4% and 74.6% for the two partner data centers, respectively, compared to the baselines defined in Phase 1. Lastly, the project outcomes including software releases and publications are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of machine learning in building load prediction

The surge of machine learning in recent years has been empowering engineer modeling in various fields. The decreasing hardware cost, increasing data accessibility, and advances of building automation system (BAS) allow the collection and storage of a significant amount of building operation data. The two facts provide great opportunities of applying machine learning to building energy systems modeling and analysis. There are a great number of research papers on this topic but there lacks a comprehensive and general review to summarize the current development, limitations, gaps and future trend. In this review paper series, machine learning techniques in building energy system modeling and analysis are reviewed under the organization and logic of the machine learning definition by Tom M. Mitchell: a computer program is said to learn from experience E with respect to some class of tasks T and performance measure P if its performance at tasks in T, as measured by P, improves with experience E. This paper is the first part of the review paper series, which focuses on building load prediction. First, the applications of building load prediction model (task T) are reviewed. Then, the modeling algorithms improving machine learning performance and accuracy (performance P) are reviewed. At the same time, the literature on the data perspective for modeling (experience E), including data engineering from sensors level to data level, pre-processing, feature extraction and selection, is reviewed. Finally, what is well-studied and what is lacking but with great potential are concluded; the gaps between present and future utilization of machine learning techniques are identified; the future trend and development are also predicted. The target readers of this paper are not only researchers from the building side who can get exposed to cutting edge machine learning tools, but also those from machine learning side who can understand the potential and challenge to apply machine learning in buildings.

Liang, Zhang↗

Comparison of 1D and 2D particle-in-cell simulations for DC magnetron sputtering discharges

One-dimensional and two-dimensional particle-in-cell (PIC)/Monte Carlo collision simulations are performed for a balanced direct current magnetron sputtering (DCMS) discharge. The plasma parameters obtained by both simulations above the target racetrack share similar features and magnitudes under similar discharge intensities, i.e., similar local discharge current densities. The commonly observed high-energy tail of electron energy distribution in DCMS discharges is reproduced in both simulations. Additionally, the accuracy and applicability of using onedimensional simulations to qualitatively investigate the characteristics of balanced DCMS discharge are confirmed. In terms of capturing the key physical mechanisms in DCMS, one-dimensional PIC simulation is an efficient method, which could largely alleviate the computational expense and preserve the physical fidelity of modeling results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transition characteristics and electron kinetics in microhollow cathode discharges

We demonstrate the transition characteristics and electron kinetics of microdischarges in a microgap with a cathode having microstructures using two-dimensional particle-in-cell/Monte Carlo collision (2d3v) simulations. It is found that the microdischarge is inside the hollow cavity at lower pressures, forming microhollow cathode discharges (MHCDs), while the dominant discharge moves outside the cavity at higher pressures, locating above the cathode rectangular protrusion tip. The spatial distributions of the microdischarge parameters (e.g., electric potential and electron density) are presented by capturing the transition characteristics. The electron kinetics of the microdischarges are examined based on the moment analysis of the electron Boltzmann equation. The collisional and non-collisional components of the electron power absorption are decomposed, which were seldomly investigated for microdischarges previously. The results provide fundamental insights into MHCD formation with a structured electrode at varying pressure conditions, which could be beneficial for the design and fabrication of microplasma devices in practical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transitions between electron emission and gas breakdown mechanisms across length and pressure scales

This Perspective outlines theoretical, simulation, and experimental studies linking electron emission and gas breakdown. Many studies have investigated field emission-driven microscale gas breakdown, including recent reviews [Garner et al., IEEE Trans. Plasma Sci. 48, 808–824 (2020); Fu et al., Plasma Res. Express 2, 013001 (2020)]. This Perspective focuses on generalizing field emission-driven microscale gas breakdown to consider the contribution of other forms of electron emission, specifically thermionic and space-charge limited. Recent theoretical studies have unified thermionic, field, and space-charge limited emission with and without collisions to derive “nexuses” where the individual solutions match, indicating transitions in the mechanisms. Reducing device size to nanoscale at atmospheric pressure leads to a transition from field emission to space-charge limited emission for nitrogen at ~250 nm. This Perspective summarizes the derivation of these nexuses and future extensions. We next describe simulation and theoretical studies for field emission-driven microscale gas breakdown and highlight how the nexus theory may be integrated to account for temperature, space-charge, and pulse parameters. Finally, we summarize the development of optical techniques to assess microscale gas breakdown and recent nanoscale experiments at atmospheric pressure that suggest that space-charge may begin to contribute to field emission prior to gas breakdown. We highlight the combination of theory, simulation, and experiment to link electron emission and gas breakdown mechanisms across length, pressure, and temperature scales for applications that include vacuum electronics, pulsed power, and medicine.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Benchmark of the KGMf with a coupled Boltzmann equation solver

The Kinetic Global Model framework (KGMf) is an open-source general-purpose global model (spatially averaged) simulation code developed to explore the reaction kinetics and pathways in plasma discharge systems. It contains species continuity and electron energy balance equations, with a time-dependent evaluated electron energy distribution function (EEDF) for electron impact reactions. The EEDF is utilized to determine the rate coefficients for electron impact reactions, which can have profound impact on the temporal evolutions of plasma parameters. Previously, the EEDF was commonly assumed as Maxwellian or an analytical function of the effective electron temperature. In this work, the KGMf is coupled with a Boltzmann equation (BE) solver to self-consistently compute the EEDF. The EEDF evolution frequency is determined based on relative changes of the reduced electric field. The KGMf is benchmarked with the ZDPlasKin code based on high-pressure low-temperature argon plasma discharge cases. Additionally, the temporal evolutions of reduced electric field, electron temperature, EEDF, reaction rates, and species densities, are obtained and compared under different discharge conditions, showing good agreement between the KGMf and the ZDPlasKin simulations. The application of the KGMf for predicting breakdown times in high power microwave discharges is also presented, which shows qualitative agreement with particle-in-cell simulations. The KGMf can be further applied for more complicated plasma discharge systems, where the reaction kinetics are more intricate (e.g., plasma-assisted combustion systems).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Topology Optimization Framework to Facilitate Adoption of Advanced District Thermal Energy Systems

Advanced district thermal energy systems, which circulate water at temperatures near ambient conditions, and facilitate the utilization of waste heat and renewable thermal sources, can lower the carbon-intensity of urban districts, advancing the U.N. Sustainable Development Goals. Optimization of the network topology — the selection of the best subset of buildings and the best network to connect them, to minimize life cycle cost — can increase adoption of these system in appropriate applications. The potential "solution space" of the topology optimization problem grows factorially with the number of buildings in the district, motivating the consideration of a design heuristic. In this study, a heuristic for the network selection was evaluated with an exhaustive search, for a prototypical four-building district. For the prototypical district considered, the heuristic was effective in selecting an optimal network topology. Additionally, it was found that, in this case, the selection of the subset of buildings was more influential on the life cycle cost than the selection of the network topology. This work is part of a larger effort to develop a topology optimization framework for district thermal energy systems, which is anticipated to address barriers to adoption of ambient-temperature systems.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Similarity law and frequency scaling in low-pressure capacitive radio frequency plasmas

We verify the similarity law (SL) and show a violation of frequency scaling (f-scaling) in low-pressure capacitive radio frequency (rf) plasmas via fully kinetic particle-in-cell simulations. The SL scaling relations for electron density and electron power absorption are first confirmed in similar rf discharges. Based on these results, with only the driving frequency varied, the f-scaling for electron density is also validated, showing almost the same trend as the SL scaling, across most of the frequency regime. However, violations of the f-scaling are observed at lower frequencies, which are found to be relevant to the electron heating mode transition from stochastic to Ohmic heating. Electron kinetic invariance is illustrated for the SL and f-scaling being valid, respectively, whereas the electron kinetic variation is observed when the f-scaling is violated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Similarity of capacitive radio-frequency discharges in nonlocal regimes

Similarity transformations are essential for correlating discharges at different scales, which are mostly utilized with local field or local energy approximations. In this work, we report the fully kinetic results from particle-in-cell/Monte Carlo collision simulations that unambiguously demonstrate the similarity of radio frequency (rf) discharges in nonlocal regimes where the electron energy relaxation length is much larger than the gap dimension. It is found that at a constant rf voltage amplitude, discharges will be similar if the gas pressure, inverse of gap distance, and rf driving frequency are all changed by the same scaling factor. The scaling relations of fundamental parameters are illustrated for rf discharges in the alpha-mode with secondary electron emission ignored, and the temporal electron kinetics are shown to have invariance in similar discharges. The results explicitly validate the scaling laws in nonlocal kinetic regimes, indicating promising application potentials of the similarity transformations across a wide range of kinetic regimes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-energy ballistic electrons in low-pressure radio-frequency plasmas

This study demonstrates the presence of a small number of high-energy ballistic electrons (HEBEs) that originate from secondary electrons in low-pressure radio-frequency (rf) plasmas. The kinetic behaviors of the HEBEs are illustrated through electron energy probability functions from the fully kinetic particle-in-cell simulations, showing two wavy high-energy tails and two bifurcations during one rf cycle. Test-particle simulations and a semi-analytical method associated with nonlocal electron kinetics are performed to characterize the HEBE trajectories, which reveal the ballistic nature of the HEBEs and their typical bouncing features between the rf sheaths. Parameter dependence of the HEBEs on the discharge conditions (e.g., gas pressure, gap distance, and rf frequency) are identified, which is relevant to the plasma collisionality. With a pronounced presence of HEBEs, the overall impacts of the secondary electron emission on discharge parameters, such as electron power absorption and ionization rate, are also illustrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessments of data centers for provision of frequency regulation

There are numerous opportunities for data centers to participate in demand response programs considering their large energy capacities, flexible working environments and workloads, redundant design and operation, etc. As a type of demand response, frequency regulation requires fast response, and its potential is not fully explored by data centers yet. This paper proposes a synergistic control strategy for data center frequency regulation which uses both IT and cooling systems. It combines power management techniques at the server level with control of the chilled water supply temperature to track the regulation signal from the electrical market. A frequency regulation flexibility factor is also proposed to increase the IT capacity for frequency regulation. The performance of the control strategy is studied through numerical simulations using an equation based object-oriented Modelica platform designed for data centers. Simulation results show that with well-tuned control parameters, data centers can provide frequency regulation service in both regulation up and down. The performance of data centers in providing frequency regulation service is largely influenced by the regulation capacity bid, frequency regulation flexibility factor, workload condition, and cooling mode of the cooling system, and not significantly influenced by the time constant of chillers. In addition, compared with a server-only control strategy, the proposed synergistic control strategy can provide an extra regulation capacity of 3% of the design power when chillers are activated. Here, when chillers are deactivated, both strategies have a similar regulation capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a topology analysis tool for fifth-generation district heating and cooling networks

Fifth generation district heating and cooling networks are characterized by supply temperatures in the ambient range of 15-25 degrees C, which not only reduces heat loss but also allows for integrating various kinds of low-temperature waste heat sources. The ability of these networks to absorb waste heat that is normally unrecoverable makes them an attractive solution for the future energy supply of urban areas. To enhance the adoption of these networks, this paper describes the development of a software tool to analyze the feasibility of fifth-generation of district heating and cooling systems in both new and existing districts. The research attempts to answer the question: 'Which buildings should be connected to a low-temperature hydraulic network given both the incremental benefits and costs relative to the scenario of decentralized (dedicated) heating and cooling systems for each building?' Therefore, all possible network layouts of the buildings are considered where the heating and cooling demands of each building are met by the fifth-generation of district heating and cooling network. For the heating and cooling load characterization of the buildings, reduced-order models are used while renewable energy and waste heat sources are included in the network. The focus of the research lies in the development of a hydraulic model for flexible use in the urban energy modeling and the optimization of the fifth-generation of district heating and cooling network topology for a given urban district. This research displays simulation results that quantify the performance of the fifth-generation of district heating and cooling network based on various output metrics, including primary energy usage, carbon dioxide emissions, and network implementation cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗